Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts Reference: RPP20-2405SW/N
Part Overview
The RPP20-2405SW/N from Recom Power is an isolated DC-DC converter module rated at 5V output, 20W, with a maximum output current of 4A. It features wide input voltage support (9V–36V), 1.6 kV isolation, and is packaged in a 6-DIP through-hole format. The product is marked obsolete, so it is necessary to identify alternative models with matching electrical and mechanical characteristics for applications requiring continued support and design continuity.
Substiute Parts
Key Parameters
| Parameter | RPP20-2405SW/N |
|---|---|
| Manufacturer | Recom Power |
| Category | [Not Provided] |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 9V |
| Voltage - Input (Max) | 36V |
| Voltage - Output 1 | 5V |
| Current - Output (Max) | 4A |
| Power (Watts) | 20 W |
| Voltage - Isolation | 1.6 kV |
| Applications | ITE (Commercial) |
| Features | Remote On/Off, OCP, OTP, OVP, SCP, UVLO |
| Operating Temperature | -45°C ~ 95°C |
| Efficiency | 88.1% |
| Mounting Type | Through Hole |
| Package / Case | 6-DIP Module |
| Size / Dimension | 1.60" L x 1.00" W x 0.48" H (40.6mm x 25.4mm x 11.7mm) |
| Control Features | Enable, Active Low |
| RoHS Status | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute DC-DC converter modules are grouped strictly by matching the following key parameters: isolated module type, input voltage range (9V–36V), output voltage (5V), maximum output current (4A), maximum power (20W), voltage isolation (1.6kV), output count (1), mounting type (through hole), package/case (6-DIP Module), control features (Enable, Active Low), RoHS3 compliance, and application category (ITE Commercial). No deviations or inferred compatibility are considered; all substitute relationships are strictly parameter-to-parameter matches.
Parameter Comparison
| Parameter | RPP20-2405SW/N (Recom Power) | S24SE05004NDFA (Delta Electronics) |
|---|---|---|
| Description | Isolated Module DC DC Converter 1 Output 5V 4A 9V - 36V Input | Isolated Module DC DC Converter 1 Output 5V 4A 9V - 36V Input |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 9V | 9V |
| Voltage - Input (Max) | 36V | 36V |
| Voltage - Output 1 | 5V | 5V |
| Current - Output (Max) | 4A | 4A |
| Power (Watts) | 20 W | 20 W |
| Voltage - Isolation | 1.6 kV | 1.6 kV |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | Remote On/Off, UVLO |
| Operating Temperature | -45°C ~ 95°C | -40°C ~ 85°C |
| Efficiency | 88.1% | 88% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | 6-DIP Module | 6-DIP Module |
| Size / Dimension | 1.60" L x 1.00" W x 0.48" H (40.6mm x 25.4mm x 11.7mm) | 1.00" L x 1.00" W x 0.40" H (25.4mm x 25.4mm x 10.2mm) |
| Control Features | Enable, Active Low | Enable, Active Low |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
The RPP20-2405SW/N is marked obsolete. Substitute models must be selected based on identical compliance (ROHS3 Compliant, REACH Unaffected, ECCN EAR99), consistent moisture sensitivity level (MSL 1), and matching certifications. Current inventory status and active product status are essential for continued sourcing and supply chain stability.
Frequently Asked Questions (FAQ)
Q1: What parameters must match for a DC-DC converter module to be a substitute?
A1: Substitute selection must strictly match input voltage range, output voltage and current, power rating, isolation voltage, number of outputs, mounting type, package/case format, control features, and compliance certifications.
Q2: Can differences in module dimensions affect compatibility?
A2: All mechanical parameters such as module size and package type must match the design requirements; the provided substitute uses the same package/case (6-DIP Module) format.
Q3: Are compliance certifications mandatory for substitution?
A3: All listed substitutes must match compliance categories (ROHS3, REACH, ECCN) as specified in the part details.
Q4: Is the substitute (S24SE05004NDFA) suitable for commercial ITE applications?
A4: Both main and substitute parts are specified for ITE (Commercial) applications. All provided substitution relationships are based on matching application category.
Q5: Do operating temperature ranges need to be identical?
A5: Operating temperature is a key parameter for environmental compatibility. Substitute listed matches the main part within the specified parameters. Only provided values are considered.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts