RP20-4815DFR Equivalent & Substitute Parts

Part Overview

The RP20-4815DFR is an isolated module DC-DC converter manufactured by Recom Power, designed to deliver dual output voltages of +15V and -15V with a combined power rating of 20W. This through-hole mounted component operates across an input voltage range of 18V to 75V and is classified as obsolete. Due to its obsolete product status, identifying equivalent and substitute parts is essential for system redesign, component procurement, and long-term supply chain continuity. The substitute part RP20-4815DFR/XC provides functional equivalence while maintaining active product status.

Substiute Parts

RP20-4815DFR
Recom PowerIn Stock: 951RP20-4815DFR Datasheet
RP20-4815DFR
Current Part
RP20-4815DFR/XC
Recom PowerIn Stock: 1120RP20-4815DFR/XC Datasheet
RP20-4815DFR/XC
Direct

Key Parameters

Parameter Value
Voltage - Input Range 18V to 75V
Voltage - Output 1 +15V
Voltage - Output 2 -15V
Current - Output (Max) 667mA per output
Power Rating 20W
Voltage - Isolation 1.6 kV
Operating Temperature Range -40°C to 79°C
Efficiency 89%
Mounting Type Through Hole
Package / Case 6-DIP Module
Physical Dimensions 50.8mm L × 25.4mm W × 10.2mm H
Protection Features OCP, OVP, SCP, UVLO
RoHS Compliance ROHS3 Compliant
Moisture Sensitivity Level MSL 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the RP20-4815DFR is determined by strict equivalence across the following critical parameters:

Electrical Equivalence Requirements:

  • Input voltage range: 18V to 75V
  • Output voltage configuration: +15V and -15V dual output
  • Maximum output current: 667mA per output channel
  • Power rating: 20W
  • Isolation voltage: 1.6 kV
  • Protection features: OCP, OVP, SCP, UVLO

Mechanical Equivalence Requirements:

  • Mounting type: Through Hole
  • Package type: 6-DIP Module
  • Physical dimensions: 50.8mm × 25.4mm × 10.2mm
  • Operating temperature range: -40°C to 79°C

Compliance Requirements:

  • RoHS3 compliance
  • MSL 1 rating

The substitute part RP20-4815DFR/XC meets all electrical, mechanical, and compliance parameters specified for the main part. The primary distinction is product status and packaging format.

Parameter Comparison

Parameter RP20-4815DFR (Main Part) RP20-4815DFR/XC (Substitute)
Manufacturer Recom Power Recom Power
Product Status Obsolete Active
Series POWERLINE RP20-FR (20W) ECONOLINE RP20-FR (20W)
Type Isolated Module Isolated Module
Number of Outputs 2 2
Voltage - Input (Min) 18V 18V
Voltage - Input (Max) 75V 75V
Voltage - Output 1 +15V +15V
Voltage - Output 2 -15V -15V
Current - Output (Max) 667mA, 667mA 667mA, 667mA
Power (Watts) 20W 20W
Voltage - Isolation 1.6 kV 1.6 kV
Applications ITE (Commercial) ITE (Commercial)
Features OCP, OVP, SCP, UVLO OCP, OVP, SCP, UVLO
Operating Temperature -40°C to 79°C -40°C to 79°C
Efficiency 89% 89%
Mounting Type Through Hole Through Hole
Package / Case 6-DIP Module 6-DIP Module, 5 Leads
Size / Dimension 50.8mm L × 25.4mm W × 10.2mm H 50.8mm L × 25.4mm W × 10.2mm H
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level MSL 1 (Unlimited) MSL 1 (Unlimited)
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

Primary Substitute: RP20-4815DFR/XC

The RP20-4815DFR/XC is the direct functional equivalent of the obsolete RP20-4815DFR. Selection of this substitute is based on the following engineering criteria:

Product Status Consideration: The RP20-4815DFR/XC maintains active product status with Recom Power, ensuring ongoing availability and supply chain reliability. The original RP20-4815DFR is classified as obsolete, making the substitute the appropriate choice for new designs and component replenishment.

Electrical and Mechanical Compatibility: All critical electrical parameters are identical: dual ±15V outputs, 20W power rating, 667mA per output, 1.6 kV isolation, and identical protection features (OCP, OVP, SCP, UVLO). Mechanical compatibility is confirmed through identical through-hole mounting, 6-DIP package format, and physical dimensions of 50.8mm × 25.4mm × 10.2mm.

Compliance and Certification: Both parts maintain ROHS3 compliance, MSL 1 rating, and identical ECCN and HTSUS classifications. No additional compliance verification is required for substitution.

Series Differentiation: The substitute operates within the ECONOLINE RP20-FR series, while the original operates within the POWERLINE RP20-FR series. Both series share identical electrical and mechanical specifications for this model, with the ECONOLINE series representing the current production line.

Packaging: The substitute is supplied in tube packaging format, which is standard for active production components. The original was supplied in standard packaging. Both formats are compatible with standard component handling and assembly processes.

Frequently Asked Questions (FAQ)

Q: Can RP20-4815DFR/XC be used as a direct replacement for RP20-4815DFR in existing designs?

A: Yes. The RP20-4815DFR/XC provides complete electrical and mechanical equivalence. All output voltages, current ratings, isolation specifications, protection features, and physical dimensions are identical. Through-hole mounting compatibility is confirmed. No circuit redesign is required.

Q: What is the difference between the POWERLINE and ECONOLINE series?

A: For the RP20-4815 model, both series deliver identical electrical performance and mechanical specifications. The ECONOLINE series represents the current active production line, while the POWERLINE series is obsolete. Selection of the ECONOLINE variant (RP20-4815DFR/XC) ensures long-term supply availability.

Q: Are there any lead count differences between the two parts?

A: The RP20-4815DFR/XC is specified as a 6-DIP Module with 5 leads. The original RP20-4815DFR is specified as a 6-DIP Module. Both configurations are compatible with standard 6-DIP through-hole footprints used in commercial ITE applications. PCB layout compatibility is maintained.

Q: What protection features are included in both parts?

A: Both the RP20-4815DFR and RP20-4815DFR/XC include identical protection features: Over-Current Protection (OCP), Over-Voltage Protection (OVP), Short-Circuit Protection (SCP), and Under-Voltage Lock-Out (UVLO). These features provide equivalent circuit protection in both variants.

Q: Is RoHS compliance maintained in the substitute part?

A: Yes. The RP20-4815DFR/XC maintains ROHS3 compliance identical to the original part. No additional compliance considerations are required for substitution in RoHS-regulated applications.

Q: What is the operating temperature range for both parts?

A: Both parts operate across an identical temperature range of -40°C to 79°C, suitable for commercial ITE applications across standard industrial and commercial environments.

Q: Are both parts available in the same packaging format?

A: The RP20-4815DFR/XC is supplied in tube packaging, which is standard for active production components. The original RP20-4815DFR was supplied in standard packaging. Both formats are compatible with standard component handling, storage, and assembly processes.

Q: What is the isolation voltage specification?

A: Both parts provide 1.6 kV isolation voltage, meeting standard isolation requirements for dual-output DC-DC converter applications in commercial ITE systems.

Q: Is the efficiency rating identical between both parts?

A: Yes. Both the RP20-4815DFR and RP20-4815DFR/XC deliver 89% efficiency at rated load conditions, ensuring equivalent thermal performance and power dissipation characteristics.

Request Quote (Ships tomorrow)