Equivalent & Substitute Parts for RP10-2412DA-HC

Part Overview

The RP10-2412DA-HC from Recom Power is a DC-DC converter designed as an isolated module with dual outputs of +12V and -12V at a maximum output current of 416mA each, supporting an input voltage range of 18V to 36V. The device provides 10W output power, 1.6kV isolation, and features Over Current Protection (OCP), Over Voltage Protection (OVP), Short Circuit Protection (SCP), and Under Voltage Lock Out (UVLO). It is mounted through hole in a 6-DIP module case, sized at 1.00" x 1.00" x 0.65". The RP10-2412DA-HC is now obsolete, making it necessary to identify alternative models that match all electrical and mechanical specifications for continued design support or replacement.

Substiute Parts

RP10-2412DA-HC
Recom PowerIn Stock: 912RP10-2412DA-HC Datasheet
RP10-2412DA-HC
Current Part
RP10-2412DA/XC-HC
Recom PowerIn Stock: 782RP10-2412DA/XC-HC Datasheet
RP10-2412DA/XC-HC
Direct

Key Parameters

Manufacturer Part Number Manufacturer Description Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Voltage - Output 2 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status Moisture Sensitivity Level (MSL) ECCN HTSUS Product Status
RP10-2412DA-HC Recom Power DC DC CONVERTER +/-12V 10W Isolated Module 2 18V 36V 12V -12V 416mA, 416mA 10 W 1.6 kV ITE (Commercial) OCP, OVP, SCP, UVLO -40°C ~ 80°C 89% Through Hole 6-DIP Module 1.00" L x 1.00" W x 0.65" H ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9580 Obsolete

Substitute Part Grouping Explanation

The substitute part is selected based strictly on matching the following key parameters: electrical ratings (input voltage, output voltage, output current, output power, isolation), number of outputs, module type, package/case format, size/dimensions, mounting type, operating temperature range, application type, compliance parameters (RoHS), and protection features. Only parts that align precisely with these specifications are considered suitable substitutes.

Parameter Comparison

Manufacturer Part Number Manufacturer Description Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Voltage - Output 2 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status Moisture Sensitivity Level (MSL) ECCN HTSUS Product Status
RP10-2412DA-HC Recom Power DC DC CONVERTER +/-12V 10W Isolated Module 2 18V 36V 12V -12V 416mA, 416mA 10 W 1.6 kV ITE (Commercial) OCP, OVP, SCP, UVLO -40°C ~ 80°C 89% Through Hole 6-DIP Module 1.00" L x 1.00" W x 0.65" H ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9580 Obsolete
RP10-2412DA/XC-HC Recom Power DC DC CONVERTER +/-12V 10W Isolated Module 2 18V 36V 12V -12V 416mA, 416mA 10 W 1.6 kV ITE (Commercial) Remote On/Off, OCP, OVP, SCP, UVLO -40°C ~ 80°C 90% Through Hole 6-DIP Module, 5 Leads 1.00" L x 1.00" W x 0.65" H ROHS3 Compliant 1 (Unlimited) EAR99 8504.40.9580 Active

Engineering Selection Recommendations

The RP10-2412DA-HC is classified as obsolete. The RP10-2412DA/XC-HC serves as a direct substitute as it matches all key functional, mechanical, and regulatory parameters including RoHS3 compliance, operating temperature range, mounting type, package/case dimensions, and isolation voltage. Both parts have ECCN EAR99 and HTSUS 8504.40.9580. Selection of RP10-2412DA/XC-HC ensures continuity in design without deviation from previously validated compliance or certifications.

Frequently Asked Questions (FAQ)

Q1: What are the essential substitution criteria for RP10-2412DA-HC?
A1: Essential criteria include matching input voltage range (18V – 36V), output voltages (+12V, -12V), output currents (416mA each), power rating (10 W), isolation voltage (1.6 kV), type (Isolated Module), mechanical dimensions (1.00" x 1.00" x 0.65"), mounting type (Through Hole), package/case format, and regulatory compliance (RoHS3).

Q2: How can mechanical compatibility be ensured during substitution?
A2: Mechanical compatibility is ensured by selecting parts with identical mounting type, package/case (6-DIP Module), and dimensional specifications (1.00" L x 1.00" W x 0.65" H).

Q3: Are features such as protection and operating temperature considered in substitution?
A3: Yes, features like OCP, OVP, SCP, UVLO, and matching operating temperature (-40°C ~ 80°C) are included in the substitution criteria.

Q4: Is it necessary to verify regulatory certifications when selecting a substitute?
A4: For substitution, regulatory certifications including RoHS3 compliance, ECCN categorization, and HTSUS code alignment are strictly matched between the main and substitute part numbers.

Q5: What additional features are present in RP10-2412DA/XC-HC compared to RP10-2412DA-HC?
A5: RP10-2412DA/XC-HC includes Remote On/Off functionality in addition to the primary protection features (OCP, OVP, SCP, UVLO), with all other core substitution parameters aligned.

Request Quote (Ships tomorrow)