Request Quote
(Ships tomorrow)
RP10-1215DA-HC Equivalent & Substitute Parts
Part Overview
The RP10-1215DA-HC is an isolated module DC-DC converter manufactured by Recom Power, part of the POWERLINE RP10-A series. This 10W converter provides dual output voltages (+15V and -15V) from a 9V to 18V input range, delivering 333mA on each output channel. The device is designed for Information Technology Equipment (ITE) applications in commercial environments.
The RP10-1215DA-HC is classified as obsolete. Identifying equivalent and substitute parts is necessary to ensure continued availability for new designs, maintenance applications, and production continuity where this component is specified.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Input Voltage Range | 9V to 18V |
| Output Voltage 1 | +15V |
| Output Voltage 2 | -15V |
| Output Current (per channel) | 333mA |
| Power Rating | 10W |
| Isolation Voltage | 1.6 kV |
| Operating Temperature Range | -40°C to +80°C |
| Efficiency | 90% |
| Package Type | 6-DIP Module |
| Mounting Type | Through Hole |
| Physical Dimensions | 25.4mm × 25.4mm × 16.5mm |
| Protection Features | OCP, OVP, SCP, UVLO |
| RoHS Compliance | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitution of the RP10-1215DA-HC is determined by strict equivalence across the following critical parameters:
Electrical Compatibility Requirements:
- Input voltage range: 9V to 18V (minimum and maximum)
- Output voltage configuration: +15V and -15V dual output
- Output current capacity: 333mA per channel minimum
- Power rating: 10W
- Isolation voltage: 1.6 kV
- Operating temperature range: -40°C to +80°C
- Protection features: OCP, OVP, SCP, UVLO
Mechanical Compatibility Requirements:
- Package type: 6-DIP Module
- Mounting type: Through Hole
- Physical dimensions: 25.4mm × 25.4mm × 16.5mm
- Pin configuration and lead count
Compliance Requirements:
- RoHS3 compliance
- Moisture Sensitivity Level (MSL): 1
Parts meeting all these criteria are classified as direct substitutes. Variations in packaging format (such as Tray versus standard packaging) do not affect electrical or mechanical compatibility and do not preclude substitution.
Parameter Comparison
| Parameter | RP10-1215DA-HC (Main Part) | RP10-1215DA/XC-HC (Substitute) | Match Status |
|---|---|---|---|
| Manufacturer | Recom Power | Recom Power | Identical |
| Series | POWERLINE RP10-A (10W) | POWERLINE RP10-A (10W) | Identical |
| Input Voltage (Min) | 9V | 9V | Identical |
| Input Voltage (Max) | 18V | 18V | Identical |
| Output Voltage 1 | +15V | +15V | Identical |
| Output Voltage 2 | -15V | -15V | Identical |
| Output Current (Max) | 333mA, 333mA | 333mA, 333mA | Identical |
| Power Rating | 10W | 10W | Identical |
| Isolation Voltage | 1.6 kV | 1.6 kV | Identical |
| Operating Temperature | -40°C to +80°C | -40°C to +80°C | Identical |
| Efficiency | 90% | 90% | Identical |
| Package / Case | 6-DIP Module | 6-DIP Module, 5 Leads | Compatible |
| Mounting Type | Through Hole | Through Hole | Identical |
| Dimensions | 25.4mm × 25.4mm × 16.5mm | 25.4mm × 25.4mm × 16.5mm | Identical |
| Protection Features | OCP, OVP, SCP, UVLO | OCP, OVP, SCP, UVLO, Remote On/Off | Compatible (substitute has additional feature) |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | Identical |
| MSL Rating | 1 (Unlimited) | 1 (Unlimited) | Identical |
| Product Status | Obsolete | Active | Substitute is current production |
Engineering Selection Recommendations
The RP10-1215DA/XC-HC is a direct electrical and mechanical substitute for the RP10-1215DA-HC. All critical parameters—input voltage range, dual output voltages, output current capacity, power rating, isolation voltage, operating temperature range, and protection features—are identical between the two parts.
Key Selection Factors:
-
Product Status: The RP10-1215DA-HC is obsolete, while the RP10-1215DA/XC-HC is in active production. For new designs and ongoing procurement, the RP10-1215DA/XC-HC is the appropriate selection.
-
Compliance: Both parts are ROHS3 compliant and carry identical MSL ratings, ensuring regulatory and environmental compatibility.
-
Additional Features: The RP10-1215DA/XC-HC includes Remote On/Off functionality in addition to the standard protection features (OCP, OVP, SCP, UVLO) present in the main part. This additional feature does not compromise compatibility and may provide enhanced functionality for applications requiring remote control capability.
-
Packaging: The substitute part is supplied in Tray packaging, which is a standard distribution format and does not affect electrical or mechanical performance.
-
Availability: The RP10-1215DA/XC-HC has confirmed inventory availability (899 Pcs), ensuring supply continuity.
Frequently Asked Questions (FAQ)
Q: Can the RP10-1215DA/XC-HC be used as a direct replacement for the RP10-1215DA-HC in existing designs?
A: Yes. The RP10-1215DA/XC-HC is a direct substitute. All electrical parameters, mechanical dimensions, pin configuration, and protection features are identical. The substitute part can be installed without circuit modifications or PCB redesign.
Q: What is the difference between the RP10-1215DA-HC and RP10-1215DA/XC-HC?
A: The primary differences are product status and packaging format. The RP10-1215DA-HC is obsolete, while the RP10-1215DA/XC-HC is in active production. The substitute includes Remote On/Off functionality as an additional feature. Both parts are electrically and mechanically equivalent.
Q: Are the physical dimensions identical?
A: Yes. Both parts measure 25.4mm × 25.4mm × 16.5mm and use Through Hole mounting in a 6-DIP Module package. They are footprint-compatible and require no PCB modifications.
Q: Does the additional Remote On/Off feature in the substitute part affect compatibility?
A: No. The Remote On/Off feature is an enhancement that does not compromise compatibility. Existing designs that do not utilize this feature will operate identically to the original part. Designs requiring remote control capability can leverage this additional functionality.
Q: Are both parts RoHS compliant?
A: Yes. Both the RP10-1215DA-HC and RP10-1215DA/XC-HC are ROHS3 compliant and carry identical Moisture Sensitivity Level (MSL) ratings of 1 (Unlimited).
Q: What is the isolation voltage specification?
A: Both parts provide 1.6 kV isolation voltage, suitable for applications requiring galvanic isolation between input and output circuits.
Q: Can these parts be used interchangeably in production?
A: Yes. The RP10-1215DA/XC-HC is the recommended production part due to its active status and confirmed availability. It is fully interchangeable with the obsolete RP10-1215DA-HC.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts