Equivalent & Substitute Parts for RN143-6-02

Part Overview

RN143-6-02 is a two-line common mode choke manufactured by Schaffner EMC Inc. for power line filtering applications. It features a 1.8 mH inductance at 1 kHz, supports a maximum current of 6A, and is in a through-hole, horizontal package with 4 PC pins. This model is currently listed as obsolete, necessitating identification of electrically and mechanically equivalent alternatives to ensure availability and continued production compatibility.

Substiute Parts

RN143-6-02
Schaffner EMC Inc.In Stock: 1051RN143-6-02 Datasheet
RN143-6-02
Current Part
RN143-6-02-1M8
Schaffner EMC Inc.In Stock: 1119RN143-6-02-1M8 Datasheet
RN143-6-02-1M8
Direct
B82724A2602N020
EPCOS - TDK ElectronicsIn Stock: 1119B82724A2602N020 Datasheet
B82724A2602N020
Similar

Key Parameters

Manufacturer Part Number Inductance @ Frequency Current Rating (Max) DC Resistance (DCR) (Max) Voltage Rating - AC Operating Temperature Approval Agency Mounting Type Size / Dimension Height (Max) Package / Case Number of Lines RoHS Status
RN143-6-02 1.8 mH @ 1 kHz 6A (Typ) 20mOhm (Typ) 250V -40°C ~ 125°C UR, VDE Through Hole 1.303" L x 1.280" W (33.10mm x 32.50mm) 0.787" (20.00mm) Horizontal, 4 PC Pin 2 RoHS Compliant

Substitute Part Grouping Explanation

Substitute parts are identified strictly according to matching or compatible parameters: inductance value, current rating, DC resistance, voltage rating, operating temperature range, approval agency certifications, mounting type, package dimensions, line count, and RoHS compliance. Only components meeting these explicit criteria for electrical, mechanical, and certification parameters have been included as direct or similar substitutes.

Parameter Comparison

Manufacturer Part Number Manufacturer Inductance @ Frequency Current Rating (Max) DC Resistance (DCR) (Max) Voltage Rating - AC Operating Temperature Approval Agency Mounting Type Size / Dimension Height (Max) Package / Case Number of Lines RoHS Status Part Status
RN143-6-02 Schaffner EMC Inc. 1.8 mH @ 1 kHz 6A (Typ) 20mOhm (Typ) 250V -40°C ~ 125°C UR, VDE Through Hole 1.303" L x 1.280" W 0.787" (20.00mm) Horizontal, 4 PC Pin 2 RoHS Compliant Obsolete
RN143-6-02-1M8 Schaffner EMC Inc. 1.8 mH @ 10 kHz 6A 20mOhm (Typ) 300V -40°C ~ 100°C ENEC, UR, VDE Through Hole 1.303" L x 1.280" W 0.787" (20.00mm) Horizontal, 4 PC Pin 2 ROHS3 Compliant Active
B82724A2602N020 EPCOS - TDK Electronics 1.8 mH @ 10 kHz 6A 31mOhm (Typ) 250V -40°C ~ 125°C ENEC, UR, VDE Through Hole 1.303" L x 1.280" W 0.776" (19.70mm) Horizontal, 4 PC Pin 2 ROHS3 Compliant Active

Engineering Selection Recommendations

Selection of substitute parts for RN143-6-02 should be based on product status (obsolete vs. active), RoHS compliance status, and matching approval agencies. Only parts with the same or greater compliance (ENEC, UR, VDE) and current active status are included. For environmental compliance, ensure the chosen model fulfills the stated RoHS requirements. Matching package dimensions, mounting type, and mechanical configuration is also necessary for direct board placement.

Frequently Asked Questions (FAQ)

Q: What is the primary criteria for substituting RN143-6-02?
A: Substitution is based strictly on matching inductance, current rating, package type, DC resistance, operating temperature range, approval agency certifications, mechanical dimensions, and RoHS status.

Q: Are the substitute parts footprint-compatible with RN143-6-02?
A: All listed substitutes share the same mounting type (through hole, horizontal, 4 PC pin) and near-identical dimensions, supporting direct compatibility.

Q: Is there any difference in approval agency certification among substitutes?
A: The substitutes meet equivalent or broader agency certifications (ENEC, UR, VDE).

Q: Can substitutes be used in the same environmental conditions?
A: Substitute selections maintain comparable or overlapping operating temperature ranges and RoHS/REACH statuses.

Q: How does package dimension impact substitution?
A: Package dimension must match for mechanical drop-in replacement in existing PCB layouts; all substitutes meet this criterion.

Q: Does the frequency at which inductance is specified affect compatibility?
A: Substitute inductance values are specified at 10 kHz rather than 1 kHz, but the nominal inductance value remains identical.

Q: What considerations are given for part status?
A: Only active substitutes are selected to ensure ongoing availability and support for production requirements.

Request Quote (Ships tomorrow)