Equivalent & Substitute Parts Reference for RN122-2-02

Part Overview

Schaffner EMC Inc. RN122-2-02 is a 6.8 mH @ 10 kHz, 2A, 2-line power line common mode choke with through-hole mounting. The part is categorized as obsolete, which necessitates the selection of substitute models for current designs, spare parts, or maintenance. Substitutes must match key electrical, mechanical, and regulatory parameters to ensure equivalent performance and compatibility.

Substiute Parts

RN122-2-02
Schaffner EMC Inc.In Stock: 1111RN122-2-02 Datasheet
RN122-2-02
Current Part
RN122-2-02-6M8
Schaffner EMC Inc.In Stock: 855RN122-2-02-6M8 Datasheet
RN122-2-02-6M8
Direct
B82724J2202N001
EPCOS - TDK ElectronicsIn Stock: 2158B82724J2202N001 Datasheet
B82724J2202N001
Similar

Key Parameters

ParameterValue
Inductance @ Frequency6.8 mH @ 10 kHz
Current Rating (Max)2A (Typ)
DC Resistance (DCR) (Max)160mOhm (Typ)
Voltage Rating - AC250V
Operating Temperature-40°C ~ 125°C
Approval AgencyUR, VDE
Number of Lines2
Mounting TypeThrough Hole
Size / Dimension1.102" L x 1.063" W (28.00mm x 27.00mm)
Height (Max)0.661" (16.80mm)
Package / CaseHorizontal, 4 PC Pin
RoHS StatusRoHS Compliant
REACH StatusREACH Unaffected

Substitute Part Grouping Explanation

Substitute parts for RN122-2-02 are selected strictly based on the following allowed parameters from the product category: inductance at frequency, current rating, DCR, AC voltage rating, operating temperature range, number of lines, mounting type, mechanical dimensions, approval/certification status, and compliance with RoHS and REACH. All listed substitutes match these parameters within their specified values and are suitable for power line common mode choke applications with through-hole mounting and 2-line operation.

Parameter Comparison

Parameter Main Part: RN122-2-02 Substitute: RN122-2-02-6M8 Substitute: B82724J2202N001
Inductance @ Frequency 6.8 mH @ 10 kHz 6.8 mH @ 10 kHz 6.8 mH @ 10 kHz
Current Rating (Max) 2A (Typ) 2A 2A
DC Resistance (DCR) (Max) 160mOhm (Typ) 156mOhm (Typ) 170mOhm (Typ)
Voltage Rating - AC 250V 300V 250V
Operating Temperature -40°C ~ 125°C -40°C ~ 100°C -40°C ~ 125°C
Approval Agency UR, VDE ENEC, UR, VDE ENEC, UR, VDE
Number of Lines 2 2 2
Mounting Type Through Hole Through Hole Through Hole
Size / Dimension 1.102" L x 1.063" W (28.00mm x 27.00mm) 0.886" L x 0.846" W (22.50mm x 21.50mm) 1.232" L x 0.728" W (31.30mm x 18.50mm)
Height (Max) 0.661" (16.80mm) 0.531" (13.50mm) 1.307" (33.20mm)
Package / Case Horizontal, 4 PC Pin Horizontal, 4 PC Pin Vertical, 4 PC Pin
RoHS Status RoHS Compliant ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected REACH Affected

Engineering Selection Recommendations

RN122-2-02 is obsolete and requires substitution to maintain compliance with design, certification, and inventory requirements. RN122-2-02-6M8 and B82724J2202N001 are both active, RoHS3 compliant, and hold ENEC, UR, and VDE approvals. RN122-2-02-6M8 offers the closest electrical and mechanical specifications, with slight differences in mechanical size and DCR. B82724J2202N001 also meets the electrical criteria, with variations in package orientation, dimension, and REACH status. Selection should be based on the required compliance and matching certification to the original part.

Frequently Asked Questions (FAQ)

Q1: Which key parameters must be matched when substituting common mode chokes in power line applications?
A1: Inductance at specified frequency, current rating, DCR, AC voltage rating, number of lines, operating temperature range, approval/certification, mounting type, and mechanical dimensions.

Q2: Is package orientation significant when selecting substitutes?
A2: Yes, package orientation and pin configuration (horizontal or vertical, 4 PC Pin) must align with the original footprint and PCB design requirements.

Q3: How does regulatory compliance affect substitution?
A3: Substitute parts must be RoHS and REACH compliant where specified and carry approvals such as UR, VDE, or ENEC if required by the application or region.

Q4: What if the substitute part's mechanical dimensions differ from the original?
A4: Any dimensional differences must be verified against the application requirements for fit and clearance in the assembly.

Q5: Are certificate approvals necessary when using substitute inductive components?
A5: Yes, equivalent certification (UR, VDE, ENEC) ensures continued regulatory and safety compliance for the replacement part.

Request Quote (Ships tomorrow)