Request Quote
(Ships tomorrow)
RLY70000 Equivalent & Substitute Parts Reference
Part Overview
The RLY70000 is a Solid State 3PST-NO (3 Form A) relay manufactured by Red Lion Controls, designed for DIN Rail mounting with integrated heat sink. This component operates with 4–32VDC input control and handles AC loads up to 25A with zero-cross switching capability. The RLY70000 is classified as obsolete, necessitating identification of active equivalent models to maintain system continuity and ensure long-term component availability for new designs and field replacements.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | RLY70000 |
| Manufacturer | Red Lion Controls |
| Series | RLY7 |
| Circuit Configuration | 3PST-NO (3 Form A) |
| Output Type | AC, Zero Cross |
| Voltage - Input | 4 ~ 32VDC |
| Voltage - Load | 24 V ~ 660 V |
| Load Current | 25 A |
| Mounting Type | DIN Rail |
| Termination Style | Screw Terminal |
| Package / Case | SSR with Integrated Heat Sink |
| Product Status | Obsolete |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution of the RLY70000 is determined by strict equivalence across the following critical parameters:
Mandatory Matching Parameters:
- Circuit configuration: 3PST-NO (3 Form A)
- Output type: AC, Zero Cross
- Input voltage range: 4 ~ 32VDC
- Load current rating: 25 A
- Mounting type: DIN Rail
- Termination style: Screw Terminal
- Package type: SSR with Integrated Heat Sink
- Series family: RLY7
Allowable Variation:
- Load voltage range may differ provided the substitute operates within the application's specified load voltage requirements
The RLY70100 is identified as the manufacturer-recommended substitute. This part maintains identical input control voltage, circuit topology, current rating, mounting configuration, and termination method. The load voltage range differs (48 V ~ 600 V versus 24 V ~ 660 V), which represents a narrower upper limit but remains suitable for applications operating within the 48–600V window.
Parameter Comparison
| Parameter | RLY70000 (Obsolete) | RLY70100 (Active Substitute) |
|---|---|---|
| Manufacturer Part Number | RLY70000 | RLY70100 |
| Manufacturer | Red Lion Controls | Red Lion Controls |
| Series | RLY7 | RLY7 |
| Circuit Configuration | 3PST-NO (3 Form A) | 3PST-NO (3 Form A) |
| Output Type | AC, Zero Cross | AC, Zero Cross |
| Voltage - Input | 4 ~ 32VDC | 4 ~ 32VDC |
| Voltage - Load | 24 V ~ 660 V | 48 V ~ 600 V |
| Load Current | 25 A | 25 A |
| Mounting Type | DIN Rail | DIN Rail |
| Termination Style | Screw Terminal | Screw Terminal |
| Package / Case | SSR with Integrated Heat Sink | SSR with Integrated Heat Sink |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| Product Status | Obsolete | Active |
Engineering Selection Recommendations
The RLY70100 is the designated manufacturer-recommended substitute for the obsolete RLY70000. Both components share identical electrical specifications for input control voltage (4–32VDC), circuit topology (3PST-NO), output switching characteristics (AC, Zero Cross), and load current capacity (25A). Physical mounting and termination are equivalent, ensuring direct mechanical compatibility in DIN Rail installations.
The RLY70100 carries Active product status, ensuring ongoing manufacturer support, availability, and compliance with current regulatory standards. The RLY70100 is RoHS3 Compliant and REACH Unaffected, providing assurance for applications subject to environmental and hazardous substance restrictions.
The load voltage specification difference (48–600V for RLY70100 versus 24–660V for RLY70000) requires verification against the application's actual load voltage requirements. Applications operating loads within the 48–600V range experience full compatibility. Applications requiring operation below 48V or above 600V must be evaluated against alternative component options.
Frequently Asked Questions (FAQ)
Q: Can RLY70100 directly replace RLY70000 in existing installations?
A: Direct mechanical and electrical replacement is possible provided the application load voltage operates within the 48–600V range. Verify load voltage specifications before substitution. Screw terminal connections and DIN Rail mounting are identical between both models.
Q: What is the primary difference between RLY70000 and RLY70100?
A: The load voltage operating range differs. RLY70000 operates 24–660V; RLY70100 operates 48–600V. All other electrical and mechanical parameters are identical. The RLY70100 is the active production model.
Q: Is RLY70100 compliant with environmental regulations?
A: RLY70100 is RoHS3 Compliant and REACH Unaffected, meeting current environmental and hazardous substance directives applicable to electronic components.
Q: What is the input control voltage for both models?
A: Both RLY70000 and RLY70100 accept 4–32VDC input control voltage with identical switching characteristics.
Q: Are the physical packages identical?
A: Both models feature SSR with Integrated Heat Sink packaging, DIN Rail mounting, and Screw Terminal termination. Physical form factor and installation method are equivalent.
Q: What circuit configuration do these relays provide?
A: Both models provide 3PST-NO (3 Form A) configuration, delivering three independent normally-open switching channels with AC zero-cross output switching.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts