RF292A4PCCDP Equivalent & Substitute Parts

Part Overview

The RF292A4PCCDP is a 2.92mm coaxial connector plug manufactured by Bulgin, designed for panel mount applications with through-hole solder termination. This connector operates at frequencies up to 40 GHz with 50 Ohm impedance and is rated for 250 V operation across a temperature range of -40°C to 85°C. The part is currently active in production status with 834 units in stock. Substitute parts are identified when design requirements permit variation in specific mounting configurations or packaging options while maintaining core electrical and mechanical compatibility.

Substiute Parts

RF292A4PCCDP
BulginIn Stock: 880RF292A4PCCDP Datasheet
RF292A4PCCDP
Current Part
RF292A2PEGDK
BulginIn Stock: 1171RF292A2PEGDK Datasheet
RF292A2PEGDK
Parametric Equivalent
RF292A4PCCA
BulginIn Stock: 1050RF292A4PCCA Datasheet
RF292A4PCCA
Parametric Equivalent
RF292A4PCCDK
BulginIn Stock: 981RF292A4PCCDK Datasheet
RF292A4PCCDK
Parametric Equivalent

Key Parameters

Parameter Value
Connector Style 2.92mm
Connector Type Plug, Male Pin
Impedance 50 Ohms
Frequency - Max 40 GHz
Mounting Type Panel Mount, Through Hole
Mounting Feature Flange
Contact Termination Solder
Shield Termination Solder
Operating Temperature -40°C ~ 85°C
Voltage Rating 250 V
Mating Cycles 500
Center Contact Material Beryllium Copper
Body Material Stainless Steel
Dielectric Material Polyetherimide (PEI)
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution eligibility for the RF292A4PCCDP is determined by strict equivalence across the following critical parameters:

Electrical Equivalence Requirements:

  • Connector style: 2.92mm
  • Connector type: Plug, Male Pin
  • Impedance: 50 Ohms
  • Frequency rating: 40 GHz maximum
  • Voltage rating: 250 V
  • Operating temperature range: -40°C to 85°C

Mechanical Equivalence Requirements:

  • Mounting type: Panel Mount, Through Hole
  • Mounting feature: Flange
  • Contact termination: Solder
  • Shield termination: Solder
  • Center contact material: Beryllium Copper
  • Body material: Stainless Steel
  • Dielectric material: Polyetherimide (PEI)

Compliance Requirements:

  • RoHS3 Compliant
  • Moisture Sensitivity Level: 1 (Unlimited)
  • ECCN: EAR99
  • HTSUS: 8536.69.4010

Substitute parts may differ in the number of mounting holes (flange hole count) provided all other parameters remain identical. This variation does not affect electrical performance or core mechanical function, only the physical mounting configuration on the panel.

Parameter Comparison

Parameter RF292A4PCCDP RF292A4PCCA RF292A4PCCDK RF292A2PEGDK
Connector Style 2.92mm 2.92mm 2.92mm 2.92mm
Connector Type Plug, Male Pin Plug, Male Pin Plug, Male Pin Plug, Male Pin
Contact Termination Solder Solder Solder Solder
Shield Termination Solder Solder Solder Solder
Impedance 50 Ohms 50 Ohms 50 Ohms 50 Ohms
Mounting Type Panel Mount, Through Hole Panel Mount, Through Hole Panel Mount, Through Hole Panel Mount, Through Hole
Mounting Feature Flange Flange Flange Flange
Fastening Type Threaded Threaded Threaded Threaded
Frequency - Max 40 GHz 40 GHz 40 GHz 40 GHz
Number of Ports 1 1 1 1
Housing Color Silver Silver Silver Silver
Center Contact Material Beryllium Copper Beryllium Copper Beryllium Copper Beryllium Copper
Body Material Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Dielectric Material Polyetherimide (PEI) Polyetherimide (PEI) Polyetherimide (PEI) Polyetherimide (PEI)
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C -40°C ~ 85°C -40°C ~ 85°C
Voltage Rating 250 V 250 V 250 V 250 V
Mating Cycles 500 500 500 500
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)
ECCN EAR99 EAR99 EAR99 EAR99
HTSUS 8536.69.4010 8536.69.4010 8536.69.4010 8536.69.4010
Mounting Hole Count 4 Hole 4 Hole 4 Hole 2 Hole
Product Status Active Active Active Active
Inventory (Pcs) 834 972 922 1128

Engineering Selection Recommendations

All substitute parts listed are active production items manufactured by Bulgin and maintain full ROHS3 compliance with identical electrical and mechanical specifications to the RF292A4PCCDP. Selection between the four-hole variants (RF292A4PCCDP, RF292A4PCCA, RF292A4PCCDK) is determined by panel mounting hole availability and design layout requirements. The two-hole variant (RF292A2PEGDK) is selected when panel design specifies two-hole flange mounting.

RF292A4PCCA and RF292A4PCCDK are direct functional equivalents to RF292A4PCCDP with identical four-hole flange configurations. RF292A2PEGDK provides equivalent electrical and mechanical performance with a two-hole flange mounting feature.

All parts share identical compliance certifications, operating parameters, and material specifications. Selection is based on panel mounting hole pattern requirements and inventory availability.

Frequently Asked Questions (FAQ)

Q: Can RF292A2PEGDK be used as a direct replacement for RF292A4PCCDP?

A: RF292A2PEGDK is electrically and mechanically equivalent to RF292A4PCCDP. The difference is the flange mounting hole count: two holes versus four holes. Substitution is valid only if the panel design accommodates two-hole mounting. All electrical parameters, impedance, frequency rating, and operating conditions are identical.

Q: What is the difference between RF292A4PCCA and RF292A4PCCDK?

A: Both parts are four-hole flange variants with identical electrical and mechanical specifications. They differ only in manufacturing or packaging designation. Both are fully equivalent to RF292A4PCCDP and interchangeable in applications requiring four-hole panel mounting.

Q: Are all substitute parts RoHS3 compliant?

A: Yes. RF292A4PCCA, RF292A4PCCDK, and RF292A2PEGDK are all ROHS3 compliant with identical compliance status to the RF292A4PCCDP.

Q: Does the mounting hole count affect electrical performance?

A: No. The mounting hole count (two versus four) is a mechanical design feature only. All electrical parameters including impedance, frequency response, and signal integrity remain identical across all variants.

Q: What is the operating temperature range for all substitute parts?

A: All substitute parts operate across the identical temperature range of -40°C to 85°C with 250 V voltage rating and 500 mating cycles.

Q: Can these connectors be used interchangeably in high-frequency applications?

A: Yes. All parts are rated to 40 GHz maximum frequency with 50 Ohm impedance. Substitution is valid for applications within this frequency specification regardless of which variant is selected, provided the panel mounting hole pattern is compatible.

Request Quote (Ships tomorrow)