Equivalent & Substitute Parts for REM6-4815DW/C

Part Overview

REM6-4815DW/C from Recom Power is an active DC-DC converter module, designed to provide isolated dual output voltages of +15V and -15V at up to 200mA each, with a power rating of 6W. It is utilized in both ITE (Commercial) and Medical applications. Identifying equivalent and substitute DC-DC converter modules is necessary to maintain supply chain flexibility, enable cross-referencing within designs, and ensure uninterrupted manufacturing when stock levels or compliance statuses demand substitution.

Substiute Parts

REM6-4815DW/C
Recom PowerIn Stock: 950REM6-4815DW/C Datasheet
REM6-4815DW/C
Current Part
URA4815YMD-6WR3
Mornsun America, LLCIn Stock: 820URA4815YMD-6WR3 Datasheet
URA4815YMD-6WR3
Similar

Key Parameters

Manufacturer Part Number Manufacturer Series Product Status Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Voltage - Output 2 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS Inventory
REM6-4815DW/C Recom Power MEDLINE REM6 (6W) Active Isolated Module 2 18V 75V 15V -15V 200mA, 200mA 6 W 5 kV ITE (Commercial), Medical Remote On/Off, OCP, OVP, SCP, UVLO -40°C ~ 105°C 87% Through Hole 24-DIP Module, 6 Leads 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9580 877 Pcs
URA4815YMD-6WR3 Mornsun America, LLC URA_YMD-6WR3 (6W) Active Isolated Module 2 18V 75V 15V -15V 200mA, 200mA 6 W 1.5 kV ITE (Commercial) - -40°C ~ 85°C (With Derating) 88% Through Hole 5-DIP Module 1.00" L x 1.00" W x 0.46" H (25.4mm x 25.4mm x 11.7mm) RoHS Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9580 741 Pcs

Substitute Part Grouping Explanation

Substitute parts for DC-DC converter modules are determined by matching essential electrical and mechanical characteristics. The substitution logic strictly uses the following key parameters: input voltage range, output voltages, output current, power rating, type, number of outputs, mounting type, package/case, RoHS compliance, and product status. Additional considerations such as voltage isolation, efficiency, and operating temperature are referenced where directly provided.

Parameter Comparison

Parameter REM6-4815DW/C URA4815YMD-6WR3
Manufacturer Part Number REM6-4815DW/C URA4815YMD-6WR3
Manufacturer Recom Power Mornsun America, LLC
Product Status Active Active
Type Isolated Module Isolated Module
Number of Outputs 2 2
Voltage - Input (Min) 18V 18V
Voltage - Input (Max) 75V 75V
Voltage - Output 1 15V 15V
Voltage - Output 2 -15V -15V
Current - Output (Max) 200mA, 200mA 200mA, 200mA
Power (Watts) 6 W 6 W
Voltage - Isolation 5 kV 1.5 kV
Applications ITE (Commercial), Medical ITE (Commercial)
Operating Temperature -40°C ~ 105°C -40°C ~ 85°C (With Derating)
Efficiency 87% 88%
Mounting Type Through Hole Through Hole
Package / Case 24-DIP Module, 6 Leads 5-DIP Module
Size / Dimension 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) 1.00" L x 1.00" W x 0.46" H (25.4mm x 25.4mm x 11.7mm)
RoHS Status ROHS3 Compliant RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580
Inventory 877 Pcs 741 Pcs

Engineering Selection Recommendations

Both REM6-4815DW/C and URA4815YMD-6WR3 have active product status and comply with RoHS and REACH requirements. For applications where certifications such as CB, CE, and cURus are specified, the URA4815YMD-6WR3 includes these agency approvals as indicated in the provided parameters. Inventory levels for both parts are actively maintained, supporting direct cross-reference and substitution within the allowed range of parameters.

Frequently Asked Questions (FAQ)

Q1: What parameters define a suitable substitute for REM6-4815DW/C?
A1: Allowed substitutes must have matching input voltage range, output voltages, output current ratings, power rating, type, number of outputs, mounting method, package or case, RoHS compliance, and active product status.

Q2: Can URA4815YMD-6WR3 be used in place of REM6-4815DW/C?
A2: URA4815YMD-6WR3 matches the required electrical parameters, mounting type, and required compliance criteria as per the provided data.

Q3: Are there any dimensional or package differences that need consideration?
A3: REM6-4815DW/C is specified as a 24-DIP Module (6 Leads), while the substitute URA4815YMD-6WR3 is a 5-DIP Module, with different dimensions; review the package structure for mechanical fit.

Q4: How do compliance statuses affect substitution?
A4: Both parts are listed as RoHS compliant, REACH unaffected, and have the same ECCN and HTSUS codes, supporting their use in regulated environments.

Q5: What about isolation voltage and temperature requirements?
A5: The main part has a specified isolation voltage of 5 kV, and an operating temperature up to 105°C. The substitute provides 1.5 kV isolation and operates up to 85°C (with derating), as stated in the input data.

Request Quote (Ships tomorrow)