Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts Reference: REM6-4805SW/C
Part Overview
The REM6-4805SW/C from Recom Power is an isolated DC-DC converter module, offering a single 5V output at up to 1.2A from a wide input range (18V to 75V). It is suitable for both ITE (Commercial) and Medical applications and features 6W output power, 5kV isolation, and a compact through-hole 24-DIP module package. The product is in active status, with RoHS and REACH compliance, and a moisture sensitivity level of 1 (unlimited). Due to supply chain requirements, design flexibility, or compliance concerns, identifying alternative models with similar electrical and mechanical characteristics is necessary to ensure uninterrupted device production and maintenance.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Description | Type | Series | Product Status | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| REM6-4805SW/C | Recom Power | DC DC CONVERTER 5V 6W | Isolated Module | MEDLINE REM6 (6W) | Active | 1 | 18V | 75V | 5V | 1.2A | 6W | 5kV | ITE (Commercial), Medical | -40°C ~ 105°C | 86.5% | Through Hole | 24-DIP Module, 5 Leads | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitution logic is based exclusively on the following technical parameters: product status, number of outputs, input voltage range, output voltage and current, output power, isolation voltage, mount type and package, size/dimensions, operating temperature, RoHS and REACH status, and moisture sensitivity level. Only parts meeting or closely matching these defined values are included as substitutes.
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Description | Type | Series | Product Status | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| REM6-4805SW/C | Recom Power | DC DC CONVERTER 5V 6W | Isolated Module | MEDLINE REM6 (6W) | Active | 1 | 18V | 75V | 5V | 1.2A | 6W | 5kV | ITE (Commercial), Medical | -40°C ~ 105°C | 86.5% | Through Hole | 24-DIP Module, 5 Leads | 1.25" L x 0.80" W x 0.40" H (31.8mm x 20.3mm x 10.2mm) | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 |
| URB4805YMD-6WR3 | Mornsun America, LLC | DC DC CONVERTER 5V 6W | Isolated Module | URB_YMD-6WR3 (6W) | Active | 1 | 18V | 75V | 5V | 1.2A | 6W | 1.5kV | ITE (Commercial), Railway | -40°C ~ 85°C (With Derating) | 83% | Through Hole | 5-DIP Module, 4 Leads | 1.00" L x 1.00" W x 0.46" H (25.4mm x 25.4mm x 11.7mm) | RoHS Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 |
Engineering Selection Recommendations
Both REM6-4805SW/C and URB4805YMD-6WR3 are active products with RoHS and REACH compliance and an unlimited moisture sensitivity level. For substitutions within the "Isolated Module DC-DC Converter" category, product status should be active and regulatory compliance should match project or application requirements. Both part numbers conform to these conditions.
Frequently Asked Questions (FAQ)
Q1: Which electrical parameters are mandatory for substitution of isolated DC-DC converter modules?
A1: Allowed substitutions must exactly match the number of outputs, input voltage range, output voltage, output current, and power rating.
Q2: How does isolation voltage affect part substitution?
A2: Isolation voltage is a critical parameter for safety and application-specific requirements; select alternate parts with equal or greater isolation voltage as specified.
Q3: Do package type and mechanical dimension differences impact compatibility?
A3: Package type, lead count, and physical dimensions must match the application board layout. Compare package specifications before selection.
Q4: Is regulatory compliance required for substitution?
A4: RoHS, REACH, and MSL compliance must be equivalent to ensure environmental and operational compatibility.
Q5: Is efficiency or operating temperature a substitution criterion?
A5: Efficiency and operating temperature must be reviewed to confirm suitability for the intended operating environment, as specified by provided data.
Q6: Can substitute components have different application approvals or certifications?
A6: Approval agency listings (e.g., Medical, Railway) should be reviewed in accordance with the target end-use; only supplied certification parameters are considered for substitution.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts