REC15-483.4S/H3 Equivalent & Substitute Parts Reference

Part Overview

The REC15-483.4S/H3 from Recom Power is an isolated DC-DC converter designed for ITE (Commercial) applications. It delivers 3.4V output at up to 3A with a power rating of 15W, accepting input voltages from 36V to 75V. The part features remote on/off, OCP (overcurrent protection), and SCP (short-circuit protection), with efficiency rated at 85%. The REC15-483.4S/H3 is classified as obsolete, necessitating the identification of alternative models meeting identical electrical, mechanical, and regulatory specifications to maintain design compatibility and supply continuity.

Substiute Parts

REC15-483.4S/H3
Recom PowerIn Stock: 896REC15-483.4S/H3 Datasheet
REC15-483.4S/H3
Current Part
REC15-483.4S/H3/M
Recom PowerIn Stock: 1017REC15-483.4S/H3/M Datasheet
REC15-483.4S/H3/M
Direct

Key Parameters

Parameter Value
Manufacturer Part Number REC15-483.4S/H3
Series ECONOLINE REC15 (15W)
Product Status Obsolete
Type Isolated Module
Number of Outputs 1
Voltage - Input (Min) 36V
Voltage - Input (Max) 75V
Voltage - Output 1 3.4V
Current - Output (Max) 3A
Power (Watts) 15 W
Voltage - Isolation 3 kV
Applications ITE (Commercial)
Features Remote On/Off, OCP, SCP
Operating Temperature -40°C ~ 71°C
Efficiency 85%
Mounting Type Through Hole
Package / Case 6-DIP Module
Size / Dimension 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm)
Control Features Enable, Active High
RoHS Status ROHS3 Compliant
MSL 1 (Unlimited)
REACH Status REACH Unaffected
ECCN EAR99
HTSUS 8504.40.9580

Substitute Part Grouping Explanation

Substitute selection is conducted strictly on the basis of matching key technical parameters, regulatory compliance, and mechanical compatibility. The critical matching criteria include: DC-DC converter isolated module type, single output, identical input voltage range (36V – 75V), output voltage (3.4V), output current (3A), power rating (15W), voltage isolation (3 kV), package dimensions, mounting type (through hole, 6-DIP module), control features, and operating temperature range. RoHS and REACH compliance, as well as inventory status, are also included as strict selection parameters.

Parameter Comparison

Parameter Main Part: REC15-483.4S/H3 Substitute: REC15-483.4S/H3/M
Manufacturer Recom Power Recom Power
Description DC DC CONVERTER 3.4V 15W DC DC CONVERTER 3.4V 15W
Series ECONOLINE REC15 (15W) ECONOLINE REC15/M (15W)
Product Status Obsolete Active
Type Isolated Module Isolated Module
Number of Outputs 1 1
Voltage - Input (Min) 36V 36V
Voltage - Input (Max) 75V 75V
Voltage - Output 1 3.4V 3.4V
Current - Output (Max) 3A 3A
Power (Watts) 15 W 15 W
Voltage - Isolation 3 kV 3 kV
Applications ITE (Commercial) ITE (Commercial), Medical
Features Remote On/Off, OCP, SCP Remote On/Off, OCP, SCP, UVLO
Operating Temperature -40°C ~ 71°C -40°C ~ 71°C
Efficiency 85% 86%
Mounting Type Through Hole Through Hole
Package / Case 6-DIP Module 6-DIP Module
Size / Dimension 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm)
Control Features Enable, Active High Enable, Active High
RoHS Status ROHS3 Compliant ROHS3 Compliant
MSL 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

The main part, REC15-483.4S/H3, has been designated as obsolete. The substitute part, REC15-483.4S/H3/M, is currently active and maintains identical electrical, mechanical, and package parameters, while also being ROHS3 compliant and REACH unaffected. For continuity in production and inventory purposes, a transition to REC15-483.4S/H3/M provides compliance with all defined certifications and environmental standards as specified in the provided parameter list.

Frequently Asked Questions (FAQ)

Q1: Which key parameters must match when substituting an isolated DC-DC converter?
A1: Key parameters include type (isolated module), input voltage range (36V – 75V), output voltage (3.4V), maximum output current (3A), power rating (15W), isolation voltage (3 kV), mounting type (through hole), package (6-DIP module), operating temperature range, features, and regulatory compliance.

Q2: Can the REC15-483.4S/H3/M be installed in the same footprint as the REC15-483.4S/H3?
A2: Both models share identical mechanical dimensions and package type (6-DIP module), supporting physical interchangeability.

Q3: Are there any changes in environmental or compliance status between these parts?
A3: Both REC15-483.4S/H3 and REC15-483.4S/H3/M are ROHS3 compliant, REACH unaffected, with identical environmental and compliance parameters as provided.

Q4: Does the substitute part offer additional features?
A4: The substitute REC15-483.4S/H3/M includes all features of the main part and lists UVLO (under-voltage lockout) as an additional feature in the parameter set.

Q5: What documentation should be reviewed when switching to the substitute part?
A5: Review the matching key parameters related to electrical, mechanical, and regulatory specifications as provided to ensure suitability within the application.

Request Quote (Ships tomorrow)