Part Overview
The REC15-483.4S/H3 from Recom Power is an isolated DC-DC converter designed for ITE (Commercial) applications. It delivers 3.4V output at up to 3A with a power rating of 15W, accepting input voltages from 36V to 75V. The part features remote on/off, OCP (overcurrent protection), and SCP (short-circuit protection), with efficiency rated at 85%. The REC15-483.4S/H3 is classified as obsolete, necessitating the identification of alternative models meeting identical electrical, mechanical, and regulatory specifications to maintain design compatibility and supply continuity.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | REC15-483.4S/H3 |
| Series | ECONOLINE REC15 (15W) |
| Product Status | Obsolete |
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 36V |
| Voltage - Input (Max) | 75V |
| Voltage - Output 1 | 3.4V |
| Current - Output (Max) | 3A |
| Power (Watts) | 15 W |
| Voltage - Isolation | 3 kV |
| Applications | ITE (Commercial) |
| Features | Remote On/Off, OCP, SCP |
| Operating Temperature | -40°C ~ 71°C |
| Efficiency | 85% |
| Mounting Type | Through Hole |
| Package / Case | 6-DIP Module |
| Size / Dimension | 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) |
| Control Features | Enable, Active High |
| RoHS Status | ROHS3 Compliant |
| MSL | 1 (Unlimited) |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute selection is conducted strictly on the basis of matching key technical parameters, regulatory compliance, and mechanical compatibility. The critical matching criteria include: DC-DC converter isolated module type, single output, identical input voltage range (36V – 75V), output voltage (3.4V), output current (3A), power rating (15W), voltage isolation (3 kV), package dimensions, mounting type (through hole, 6-DIP module), control features, and operating temperature range. RoHS and REACH compliance, as well as inventory status, are also included as strict selection parameters.
Parameter Comparison
| Parameter | Main Part: REC15-483.4S/H3 | Substitute: REC15-483.4S/H3/M |
|---|---|---|
| Manufacturer | Recom Power | Recom Power |
| Description | DC DC CONVERTER 3.4V 15W | DC DC CONVERTER 3.4V 15W |
| Series | ECONOLINE REC15 (15W) | ECONOLINE REC15/M (15W) |
| Product Status | Obsolete | Active |
| Type | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 36V | 36V |
| Voltage - Input (Max) | 75V | 75V |
| Voltage - Output 1 | 3.4V | 3.4V |
| Current - Output (Max) | 3A | 3A |
| Power (Watts) | 15 W | 15 W |
| Voltage - Isolation | 3 kV | 3 kV |
| Applications | ITE (Commercial) | ITE (Commercial), Medical |
| Features | Remote On/Off, OCP, SCP | Remote On/Off, OCP, SCP, UVLO |
| Operating Temperature | -40°C ~ 71°C | -40°C ~ 71°C |
| Efficiency | 85% | 86% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | 6-DIP Module | 6-DIP Module |
| Size / Dimension | 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) | 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) |
| Control Features | Enable, Active High | Enable, Active High |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| MSL | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
The main part, REC15-483.4S/H3, has been designated as obsolete. The substitute part, REC15-483.4S/H3/M, is currently active and maintains identical electrical, mechanical, and package parameters, while also being ROHS3 compliant and REACH unaffected. For continuity in production and inventory purposes, a transition to REC15-483.4S/H3/M provides compliance with all defined certifications and environmental standards as specified in the provided parameter list.
Frequently Asked Questions (FAQ)
Q1: Which key parameters must match when substituting an isolated DC-DC converter?
A1: Key parameters include type (isolated module), input voltage range (36V – 75V), output voltage (3.4V), maximum output current (3A), power rating (15W), isolation voltage (3 kV), mounting type (through hole), package (6-DIP module), operating temperature range, features, and regulatory compliance.
Q2: Can the REC15-483.4S/H3/M be installed in the same footprint as the REC15-483.4S/H3?
A2: Both models share identical mechanical dimensions and package type (6-DIP module), supporting physical interchangeability.
Q3: Are there any changes in environmental or compliance status between these parts?
A3: Both REC15-483.4S/H3 and REC15-483.4S/H3/M are ROHS3 compliant, REACH unaffected, with identical environmental and compliance parameters as provided.
Q4: Does the substitute part offer additional features?
A4: The substitute REC15-483.4S/H3/M includes all features of the main part and lists UVLO (under-voltage lockout) as an additional feature in the parameter set.
Q5: What documentation should be reviewed when switching to the substitute part?
A5: Review the matching key parameters related to electrical, mechanical, and regulatory specifications as provided to ensure suitability within the application.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts