Equivalent & Substitute Parts Reference for REC15-483.4S/H2

Part Overview

The REC15-483.4S/H2 from Recom Power is an isolated DC-DC converter module featuring 15W output power at 3.4V/3A, designed for ITE (Commercial) applications. It supports a wide input voltage range (36V to 75V), remote on/off, OCP, and SCP features, with 2 kV isolation. The module is delivered in a 6-DIP through-hole package and is compliant with ROHS3 and REACH regulations. The REC15-483.4S/H2 is classified as obsolete, which requires evaluation and selection of alternative models that meet identical electrical, mechanical, and regulatory parameters for sustained design support and inventory availability.

Substiute Parts

REC15-483.4S/H2
Recom PowerIn Stock: 12302REC15-483.4S/H2 Datasheet
REC15-483.4S/H2
Current Part
REC15-483.4S/H2/M
Recom PowerIn Stock: 908REC15-483.4S/H2/M Datasheet
REC15-483.4S/H2/M
Direct

Key Parameters

Manufacturer Part Number Input Voltage Range Output Voltage Output Current (Max) Power (Watts) Isolation Voltage Efficiency Operating Temperature Mounting Type Package / Case Size / Dimension Number of Outputs Features Product Status RoHS Status REACH Status ECCN HTSUS Moisture Sensitivity Level (MSL) Applications
REC15-483.4S/H2 36V - 75V 3.4V 3A 15W 2 kV 85% -40°C ~ 71°C Through Hole 6-DIP Module 2.00" x 1.00" x 0.40" 1 Remote On/Off, OCP, SCP Obsolete ROHS3 Compliant REACH Unaffected EAR99 8504.40.9580 1 (Unlimited) ITE (Commercial)

Substitute Part Grouping Explanation

Substitution is permitted only if all primary parameters align: input voltage range, output voltage and current ratings, isolation voltage, efficiency, operating temperature, mounting type, package/case size, regulatory compliance (RoHS/REACH), and application suitability. Substitute parts must match all listed values to ensure compatibility in form, fit, and function. The substitute REC15-483.4S/H2/M has been explicitly listed, sharing every specified key electrical, mechanical, and compliance attribute.

Parameter Comparison

Parameter REC15-483.4S/H2 REC15-483.4S/H2/M
Manufacturer Recom Power Recom Power
Input Voltage Range 36V - 75V 36V - 75V
Output Voltage 3.4V 3.4V
Output Current (Max) 3A 3A
Power (Watts) 15W 15W
Isolation Voltage 2 kV 2 kV
Efficiency 85% 85%
Operating Temperature -40°C ~ 71°C -40°C ~ 71°C
Mounting Type Through Hole Through Hole
Package / Case 6-DIP Module 6-DIP Module
Size / Dimension 2.00" x 1.00" x 0.40" 2.00" x 1.00" x 0.40"
Number of Outputs 1 1
Features Remote On/Off, OCP, SCP Remote On/Off, OCP, SCP, UVLO
Product Status Obsolete Active
RoHS Status ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
Applications ITE (Commercial) ITE (Commercial), Medical

Engineering Selection Recommendations

The REC15-483.4S/H2 is obsolete and ROHS3 compliant with REACH unaffected status. The substitute REC15-483.4S/H2/M is both ROHS3 compliant and REACH unaffected, and is listed as an active product. Both models share identical compliance, performance, and form factor specifications. The substitute part adheres to the moisture sensitivity and ECCN requirements stated for the main part, supporting direct replacement in all qualified applications. Use only the listed substitute per certified compliance and inventory status.

Frequently Asked Questions (FAQ)

Q1: What parameters must match for a valid REC15-483.4S/H2 substitute?
All electrical ratings (input voltage, output voltage, current, power, isolation voltage), mechanical features (mounting type, package/case, size/dimension), and regulatory compliance (RoHS, REACH, ECCN, MSL) must match exactly.

Q2: Is package compatibility ensured between REC15-483.4S/H2 and REC15-483.4S/H2/M?
Both parts are specified in the same 6-DIP module package with identical dimensions, ensuring mechanical compatibility.

Q3: Does the substitute part support the same operating conditions as the original?
The substitute maintains the same input range, output ratings, isolation, efficiency, and ambient temperature specification as the main part.

Q4: How does product status affect substitution?
The REC15-483.4S/H2 is obsolete; REC15-483.4S/H2/M is active. Selection of the substitute part is appropriate for continued production and inventory availability.

Q5: Are application categories identical for both parts?
Both are suitable for ITE (Commercial) applications; the substitute part also includes Medical application suitability per provided data.

Q6: Is compliance maintained with RoHS and REACH standards?
Both models are explicitly ROHS3 compliant and unaffected by REACH requirements.

Q7: Do control and protection features differ?
Both provide Remote On/Off, OCP, SCP; REC15-483.4S/H2/M additionally specifies UVLO per input. All base protection and control requirements are met.

Request Quote (Ships tomorrow)