The REC15-4815S/H2 from Recom Power is an isolated module DC-DC converter with one output, rated for 15V at 1A, and operates from a 36V to 75V input. As part of the ECONOLINE REC15 (15W) series, this device provides 2 kV isolation and through-hole mounting in a 6-DIP module case. Its features include remote on/off, overcurrent protection (OCP), and short circuit protection (SCP), with an operating temperature range of -40°C to 71°C and efficiency of 86%. The product status is listed as obsolete, which necessitates the identification and specification of alternative models with matching electrical, mechanical, and compliance parameters.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | Control Features | RoHS Status | MSL | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| REC15-4815S/H2 | ECONOLINE REC15 (15W) | Obsolete | Isolated Module | 1 | 36V | 75V | 15V | 1A | 15 W | 2 kV | ITE (Commercial) | Remote On/Off, OCP, SCP | -40°C ~ 71°C | 86% | Through Hole | 6-DIP Module | 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) | Enable, Active High | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 |
Substitute Part Grouping Explanation
Part substitution is determined strictly through direct comparison of key parameters: electrical ratings (input voltage range, output voltage, output current, power, isolation rating), physical package (6-DIP module, through-hole), feature set (remote on/off, OCP, SCP), dimensions, compliance requirements (RoHS, REACH, ECCN, HTSUS), and environmental ratings. Only parts matching these parameters are considered for substitution. The substitute part REC15-4815S/H2/M is grouped based on identical electrical and mechanical ratings and certified compliance.
Parameter Comparison
| Manufacturer Part Number | Series | Product Status | Type | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | Control Features | RoHS Status | MSL | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| REC15-4815S/H2 | ECONOLINE REC15 (15W) | Obsolete | Isolated Module | 1 | 36V | 75V | 15V | 1A | 15 W | 2 kV | ITE (Commercial) | Remote On/Off, OCP, SCP | -40°C ~ 71°C | 86% | Through Hole | 6-DIP Module | 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) | Enable, Active High | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 |
| REC15-4815S/H2/M | ECONOLINE REC15/M (15W) | Active | Isolated Module | 1 | 36V | 75V | 15V | 1A | 15 W | 2 kV | ITE (Commercial), Medical | Remote On/Off, OCP, SCP, UVLO | -40°C ~ 71°C | 86% | Through Hole | 6-DIP Module | 2.00" L x 1.00" W x 0.40" H (50.8mm x 25.4mm x 10.2mm) | Enable, Active High | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 |
Engineering Selection Recommendations
The primary selection criterion is product status. REC15-4815S/H2 is obsolete, while REC15-4815S/H2/M is active and maintains identical electrical, mechanical, and compliance parameters. Both parts conform to ROHS3 and REACH standards, possess the same ECCN and HTSUS codes, and match in mounting type, package, and size, ensuring a direct substitution while maintaining regulatory compliance.
Frequently Asked Questions (FAQ)
Q1: Can REC15-4815S/H2/M be used as a direct substitute for REC15-4815S/H2?
A1: REC15-4815S/H2/M matches all specified electrical, mechanical, and compliance parameters with REC15-4815S/H2, supporting direct substitution based on the provided data.
Q2: Are there differences in performance between the original and substitute models?
A2: Both the main and substitute parts have identical key ratings in input/output voltage, current, efficiency, mechanical package, and protection features.
Q3: Is the physical footprint and mounting style the same for both models?
A3: Yes, both use the 6-DIP module case with through-hole mounting and identical size/dimensions.
Q4: Does the substitute meet the same compliance and certification standards?
A4: Both parts are ROHS3 Compliant and REACH Unaffected and share ECCN and HTSUS classifications, confirming equivalence in regulatory compliance.
Q5: What is the consequence of the obsolete status for REC15-4815S/H2?
A5: Obsolete status means that REC15-4815S/H2 is no longer in active production, making it necessary to select an equivalent such as REC15-4815S/H2/M, which remains active.
Q6: Are there additional application certifications for the substitute part?
A6: REC15-4815S/H2/M additionally lists Medical applications; all other application and protection parameters align with the main part.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts