Part Overview

RBQ-12/33-D48NBS-C is an intermediate bus DC-DC converter from Murata Power Solutions Inc., designed for commercial ITE applications. The unit offers a single output of 11.85V at up to 33A, supports an input voltage range of 36V to 75V, and provides 391 W output power with high efficiency and through-hole mounting in a 1/4 brick 5-DIP module. The product has reached obsolete status, requiring selection of alternative models for ongoing designs and inventory fulfillment.

Substiute Parts

RBQ-12/33-D48NBS-C
Murata Power Solutions Inc.In Stock: 702RBQ-12/33-D48NBS-C Datasheet
RBQ-12/33-D48NBS-C
Current Part
DVQ0135V2NBSC
Murata Power Solutions Inc.In Stock: 971DVQ0135V2NBSC Datasheet
DVQ0135V2NBSC
MFR Recommended

Key Parameters

Manufacturer Part NumberManufacturerCategoryPackagingNumber of OutputsVoltage - Input (Min)Voltage - Input (Max)Voltage - Output 1Current - Output (Max)Power (Watts)Voltage - IsolationApplicationsFeaturesOperating TemperatureEfficiencyMounting TypePackage / CaseSize / DimensionProduct Status
RBQ-12/33-D48NBS-CMurata Power Solutions Inc.-136V75V11.85V33A391W2.25kVITE (Commercial)Remote On/Off, OCP, OTP, SCP, UVLO-40°C ~ 85°C96%Through Hole5-DIP Module, 1/4 Brick2.30" L x 1.45" W x 0.50" HObsolete

Substitute Part Grouping Explanation

Substitute parts are selected based strictly on the alignment of key electrical and mechanical parameters relevant to intermediate bus DC-DC converters for ITE (commercial) applications. Required matching parameters include input and output voltage ranges, maximum output current, output power rating, isolation voltage, mounting method, package type, dimensions, supported features, and operational temperature range. Only parts with equivalent or higher specifications within these criteria are considered valid substitutes.

Relevant key parameters for substitution:

  • Input Voltage Range (Min & Max)
  • Output Voltage & Current
  • Output Power
  • Isolation Voltage
  • Mounting Type
  • Package / Case
  • Features
  • Operating Temperature Range
  • Efficiency

Parameter Comparison

Manufacturer Part NumberManufacturerNumber of OutputsVoltage - Input (Min)Voltage - Input (Max)Voltage - Output 1Current - Output (Max)Power (Watts)Voltage - IsolationApplicationsFeaturesOperating TemperatureEfficiencyMounting TypePackage / CaseSize / DimensionProduct Status
RBQ-12/33-D48NBS-CMurata Power Solutions Inc.136V75V11.85V33A391W2.25kVITE (Commercial)Remote On/Off, OCP, OTP, SCP, UVLO-40°C ~ 85°C96%Through Hole5-DIP Module, 1/4 Brick2.30" L x 1.45" W x 0.50" HObsolete
DVQ0135V2NBSCMurata Power Solutions Inc.136V75V12V35A420W2.25kVITE (Commercial)Remote On/Off, OCP, OTP, OVP, SCP, UVLO-40°C ~ 85°C95.2%Through Hole16-DIP Module (15 Leads), 1/4 Brick2.30" L x 1.45" W x 0.52" HActive

Engineering Selection Recommendations

RBQ-12/33-D48NBS-C is obsolete. Substitute selection should prioritize active product status, available inventory, and provided compliance information such as RoHS and REACH status. DVQ0135V2NBSC is listed as ROHS3 compliant and currently active. Part certifications and compliance (including REACH and ECCN status) support usage in regulated environments as specified in the provided data.

Frequently Asked Questions (FAQ)

Q: What input and output voltage ranges must a substitute match for the RBQ-12/33-D48NBS-C?
A: Substitute models must provide a 36V to 75V input range and an output voltage close to or matching the original 11.85V specification.

Q: Is the output current and power rating critical for selecting DC-DC converter substitutes?
A: Output current and power specifications must be equivalent or higher than the original (33A, 391W) to ensure compatibility.

Q: What package or mounting type is required for full mechanical compatibility?
A: Through hole mounting and a 1/4 brick module format are required. Dimensional variance must remain within the stated size ranges.

Q: Are feature sets and protections relevant to substitution?
A: Features such as remote on/off, overcurrent, overtemperature, and short circuit protection must be supported, matching the original unit's functionality.

Q: What certifications or environmental compliance are required?
A: Substitute selection should comply with the specified RoHS, REACH, and ECCN designations provided in the input parameters.

Q: How does an obsolete status affect substitution?
A: Obsolete status requires selecting an active part with matched specifications for ongoing or new designs.

Q: Can the substitute part DVQ0135V2NBSC provide equivalent mechanical fit?
A: DVQ0135V2NBSC uses a 1/4 brick format with nearly identical dimensions as the original, supporting direct replacement in compatible PCB layouts.