Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts Reference for RB-0515S/H
Part Overview
RB-0515S/H from Recom Power is an isolated DC-DC converter module with a single 15V output, designed for applications including ITE (Commercial) and Medical. It operates within an input voltage range of 4.5V to 5.5V, delivering up to 66mA with a 1W power rating. The product is active and available in through-hole 7-SIP package. Locating alternative models is necessary to address supply chain requirements, multi-source qualification, or design flexibility while maintaining electrical and mechanical compatibility.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Description | Type | Applications | Product Status | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | MSL | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RB-0515S/H | Recom Power | DC DC CONVERTER 15V 1W | Isolated Module | ITE (Commercial), Medical | Active | 1 | 4.5V | 5.5V | 15V | 66mA | 1 W | 2 kV | SCP | -40°C ~ 85°C | 84% | Through Hole | 7-SIP Module, 5 Leads | 0.77" L x 0.24" W x 0.40" H (19.7mm x 6.0mm x 10.2mm) | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute grouping is determined by strict comparison of the following permitted parameters: product status, input voltage range, output voltage, output current, power, isolation voltage, applications, features, mounting type, package or case, operating temperature, and compliance data (RoHS, REACH, MSL, ECCN, HTSUS). Only parts meeting the provided criteria with active status and matching compliance are considered.
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Description | Type | Applications | Product Status | Number of Outputs | Voltage - Input (Min) | Voltage - Input (Max) | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Voltage - Isolation | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | RoHS Status | MSL | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RB-0515S/H | Recom Power | DC DC CONVERTER 15V 1W | Isolated Module | ITE (Commercial), Medical | Active | 1 | 4.5V | 5.5V | 15V | 66mA | 1 W | 2 kV | SCP | -40°C ~ 85°C | 84% | Through Hole | 7-SIP Module, 5 Leads | 0.77" L x 0.24" W x 0.40" H (19.7mm x 6.0mm x 10.2mm) | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 |
| MDS02L-15 | MEAN WELL USA Inc. | DC DC CONVERTER 15V 2W | Isolated Module | Medical | Active | 1 | 4.5V | 5.5V | 15V | 133mA | 2 W | 6 kV | SCP | -40°C ~ 85°C | 79% | Through Hole | 7-SIP Module, 4 Leads | 0.77" L x 0.39" W x 0.49" H (19.5mm x 9.8mm x 12.5mm) | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9580 |
Engineering Selection Recommendations
Both RB-0515S/H and MDS02L-15 are active products, meet ROHS3 compliance, are REACH unaffected, and have a Moisture Sensitivity Level of 1 (Unlimited). Both are classified with ECCN EAR99 and share the same HTSUS code. The provided compliance and regulatory data confirm that either part is suitable under standard qualifications using only specified parameters.
Frequently Asked Questions (FAQ)
Q: Which electrical specifications must match for DC-DC converter substitution?
A: Key electrical parameters are input voltage range, output voltage, number of outputs, output current capacity, power rating, isolation voltage, and operating temperature.
Q: How important is package compatibility in substitution?
A: Package/case type, mounting style, and dimensional details must match to ensure mechanical compatibility and seamless integration into the PCB.
Q: Is cross-manufacturer compliance data relevant for substitutes?
A: Yes. RoHS, REACH, ECCN, HTSUS, and Moisture Sensitivity Level approvals are mandatory for substitution under regulatory requirements.
Q: Can substitute parts be used in medical applications?
A: Yes, if the applications field includes “Medical” and compliance is present as provided in the input parameters.
Q: What is the significance of the product status field?
A: Only products listed as “Active” are eligible for substitution based on current availability and long-term support.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts

