RAC60-48SB Equivalent & Substitute Parts Reference

Part Overview

The RAC60-48SB by Recom Power is an AC/DC converter classified under enclosed AC DC converters, providing a single output of 48V at 1.25A and rated for 60W total power output. Input voltage specification is 85 ~ 265 VAC, with features suitable for ITE (Commercial) applications. The part is listed as obsolete, signifying that sourcing original units for new designs or ongoing maintenance may become increasingly difficult. Identifying alternatives with matching electrical and mechanical parameters is necessary for direct substitution in equipment bill of materials and repair operations.

Substiute Parts

RAC60-48SB
Recom PowerIn Stock: 1009RAC60-48SB Datasheet
RAC60-48SB
Current Part
RACM60-48SK/OF/PCB
Recom PowerIn Stock: 754RACM60-48SK/OF/PCB Datasheet
RACM60-48SK/OF/PCB
Similar
PSK-60D-48
CUI Inc.In Stock: 1114PSK-60D-48 Datasheet
PSK-60D-48
Similar

Key Parameters

Manufacturer Part Number Manufacturer Type Number of Outputs Voltage - Input Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Operating Temperature Efficiency Mounting Type RoHS Status Approval Agency Moisture Sensitivity Level (MSL) REACH Status
RAC60-48SB Recom Power Enclosed 1 85 ~ 265 VAC 48V 1.25A 60 W ITE (Commercial) -40°C ~ 70°C (With Derating) 86% Through Hole ROHS3 Compliant CE, cULus 1 REACH Unaffected

Substitute Part Grouping Explanation

Substitute selection for RAC60-48SB is based strictly on matching the following electrical and mechanical parameters: single output at 48V, rated output current of 1.25A, total output power of 60 W, input voltage range consistent with the original part, mounting type as through-hole, and compliance with ROHS3 and relevant approvals/certifications. Substitute candidates must also match the operating temperature range and application suitability (ITE, commercial, household appliances, medical) and maintain the same or better efficiency rating. Only parts meeting all these specifications are considered equivalent substitutes.

Parameter Comparison

Manufacturer Part Number Manufacturer Type Number of Outputs Voltage - Input Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Operating Temperature Efficiency Mounting Type RoHS Status Approval Agency Moisture Sensitivity Level (MSL) REACH Status
RAC60-48SB Recom Power Enclosed 1 85 ~ 265 VAC 48V 1.25A 60 W ITE (Commercial) -40°C ~ 70°C (With Derating) 86% Through Hole ROHS3 Compliant CE, cULus 1 REACH Unaffected
RACM60-48SK/OF/PCB Recom Power Open Frame 1 80 ~ 264 VAC, 120 ~ 370 VDC 48V 1.25A 60 W Household Appliances, ITE (Commercial), Medical -40°C ~ 85°C (With Derating) 90% Through Hole ROHS3 Compliant CE, cURus 1 REACH Unaffected
PSK-60D-48 CUI Inc. Enclosed 1 85 ~ 100 VAC, 305 ~ 430VDC 48V 1.25A 60 W Household Appliances, ITE (Commercial) -40°C ~ 85°C (With Derating) 91% Through Hole ROHS3 Compliant CE, UKCA 1 REACH Unaffected

Engineering Selection Recommendations

The RAC60-48SB is designated as obsolete, while both RACM60-48SK/OF/PCB and PSK-60D-48 are active and available in stock. All candidate substitute parts conform to ROHS3 requirements and have an unlimited Moisture Sensitivity Level (MSL 1). Regulatory approvals on substitutes include CE and either cURus or UKCA certifications. REACH status is unaffected for every listed product. Substitution should be performed only with parts matching these compliance and certification standards.

Frequently Asked Questions (FAQ)

Q1: What are the critical parameters for substituting the RAC60-48SB AC/DC converter?
A1: Key requirements include a single 48V output at 1.25A, 60W power rating, compatible input voltage range, through-hole mounting, compliance with ROHS3, and relevant approval agency certifications.

Q2: Does substitute selection require matching the enclosure type?
A2: Substitution is based on electrical and application parameters. Both enclosed and open-frame types are included when other functional criteria match.

Q3: Are substitute parts suitable for the same applications as the RAC60-48SB?
A3: Yes, all substitutes are rated for ITE (Commercial) and, where specified, additional sectors such as household appliances and medical applications.

Q4: Is the mounting style and package compatibility necessary in substitution?
A4: Yes. All substitutes provided are compatible with through-hole mounting as specified in the RAC60-48SB parameters.

Q5: Do substitute parts incorporate regulatory and compliance considerations?
A5: All parts listed are ROHS3 compliant, have an unlimited MSL, and hold relevant approval agency certifications (CE, cULus, cURus, UKCA) as required.