RAC60-15SB Equivalent & Substitute Parts Reference

Part Overview

The RAC60-15SB by Recom Power is an enclosed, single output AC/DC converter designed for ITE (Commercial) applications, offering 15V at 4A for a total of 60W power. This part is now classified as obsolete, making it necessary to identify alternative models that match its electrical and mechanical parameters for continuity in designs and inventory management. Proper selection of substitute models requires strict adherence to defined parameters, including input/output ratings, mounting method, regulatory approvals, package form factor, and compliance information.

Substiute Parts

RAC60-15SB
Recom PowerIn Stock: 1066RAC60-15SB Datasheet
RAC60-15SB
Current Part
RACM60-15SK/OF/PCB
Recom PowerIn Stock: 1233RACM60-15SK/OF/PCB Datasheet
RACM60-15SK/OF/PCB
Similar
PSK-60D-15
CUI Inc.In Stock: 1161PSK-60D-15 Datasheet
PSK-60D-15
Similar

Key Parameters

Parameter RAC60-15SB
Manufacturer Recom Power
Type Enclosed
Number of Outputs 1
Voltage - Input 85 ~ 265 VAC
Voltage - Output 1 15V
Current - Output (Max) 4A
Power (Watts) 60 W
Applications ITE (Commercial)
Operating Temperature -40°C ~ 70°C (With Derating)
Efficiency 86%
Mounting Type Through Hole
Package / Case 6-DIP Module
Size / Dimension 4.29" L x 2.30" W x 1.20" H (109.0mm x 58.5mm x 30.5mm)
Approval Agency CE, cULus
Line Regulation ±1%
Load Regulation ±1%
RoHS Status ROHS3 Compliant
MSL 1 (Unlimited)
REACH Status REACH Unaffected
ECCN EAR99
HTSUS 8504.40.9580

Substitute Part Grouping Explanation

Substitute AC/DC converters for RAC60-15SB are identified strictly based on the following parameters: form factor type (enclosed or open frame), number of outputs, voltage and current output specifications, total power rating, input voltage range, mounting type, regulatory agency approvals, and compliance with RoHS and REACH. Substitute components must match or exceed these specifications without deviation. Only parts with directly matching output voltage, output current, power rating, input range, and matching or compatible packaging and approvals are listed as substitutes.

Parameter Comparison

Parameter RAC60-15SB RACM60-15SK/OF/PCB PSK-60D-15
Manufacturer Recom Power Recom Power CUI Inc.
Type Enclosed Open Frame Enclosed
Number of Outputs 1 1 1
Voltage - Input 85 ~ 265 VAC 80 ~ 264 VAC, 120 ~ 370 VDC 85 ~ 100 VAC, 305 ~ 430VDC
Voltage - Output 1 15V 15V 15V
Current - Output (Max) 4A 4A 4A
Power (Watts) 60 W 60 W 60 W
Applications ITE (Commercial) Household Appliances, ITE (Commercial), Medical Household Appliances, ITE (Commercial)
Operating Temperature -40°C ~ 70°C (With Derating) -40°C ~ 85°C (With Derating) -40°C ~ 85°C (With Derating)
Efficiency 86% 90% 90%
Mounting Type Through Hole Through Hole Through Hole
Package / Case 6-DIP Module 7-DIP Module, 6 Leads 4-DIP Module
Size / Dimension 4.29" x 2.30" x 1.20" 3.09" x 2.09" x 1.39" 2.76" x 1.89" x 1.06"
Approval Agency CE, cULus CE, cURus CE, UKCA
Line Regulation ±1% ±0.05% ±1%
Load Regulation ±1% 0.5% ±1.5%
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
MSL 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected Not Provided
ECCN EAR99 EAR99 EAR99

Engineering Selection Recommendations

Selection among substitute AC/DC converters for RAC60-15SB should be based on product status (active vs. obsolete or not for new designs), compliance with ROHS3, and the presence of mandatory regulatory agency certifications (such as CE, cULus, cURus, UKCA). Substitute parts must match or exceed the environmental compliance requirements and must possess equivalent or broader regulatory approvals within the same application category.

Frequently Asked Questions (FAQ)

Q1: Which parameters are mandatory for the substitution of AC/DC converters in this category?
A1: Mandatory parameters include number of outputs, output voltage, output current, total power rating, input voltage range, mounting type, package form factor, regulatory agency approvals, and compliance status.

Q2: Does the substitute have to be of the same package type as the original?
A2: The substitute must have a mechanically and electrically compatible package type. While DIP module count may differ, the substitute must use through-hole mounting and fit within the mechanical constraints of the application.

Q3: Are all functional features (e.g., protection, certifications) matched between substitutes?
A3: Only provided features and certifications are matched. Substitute parts listed match output and input parameters, mounting, efficiency, environmental compliance, and reported regulatory agency approvals.

Q4: Is RoHS and REACH compliance required for all substitute parts?
A4: Yes. Substitute AC/DC converters must be ROHS3 compliant. REACH status has been provided where available.

Q5: How are differences in efficiency, line regulation, or load regulation addressed?
A5: Efficiency, line regulation, and load regulation are reported as provided. All substitutes listed have equal or superior performance in these parameters based on the provided data.

Q6: Can substitutes be used interchangeably in all cases?
A6: Substitution is strictly based on the parameters provided, including mechanical compatibility, electrical specifications, and certifications. Each listed substitute is matched by these parameters for functional equivalence within this product category.

Request Quote (Ships tomorrow)