Request Quote
(Ships tomorrow)
Recom Power RAC15-05SA Equivalent & Substitute Parts Reference
Part Overview
The Recom Power RAC15-05SA is an enclosed AC/DC converter classified under the POWERLINE RAC15-A (15W) series, offering 1 output at 5V and up to 3A. It is designed for ITE (Commercial) applications with a 90~264 VAC input range, SCP feature, and CE and cULus approval. The RAC15-05SA is currently marked as Obsolete, necessitating the evaluation and selection of alternative models with compatible electrical and mechanical specifications to maintain system reliability and regulatory compliance.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Series | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | Approval Agency | Line Regulation | Load Regulation | Weight | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RAC15-05SA | Recom Power | POWERLINE RAC15-A (15W) | Obsolete | Enclosed | 1 | 90 ~ 264 VAC | 5V | 3A | 15 W | ITE (Commercial) | SCP | -25°C ~ 70°C (With Derating) | 74% | Through Hole | 8-DIP Module, 5 Leads | 2.91" L x 2.13" W x 0.88" H (74.0mm x 54.0mm x 22.3mm) | CE, cULus | ±0.5% | ±0.5% | 0.251 lb (113.85 g) | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 |
Substitute Part Grouping Explanation
Substitution is determined strictly by matching key parameters relevant for the category of enclosed AC/DC converters. The following parameters define the selection logic:
- Output voltage and current rating
- Input voltage range
- Power rating (Watts)
- Number of outputs
- Output regulation
- Mounting type
- Package/case style
- Compliance and certification status
- Operating temperature range
Only substitute parts meeting or exceeding these parameters may be grouped as equivalents.
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Series | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | Approval Agency | Line Regulation | Load Regulation | Weight | RoHS Status | Moisture Sensitivity Level (MSL) | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RAC15-05SA | Recom Power | POWERLINE RAC15-A (15W) | Obsolete | Enclosed | 1 | 90 ~ 264 VAC | 5V | 3A | 15 W | ITE (Commercial) | SCP | -25°C ~ 70°C (With Derating) | 74% | Through Hole | 8-DIP Module, 5 Leads | 2.91" L x 2.13" W x 0.88" H (74.0mm x 54.0mm x 22.3mm) | CE, cULus | ±0.5% | ±0.5% | 0.251 lb (113.85 g) | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.6018 |
| RAC15-05SK | Recom Power | POWERLINE RAC15-K (15W) | Active | Enclosed | 1 | 85 ~ 264 VAC, 120 ~ 370 VDC | 5V | 3A | 15 W | Household Appliances, ITE (Commercial) | IP20, Universal Input | -40°C ~ 85°C (With Derating) | 84% | Through Hole | 5-DIP Module, 4 Leads | 2.07" L x 1.08" W x 0.91" H (52.5mm x 27.4mm x 23.0mm) | CE, cURus | ±1% | 1% | 0.132 lb (59.87 g) | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 | 8504.40.9510 |
Engineering Selection Recommendations
The RAC15-05SA is classified as Obsolete. Substitute selection should be based on product status, regulatory compliance, and maintained environmental certifications. The RAC15-05SK, with an Active status, ROHS3 and REACH compliance, and CE/cURus certification aligns with these requirements for continued use in regulated applications.
Frequently Asked Questions (FAQ)
Q: What are the primary electrical parameters to verify before substituting AC/DC converters?
A: Output voltage, maximum output current, total power rating, and input voltage range must be matched between main and substitute parts.
Q: How do package and mounting differences affect substitution?
A: Evaluate package/case type and mounting method to ensure mechanical compatibility with the existing system layout.
Q: Are certification and compliance requirements maintained in the substitute part?
A: Both RAC15-05SA and RAC15-05SK hold CE certifications and satisfy ROHS3 and REACH environmental requirements.
Q: What impact does product status have on selection?
A: Substitute selection is necessitated when the main part is Obsolete. An Active part with compatible parameters and certifications is required for reliable supply continuity.
Q: Is temperature range a critical substitution criterion?
A: The specified operating temperature range must meet or exceed application requirements as defined in the provided parameters.
Q: Is inventory quantity relevant to engineering substitution?
A: Inventory levels are not a technical substitution parameter but may affect availability for production or maintenance.
Q: Are substitute parts always physically identical?
A: Substitute parts must match key electrical and compliance parameters; physical package differences should be considered for mechanical fit.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts