Recom Power RAC15-05SA Equivalent & Substitute Parts Reference

Part Overview

The Recom Power RAC15-05SA is an enclosed AC/DC converter classified under the POWERLINE RAC15-A (15W) series, offering 1 output at 5V and up to 3A. It is designed for ITE (Commercial) applications with a 90~264 VAC input range, SCP feature, and CE and cULus approval. The RAC15-05SA is currently marked as Obsolete, necessitating the evaluation and selection of alternative models with compatible electrical and mechanical specifications to maintain system reliability and regulatory compliance.

Substiute Parts

RAC15-05SA
Recom PowerIn Stock: 881RAC15-05SA Datasheet
RAC15-05SA
Current Part
RAC15-05SK
Recom PowerIn Stock: 3112RAC15-05SK Datasheet
RAC15-05SK
Similar

Key Parameters

Manufacturer Part Number Manufacturer Series Product Status Type Number of Outputs Voltage - Input Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension Approval Agency Line Regulation Load Regulation Weight RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS
RAC15-05SA Recom Power POWERLINE RAC15-A (15W) Obsolete Enclosed 1 90 ~ 264 VAC 5V 3A 15 W ITE (Commercial) SCP -25°C ~ 70°C (With Derating) 74% Through Hole 8-DIP Module, 5 Leads 2.91" L x 2.13" W x 0.88" H (74.0mm x 54.0mm x 22.3mm) CE, cULus ±0.5% ±0.5% 0.251 lb (113.85 g) ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018

Substitute Part Grouping Explanation

Substitution is determined strictly by matching key parameters relevant for the category of enclosed AC/DC converters. The following parameters define the selection logic:

  • Output voltage and current rating
  • Input voltage range
  • Power rating (Watts)
  • Number of outputs
  • Output regulation
  • Mounting type
  • Package/case style
  • Compliance and certification status
  • Operating temperature range

Only substitute parts meeting or exceeding these parameters may be grouped as equivalents.

Parameter Comparison

Manufacturer Part Number Manufacturer Series Product Status Type Number of Outputs Voltage - Input Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension Approval Agency Line Regulation Load Regulation Weight RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS
RAC15-05SA Recom Power POWERLINE RAC15-A (15W) Obsolete Enclosed 1 90 ~ 264 VAC 5V 3A 15 W ITE (Commercial) SCP -25°C ~ 70°C (With Derating) 74% Through Hole 8-DIP Module, 5 Leads 2.91" L x 2.13" W x 0.88" H (74.0mm x 54.0mm x 22.3mm) CE, cULus ±0.5% ±0.5% 0.251 lb (113.85 g) ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.6018
RAC15-05SK Recom Power POWERLINE RAC15-K (15W) Active Enclosed 1 85 ~ 264 VAC, 120 ~ 370 VDC 5V 3A 15 W Household Appliances, ITE (Commercial) IP20, Universal Input -40°C ~ 85°C (With Derating) 84% Through Hole 5-DIP Module, 4 Leads 2.07" L x 1.08" W x 0.91" H (52.5mm x 27.4mm x 23.0mm) CE, cURus ±1% 1% 0.132 lb (59.87 g) ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9510

Engineering Selection Recommendations

The RAC15-05SA is classified as Obsolete. Substitute selection should be based on product status, regulatory compliance, and maintained environmental certifications. The RAC15-05SK, with an Active status, ROHS3 and REACH compliance, and CE/cURus certification aligns with these requirements for continued use in regulated applications.

Frequently Asked Questions (FAQ)

Q: What are the primary electrical parameters to verify before substituting AC/DC converters?
A: Output voltage, maximum output current, total power rating, and input voltage range must be matched between main and substitute parts.

Q: How do package and mounting differences affect substitution?
A: Evaluate package/case type and mounting method to ensure mechanical compatibility with the existing system layout.

Q: Are certification and compliance requirements maintained in the substitute part?
A: Both RAC15-05SA and RAC15-05SK hold CE certifications and satisfy ROHS3 and REACH environmental requirements.

Q: What impact does product status have on selection?
A: Substitute selection is necessitated when the main part is Obsolete. An Active part with compatible parameters and certifications is required for reliable supply continuity.

Q: Is temperature range a critical substitution criterion?
A: The specified operating temperature range must meet or exceed application requirements as defined in the provided parameters.

Q: Is inventory quantity relevant to engineering substitution?
A: Inventory levels are not a technical substitution parameter but may affect availability for production or maintenance.

Q: Are substitute parts always physically identical?
A: Substitute parts must match key electrical and compliance parameters; physical package differences should be considered for mechanical fit.

Request Quote (Ships tomorrow)