RAC10-15SC/277 Equivalent & Substitute Parts Reference
Part Overview
RAC10-15SC/277 by Recom Power is an enclosed AC/DC converter offering a single 15V output at 670mA, with an input voltage range of 80 ~ 305 VAC. It is currently designated as "Not For New Designs," indicating discontinuation or a restriction in future design-in applications. For ongoing production or new design requirements, alternative AC/DC converter models with matching key specifications are required to ensure direct compatibility and maintenance of approved electrical and mechanical parameters.
Substiute Parts
Key Parameters
| Parameter | RAC10-15SC/277 | IRM-10-15 |
|---|---|---|
| Output Voltage | 15V | 15V |
| Output Current (Max) | 670mA | 670mA |
| Power (Watts) | 10W | 10W |
| Input Voltage Range | 80 ~ 305 VAC | 85 ~ 305 VAC, 120 ~ 430 VDC |
| Number of Outputs | 1 | 1 |
| Efficiency | 78% | 82% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | 4-DIP Module | 4-DIP Module |
| Size / Dimension (mm) | 52.5 x 27.4 x 23.5 | 45.7 x 25.4 x 21.5 |
| Operating Temperature | -20°C ~ 70°C (With Derating) | -30°C ~ 70°C (With Derating) |
| Line Regulation | ±0.3% | ±0.3% |
| Load Regulation | ±0.5% | ±0.5% |
| Approval Agency | CE, cULus | CB, CE, cURus, EAC, TUV |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
Substitute Part Grouping Explanation
Substitute parts are identified and grouped based strictly on key electrical and mechanical parameters, including output voltage, output current, power rating, number of outputs, input voltage range, mounting type, package/case, efficiency, regulatory approvals, and environmental compliance. Only those models matching these defined parameters are listed as substitutes.
Parameter Comparison
| Parameter | RAC10-15SC/277 | IRM-10-15 |
|---|---|---|
| Output Voltage | 15V | 15V |
| Output Current (Max) | 670mA | 670mA |
| Power (Watts) | 10W | 10W |
| Input Voltage Range | 80 ~ 305 VAC | 85 ~ 305 VAC, 120 ~ 430 VDC |
| Number of Outputs | 1 | 1 |
| Efficiency | 78% | 82% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | 4-DIP Module | 4-DIP Module |
| Operating Temperature | -20°C ~ 70°C (With Derating) | -30°C ~ 70°C (With Derating) |
| Line Regulation | ±0.3% | ±0.3% |
| Load Regulation | ±0.5% | ±0.5% |
| Approval Agency | CE, cULus | CB, CE, cURus, EAC, TUV |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
Engineering Selection Recommendations
RAC10-15SC/277 holds a "Not For New Designs" status. When selecting substitutes such as IRM-10-15, ensure compliance with mandatory environmental standards ROHS3 and REACH. Both main and substitute parts have unrestricted moisture sensitivity levels and meet line/load regulation tolerances suitable for ITE (Commercial) applications. All substitute parts include required approval certifications for commercial deployment. Packaging approaches differ; accommodate system integration requirements accordingly.
Frequently Asked Questions (FAQ)
Which core parameters qualify IRM-10-15 as a substitute for RAC10-15SC/277?
IRM-10-15 matches RAC10-15SC/277’s output voltage, current rating, power rating, mounting type, package/case, efficiency, regulatory compliance, and environmental attributes.
Are both AC/DC converter modules in a comparable physical package?
Both modules utilize the "4-DIP Module" configuration for through-hole mounting. Dimensional size differs; confirm enclosure and PCB space compatibility.
Is the substitute compatible with the same commercial approval requirements?
IRM-10-15 provides commercial certifications including CB, CE, cURus, EAC, and TUV. RAC10-15SC/277 is approved to CE and cULus.
Do substitutions affect input voltage compatibility?
IRM-10-15 covers the original input VAC range and extends DC input support, ensuring compatibility within specified voltage ranges.
Do both modules comply with ROHS3 and REACH directives?
Both RAC10-15SC/277 and IRM-10-15 are ROHS3 compliant and REACH unaffected, meeting electrical and environmental standards.
Is there a difference in thermal or electrical regulation specifications?
Line and load regulation values are identical. Operating temperature ranges differ slightly, with IRM-10-15 supporting a wider minimum temperature.
Can substitute components be used in legacy designs?
Physical footprint, pinout, and electrical characteristics must be verified per system constraints. All listed substitute parts meet the specified attributes for standard replacement.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts