RAC10-05SA Equivalent & Substitute Parts Reference
Part Overview
The RAC10-05SA by Recom Power is an enclosed, through-hole AC/DC converter designed for ITE (Commercial) applications. It provides a single 5V output at 2A up to 10W, operating from a 90–264 VAC input range. Notable features include SCP (Short Circuit Protection), RoHS3 compliance, and approvals from CE and cULus. Due to its obsolete status, it is essential to reference equivalent and substitute AC/DC converters with matching electrical, mechanical, and regulatory parameters for sustaining designs and ensuring ongoing production.
Substiute Parts
Key Parameters
| Parameter | Main Part (RAC10-05SA) |
|---|---|
| Voltage - Input | 90 ~ 264 VAC |
| Voltage - Output 1 | 5V |
| Current - Output (Max) | 2A |
| Power (Watts) | 10 W |
| Number of Outputs | 1 |
| Applications | ITE (Commercial) |
| Mounting Type | Through Hole |
| Type | Enclosed |
| Approval Agency | CE, cULus |
| RoHS Status | ROHS3 Compliant |
| Operating Temperature | -25°C ~ 70°C (With Derating) |
| Efficiency | 71% |
| Regulation (Line / Load) | ±0.3% / ±0.5% |
| Size / Dimensions | 2.52" x 1.77" x 0.87" |
| Package / Case | 6-DIP Module, 5 Leads |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitute AC/DC converter models are selected based on matching electrical and mechanical attributes, regulatory compliance, and input/output specifications. Only the parameters explicitly provided are used to determine compatibility: input voltage range, output voltage and current ratings, power level, mounting type, number of outputs, type (enclosed), regulation, dimensions, package style, application, and agency approvals. Substitutes must also maintain RoHS status and relevant compliance for use in similar applications.
Parameter Comparison
| Parameter | RAC10-05SA | RAC10-05SC/277 | RAC10-05SK/277 |
|---|---|---|---|
| Voltage - Input | 90 ~ 264 VAC | 80 ~ 305 VAC | 80 ~ 305 VAC |
| Voltage - Output 1 | 5V | 5V | 5V |
| Current - Output (Max) | 2A | 2A | 2A |
| Power (Watts) | 10 W | 10 W | 10 W |
| Number of Outputs | 1 | 1 | 1 |
| Applications | ITE (Commercial) | ITE (Commercial) | Household Appliances, ITE (Commercial) |
| Mounting Type | Through Hole | Through Hole | Through Hole |
| Type | Enclosed | Enclosed | Enclosed |
| Approval Agency | CE, cULus | CE, cULus | CE, cURus |
| RoHS Status | ROHS3 Compliant | ROHS3 Compliant | ROHS3 Compliant |
| Operating Temperature | -25°C ~ 70°C (With Derating) | -20°C ~ 70°C (With Derating) | -40°C ~ 80°C (With Derating) |
| Efficiency | 71% | 78% | 82% |
| Regulation (Line / Load) | ±0.3% / ±0.5% | ±0.3% / -1.5% | ±0.5% / ±1.5% |
| Size / Dimensions | 2.52" x 1.77" x 0.87" | 2.07" x 1.08" x 0.93" | 2.07" x 1.08" x 0.93" |
| Package / Case | 6-DIP Module, 5 Leads | 4-DIP Module | 4-DIP Module |
| Product Status | Obsolete | Not For New Designs | Active |
Engineering Selection Recommendations
When selecting substitutes for the RAC10-05SA, only consider models that list explicit RoHS3 compliance, CE agency approval, and compatible through-hole, enclosed package construction. Electrical ratings for input and output, efficiency, and regulatory status must match or exceed the original component’s requirements. Availability and product status should be used to maintain continuity for designs that previously used the obsolete RAC10-05SA.
Frequently Asked Questions (FAQ)
Q: What are the most critical parameters when substituting RAC10-05SA in a design?
A: The key parameters are input voltage range, output voltage and current ratings, power output, mounting type, number of outputs, enclosure type, regulatory approvals (CE, RoHS3), and dimensions or package style.
Q: Are packaging and package/case format important for direct replacement?
A: Yes, package/case type (e.g., 6-DIP Module, 4-DIP Module) and pin configuration affect physical compatibility. Only specify dimensions and package details as provided.
Q: Does the approval agency or RoHS status affect substitution?
A: Substitute parts must match or exceed RoHS3 compliance and agency approvals (CE, cULus/cURus) for equivalent regulatory performance and compliance.
Q: Are substitutes available with the same or extended operating temperature ranges?
A: Substitute listings specify the exact operating temperature ranges and should be compared directly as provided.
Q: Can RAC10-05SC/277 or RAC10-05SK/277 be used if the application is commercial ITE?
A: Both RAC10-05SC/277 and RAC10-05SK/277 are specified for ITE (Commercial) applications, according to the provided information.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts