RAC05-15SA Equivalent & Substitute Parts Reference

Part Overview

The RAC05-15SA, manufactured by Recom Power, is an enclosed AC/DC converter featuring a single output of 15V at 333mA with a universal input voltage range of 90 ~ 264 VAC. The product offers 5W power output, through-hole mounting, and compliance with CE, cULus, and ROHS3 standards. Its operating temperature is specified as -25°C ~ 70°C (with derating), and the enclosure size is 2.17" x 1.77" x 0.82". The RAC05-15SA is classified as obsolete in inventory listings. In cases where the RAC05-15SA is unavailable, it is necessary to identify substitute parts with matching or compatible electrical, mechanical, and regulatory parameters.

Substiute Parts

RAC05-15SA
Recom PowerIn Stock: 802RAC05-15SA Datasheet
RAC05-15SA
Current Part
RAC05-15SK/277
Recom PowerIn Stock: 816RAC05-15SK/277 Datasheet
RAC05-15SK/277
Direct
RAC05-15SC
Recom PowerIn Stock: 1110RAC05-15SC Datasheet
RAC05-15SC
Similar
ECE10US15
XP PowerIn Stock: 724ECE10US15 Datasheet
ECE10US15
Similar

Key Parameters

Parameter RAC05-15SA Value
Manufacturer Recom Power
Category AC/DC Converter
Series POWERLINE RAC05-A (5W)
Product Status Obsolete
Type Enclosed
Number of Outputs 1
Voltage - Input 90 ~ 264 VAC
Voltage - Output 1 15V
Current - Output (Max) 333mA
Power (Watts) 5 W
Applications ITE (Commercial)
Features SCP
Operating Temperature -25°C ~ 70°C (With Derating)
Efficiency 70%
Mounting Type Through Hole
Package / Case 6-DIP Module, 5 Leads
Size / Dimension 2.17" x 1.77" x 0.82" (55.0mm x 45.0mm x 21.0mm)
Approval Agency CE, cULus
Line Regulation ±0.3%
Load Regulation ±0.5%
Weight 0.177 lb (80.29 g)
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
REACH Status REACH Unaffected
ECCN EAR99

Substitute Part Grouping Explanation

Substitute part selection for the RAC05-15SA is limited to models with equivalent or compatible key electrical and mechanical parameters, including output voltage (15V), output current capability, power rating (5W or greater), input voltage range, enclosure type, mounting style, approval agency certifications, RoHS and REACH compliance, operating temperature range, and package dimensions. Substitution is based strictly on these parameters with no inference or extrapolation. Substitute relationships listed are:

  • RAC05-15SK/277 (Direct Substitute)
  • RAC05-15SC (Similar Substitute)
  • ECE10US15 (Similar Substitute)

Parameter Comparison

Parameter RAC05-15SA RAC05-15SK/277 RAC05-15SC ECE10US15
Manufacturer Recom Power Recom Power Recom Power XP Power
Series POWERLINE RAC05-A (5W) POWERLINE RAC05-K/277 (5W) POWERLINE RAC05-C (5W) ECE (10W)
Product Status Obsolete Active Not For New Designs Active
Type Enclosed Enclosed Enclosed Enclosed
Number of Outputs 1 1 1 1
Voltage - Input 90 ~ 264 VAC 85 ~ 305 VAC, 120 ~ 430 VDC 90 ~ 264 VAC 85 ~ 264 VAC, 120 ~ 370 VDC
Voltage - Output 1 15V 15V 15V 15V
Current - Output (Max) 333mA 330mA 340mA 660mA
Power (Watts) 5 W 5 W 5 W 10 W
Applications ITE (Commercial) Household Appliances, ITE (Commercial) ITE (Commercial) ITE (Commercial)
Operating Temperature -25°C ~ 70°C (With Derating) -40°C ~ 85°C (With Derating) -25°C ~ 75°C (With Derating) -25°C ~ 70°C (With Derating)
Efficiency 70% 83% 76% 82%
Mounting Type Through Hole Through Hole Through Hole Through Hole
Package / Case 6-DIP Module, 5 Leads 9-DIP Module, 4 Leads 5-DIP Module, 4 Leads 4-DIP Module
Size / Dimension 2.17" x 1.77" x 0.82" 1.25" x 1.05" x 0.86" 2.17" x 1.77" x 0.82" 1.50" x 1.00" x 0.60"
Approval Agency CE, cULus CE, cURus CE, cULus, EN CSA, cUL, EN, UL
Line Regulation ±0.3% ±0.5% ±0.3% ±0.5%
Load Regulation ±0.5% 1% ±0.5% ±1%
Weight 0.177 lb (80.29 g) 0.069 lb (31.3 g) 0.077 lb (34.93 g) 0.053 lb (24.04 g)
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99 EAR99 EAR99

Engineering Selection Recommendations

Selection among substitute parts for the RAC05-15SA must be based on active product status, regulatory compliance, and relevant safety certifications. The RAC05-15SK/277 is an active product with CE and cURus approval, ROHS3 compliance, and a universal input range supporting ITE (Commercial) and household appliance applications. RAC05-15SC is not recommended for new designs. ECE10US15 is active with CSA, cUL, EN, UL approvals and ROHS3 compliance. All substitutes listed meet or exceed RoHS and REACH standards, providing suitable alternatives by compliance and certifications.

Frequently Asked Questions (FAQ)

Q1: What determines if a part is a valid substitute for RAC05-15SA?
A: Valid substitutes must have matching or compatible output voltage, output current, power rating, input voltage range, enclosure type, mounting method, and safety certifications. Regulatory compliance, such as RoHS and agency approvals, is also required.

Q2: Are package and mechanical dimensions considered in substitution?
A: Package type and size/dimensions are included among the substitution criteria; substitute parts must have compatible mechanical form factors for proper integration.

Q3: Why is product status critical in selecting an alternative?
A: Product status (active, obsolete, not for new designs) ensures ongoing availability and suitability for new builds or repairs according to inventory and manufacturer lifecycle data.

Q4: Do all substitutes support through-hole mounting?
A: Yes, all substitutes specified use through-hole mounting, consistent with the original RAC05-15SA.

Q5: Are there differences in certification between the RAC05-15SA and substitutes?
A: Approval agencies and certifications vary and are detailed in the parameter comparison table. Select substitutes with matching or required certifications for the application environment.

Request Quote (Ships tomorrow)