RAC03-3.3SA Equivalent & Substitute Parts Reference

Part Overview

The RAC03-3.3SA is an enclosed AC/DC converter from Recom Power, providing a single 3.3V output at up to 900mA with a maximum power rating of 3W. Designed for ITE (Commercial) applications, it features universal AC input (90–264 VAC) and is compliant with ROHS3 and REACH standards. This model is classified as obsolete, which necessitates the selection of alternative models to ensure continued product availability and design support.

Substiute Parts

RAC03-3.3SA
Recom PowerIn Stock: 924RAC03-3.3SA Datasheet
RAC03-3.3SA
Current Part
RAC03-3.3SC
Recom PowerIn Stock: 750RAC03-3.3SC Datasheet
RAC03-3.3SC
Similar

Key Parameters

ParameterValue
Manufacturer Part NumberRAC03-3.3SA
SeriesPOWERLINE RAC03-A (3W)
Product StatusObsolete
TypeEnclosed
Number of Outputs1
Voltage - Input90 ~ 264 VAC
Voltage - Output 13.3V
Current - Output (Max)900mA
Power (Watts)3 W
ApplicationsITE (Commercial)
FeaturesUniversal Input
Operating Temperature-40°C ~ 85°C (With Derating)
Efficiency70%
Mounting TypeThrough Hole
Package / Case4-SIP Module
Size / Dimension1.38" L x 0.71" W x 0.87" H (35.0mm x 18.0mm x 22.0mm)
Line Regulation±5%
Load Regulation±5%
RoHS StatusROHS3 Compliant
Moisture Sensitivity Level (MSL)1 (Unlimited)
REACH StatusREACH Unaffected

Substitute Part Grouping Explanation

Substitute parts for the RAC03-3.3SA are selected by strict equivalence in input voltage range, output voltage and current, power rating, mounting type, package style, compliance status, and application suitability. The following parameters are considered vital for equivalency: number of outputs, voltage–input, voltage–output, output current, wattage, mounting type, package/case, environmental compliance, and operating temperature.

Parameter Comparison

Parameter RAC03-3.3SA RAC03-3.3SC
Manufacturer Recom Power Recom Power
Description AC/DC CONVERTER 3.3V 3W AC/DC CONVERTER 3.3V 3W
Series POWERLINE RAC03-A (3W) POWERLINE RAC03-C (3W)
Product Status Obsolete Obsolete
Type Enclosed Enclosed
Number of Outputs 1 1
Voltage - Input 90 ~ 264 VAC 90 ~ 264 VAC
Voltage - Output 1 3.3V 3.3V
Current - Output (Max) 900mA 900mA
Power (Watts) 3 W 3 W
Applications ITE (Commercial) ITE (Commercial)
Features Universal Input Universal Input
Operating Temperature -40°C ~ 85°C (With Derating) -25°C ~ 85°C (With Derating)
Efficiency 70% 63%
Mounting Type Through Hole Through Hole
Package / Case 4-SIP Module 16-DIP Module, 5 Leads
Size / Dimension 1.38" L x 0.71" W x 0.87" H 1.49" L x 0.94" W x 0.64" H
Line Regulation ±5% ±3%
Load Regulation ±5% ±6%
Weight 0.057 lb (25.85 g) 0.066 lb (29.94 g)
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected

Engineering Selection Recommendations

The RAC03-3.3SA and RAC03-3.3SC are both obsolete but maintain compliance with ROHS3 and REACH regulations, and both are suitable for ITE (Commercial) environments. Selection among these options should consider regulatory compliance status, certification alignment, and inventory availability as provided. Packaging and form-factor differences can affect compatibility depending on the physical design constraints of the existing application.

Frequently Asked Questions (FAQ)

Q1: What are the key criteria for substituting RAC03-3.3SA with RAC03-3.3SC?
A1: Key substitution criteria include identical output voltage and current, input voltage range, power rating, mounting method, environmental compliance, and application suitability.

Q2: Are there any differences in packaging or mechanical layout?
A2: Yes, RAC03-3.3SA uses a 4-SIP Module while RAC03-3.3SC uses a 16-DIP Module, 5 Leads. Mechanical compatibility with the host PCB should be verified based on the given dimensions and package type.

Q3: Do both parts have equivalent regulatory and environmental compliance?
A3: Both RAC03-3.3SA and RAC03-3.3SC are ROHS3 compliant and REACH unaffected.

Q4: Are there efficiency differences to consider?
A4: RAC03-3.3SA has an efficiency of 70%, while RAC03-3.3SC specifies 63%. Power dissipation requirements should be assessed as needed.

Q5: What application categories are covered by these substitutes?
A5: Both models are rated for ITE (Commercial) use.

Q6: Is there a difference in the operating temperature range?
A6: RAC03-3.3SA supports -40°C to 85°C (with derating) while RAC03-3.3SC supports -25°C to 85°C (with derating). System requirements should be matched to these ranges based on application needs.

Request Quote (Ships tomorrow)