Equivalent & Substitute Parts for RAC03-05SC

Part Overview

The RAC03-05SC by Recom Power is an enclosed AC/DC converter delivering a single 5V output at up to 600mA from a universal input range of 90 ~ 264 VAC. This model is part of the POWERLINE RAC03-C (3W) series and is currently marked as obsolete. Finding suitable alternative models is necessary for maintaining design continuity, ensuring repairability of existing assemblies, and managing future procurement where the original part is unavailable.

Substiute Parts

RAC03-05SC
Recom PowerIn Stock: 2654RAC03-05SC Datasheet
RAC03-05SC
Current Part
RAC03E-05SK/277
Recom PowerIn Stock: 887RAC03E-05SK/277 Datasheet
RAC03E-05SK/277
MFR Recommended

Key Parameters

ParameterRAC03-05SC
ManufacturerRecom Power
SeriesPOWERLINE RAC03-C (3W)
Product StatusObsolete
TypeEnclosed
Number of Outputs1
Voltage - Input90 ~ 264 VAC
Voltage - Output 15V
Current - Output (Max)600mA
Power (Watts)3 W
ApplicationsITE (Commercial)
FeaturesUniversal Input
Operating Temperature-25°C ~ 85°C (With Derating)
Efficiency73%
Mounting TypeThrough Hole
Package / Case16-DIP Module, 5 Leads
Size / Dimension1.49" L x 0.94" W x 0.64" H
Approval AgencyCE, EN, UL
Standard Number60335-1; 60950-1
Line Regulation±3%
Load Regulation±6%
RoHS StatusROHS3 Compliant
MSL1 (Unlimited)
REACH StatusREACH Unaffected
ECCNEAR99
Inventory2580 Pcs

Substitute Part Grouping Explanation

Substitute selection is strictly determined by matching electrical and mechanical parameters: output voltage (5V), output current (600mA), input voltage range, power rating (3W), number of outputs (1), mounting type (Through Hole), and package format (module). Compliance and certification status are also considered for regulatory compatibility. Only parts with equal or greater capability per these specifications are included as substitutes.

Parameter Comparison

Parameter RAC03-05SC RAC03E-05SK/277
Manufacturer Recom Power Recom Power
Series POWERLINE RAC03-C (3W) POWERLINE RAC03-K/277 (3W)
Product Status Obsolete Active
Type Enclosed Enclosed
Number of Outputs 1 1
Voltage - Input 90 ~ 264 VAC 85 ~ 305 VAC, 120 ~ 430 VDC
Voltage - Output 1 5V 5V
Current - Output (Max) 600mA 600mA
Power (Watts) 3 W 3 W
Applications ITE (Commercial) ITE (Commercial)
Operating Temperature -25°C ~ 85°C (With Derating) -40°C ~ 85°C (With Derating)
Efficiency 73% 73%
Mounting Type Through Hole Through Hole
Package / Case 16-DIP Module, 5 Leads 4-DIP Module
Size / Dimension 1.49" L x 0.94" W x 0.64" H 1.33" L x 0.87" W x 0.61" H
Approval Agency CE, EN, UL CB, CE, cURus, EAC
Line Regulation ±3% ±0.5%
Load Regulation ±6% 0.5%
RoHS Status ROHS3 Compliant ROHS3 Compliant
MSL 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
Inventory 2580 Pcs 808 Pcs

Engineering Selection Recommendations

Substitution of the RAC03-05SC with RAC03E-05SK/277 is based on matching core operational parameters: voltage, current, power rating, mounting type, and compliance status. Both models are ROHS3 compliant and REACH unaffected, allowing unrestricted use in compliant applications. The substitute RAC03E-05SK/277 holds active product status and carries approvals including CB, CE, cURus, and EAC, supporting use in ITE (Commercial) environments. Certification and regulatory coverage on the substitute part meets the requirements established by the original part’s CE and UL listing.

Frequently Asked Questions (FAQ)

Q1: What is the most critical parameter when substituting an AC/DC converter module?
A1: The most critical parameters are output voltage, output current, power rating, input voltage range, mounting type, and package compatibility. All must be matched for direct substitution.

Q2: Does the RAC03E-05SK/277 fit in place of RAC03-05SC from a mechanical perspective?
A2: Both models utilize a through-hole mounting type and enclosed package. Dimensional differences exist and should be verified against layout requirements based solely on the provided mechanical parameters.

Q3: Are there compliance or certification differences between RAC03-05SC and RAC03E-05SK/277?
A3: RAC03-05SC carries CE, EN, UL approvals; RAC03E-05SK/277 is approved by CB, CE, cURus, and EAC. Both meet ROHS3 and REACH criteria.

Q4: Can the substitute part be used in the same ITE (Commercial) applications?
A4: Both the main and substitute parts are stated for ITE (Commercial) applications.

Q5: If the original part is obsolete, can RAC03E-05SK/277 be directly ordered for replacement?
A5: RAC03E-05SK/277 is listed as active status in inventory and carries matched core electrical and regulatory parameters for direct substitution.

Request Quote (Ships tomorrow)