Request Quote
(Ships tomorrow)
RAC02-3.3SC Equivalent & Substitute Parts Reference
Part Overview
The RAC02-3.3SC from Recom Power is an enclosed AC/DC converter offering a single 3.3V output at up to 600mA (2W). It is designed for ITE (Commercial) applications, features short circuit protection (SCP), and operates over an input voltage range of 80–264 VAC. The module comes in a through-hole 4-DIP package. The product status is Obsolete, making it necessary to identify equivalent and substitute models with matching electrical, mechanical, and compliance parameters.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Series | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | Approval Agency | Line Regulation | Load Regulation | RoHS Status | MSL | REACH Status | ECCN |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RAC02-3.3SC | POWERLINE RAC02-C (2W) | Enclosed | 1 | 80 ~ 264 VAC | 3.3V | 600mA | 2 W | ITE (Commercial) | SCP | -25°C ~ 85°C (With Derating) | 66% | Through Hole | 4-DIP Module | 1.33" L x 0.87" W x 0.71" H (33.7mm x 22.2mm x 18.0mm) | CE, EN, UL | ±2% | ±6% | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 |
Substitute Part Grouping Explanation
Substitution is determined strictly according to the following key parameters: Number of Outputs, Output Voltage, Output Current, Input Voltage Range, Power Rating, Package/Case, Mounting Type, Application Category, Operating Temperature Range, Compliance (RoHS, REACH), Moisture Sensitivity Level, and Certification Status. Substitute parts must match or exceed the values and standards specified for these parameters to ensure form, fit, and function.
Parameter Comparison
| Manufacturer Part Number | Series | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | Approval Agency | Line Regulation | Load Regulation | RoHS Status | MSL | REACH Status | ECCN |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RAC02-3.3SC | POWERLINE RAC02-C (2W) | Enclosed | 1 | 80 ~ 264 VAC | 3.3V | 600mA | 2 W | ITE (Commercial) | SCP | -25°C ~ 85°C (With Derating) | 66% | Through Hole | 4-DIP Module | 1.33" L x 0.87" W x 0.71" H | CE, EN, UL | ±2% | ±6% | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 |
| RAC02E-3.3SK/277 | POWERLINE RAC02-K/277 (2W) | Enclosed | 1 | 85 ~ 305 VAC, 120 ~ 430 VDC | 3.3V | 600mA | 2 W | ITE (Commercial) | Baseplate, Standby Output | -40°C ~ 90°C (With Derating) | 68% | Through Hole | 4-DIP Module | 1.33" L x 0.87" W x 0.61" H | CB, CE, cURus, EAC | ±0.5% | 0.5% | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected | EAR99 |
Engineering Selection Recommendations
The RAC02-3.3SC is an obsolete product. Substitute selection should be based on product status (Active/Obsolete), RoHS compliance, REACH compliance, moisture sensitivity level (MSL), and required safety or performance certification approvals. Substitute models listed maintain equivalent regulatory compliance and certification status as specified.
Frequently Asked Questions (FAQ)
Q1: What key parameters must match for a substitute AC/DC converter to be considered equivalent to RAC02-3.3SC?
A1: Number of outputs, output voltage, output current, power rating, input voltage range, package/case, mounting type, application category, operating temperature, RoHS/REACH compliance, moisture sensitivity level, and certifications.
Q2: Are there significant differences in package dimensions or mounting between RAC02-3.3SC and RAC02E-3.3SK/277?
A2: Both use 4-DIP modules and through-hole mounting. The main variance is in height, with RAC02E-3.3SK/277 being shorter (0.61" vs. 0.71").
Q3: Is the substitute part compatible with existing regulatory and compliance requirements?
A3: The substitute part maintains ROHS3 compliance, REACH unaffected status, and includes relevant safety and quality certification approvals.
Q4: Can the substitute part be used in identical application environments?
A4: The substitute part matches the key application and environmental parameters, including input/output voltage, current, package, and ITE (Commercial) category.
Q5: Does changing to the substitute part require changes to PCB layout or assembly process?
A5: Both parts employ a 4-DIP module and through-hole mounting, minimizing mechanical changes. Dimensional differences should be assessed strictly by the noted size information.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts