The RAC02-15SC by Recom Power is an enclosed AC/DC converter designed to supply 15V at up to 133mA with an output power of 2W. It operates from an input voltage range of 80 ~ 264 VAC, featuring short circuit protection and compliance with multiple approval agencies. The product status is marked as obsolete, making it necessary for designers, buyers, and maintenance engineers to identify substitute or equivalent models maintaining equivalent functionality and compliance.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Manufacturer | Description | Series | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Applications | Features | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | Approval Agency | Line Regulation | Load Regulation | RoHS Status | MSL | REACH Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RAC02-15SC | Recom Power | AC/DC CONVERTER 15V 2W | POWERLINE RAC02-C (2W) | Obsolete | Enclosed | 1 | 80 ~ 264 VAC | 15V | 133mA | 2 W | ITE (Commercial) | SCP | -25°C ~ 85°C (With Derating) | 74% | Through Hole | 4-DIP Module | 1.33" L x 0.87" W x 0.71" H (33.7mm x 22.2mm x 18.0mm) | CE, EN, UL | ±2% | ±6% | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected |
Substitute Part Grouping Explanation
Substitute models for the RAC02-15SC are grouped strictly on the basis of matching key functional parameters. Required matching parameters for substitution include output voltage, output current, output power, input voltage range, operating temperature, mounting type, package, regulatory compliance, and RoHS/REACH/agency approvals. Only parts that are equivalent in these regards and provided in the input list are considered suitable substitutes.
Parameter Comparison
| Manufacturer Part Number | Manufacturer | Description | Series | Product Status | Type | Number of Outputs | Voltage - Input | Voltage - Output 1 | Current - Output (Max) | Power (Watts) | Applications | Operating Temperature | Efficiency | Mounting Type | Package / Case | Size / Dimension | Approval Agency | Line Regulation | Load Regulation | RoHS Status | MSL | REACH Status |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RAC02-15SC | Recom Power | AC/DC CONVERTER 15V 2W | POWERLINE RAC02-C (2W) | Obsolete | Enclosed | 1 | 80 ~ 264 VAC | 15V | 133mA | 2 W | ITE (Commercial) | -25°C ~ 85°C (With Derating) | 74% | Through Hole | 4-DIP Module | 1.33" L x 0.87" W x 0.71" H (33.7mm x 22.2mm x 18.0mm) | CE, EN, UL | ±2% | ±6% | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected |
| RAC02E-15SK/277 | Recom Power | AC/DC CONVERTER 15V 2W | POWERLINE RAC02-K/277 (2W) | Active | Enclosed | 1 | 85 ~ 305 VAC, 120 ~ 430 VDC | 15V | 133mA | 2 W | ITE (Commercial) | -40°C ~ 90°C (With Derating) | 75% | Through Hole | 4-DIP Module | 1.33" L x 0.87" W x 0.61" H (33.7mm x 22.2mm x 15.4mm) | CB, CE, cURus, EAC | ±0.5% | 0.5% | ROHS3 Compliant | 1 (Unlimited) | REACH Unaffected |
Engineering Selection Recommendations
Selection of a substitute part is determined by product status, compliance status, and provided certifications. The RAC02-15SC is marked as obsolete, while RAC02E-15SK/277 is listed as active and ROHS3 compliant. Both models conform to REACH requirements, feature through-hole mounting, a 4-DIP module case, and possess regulatory approvals relevant to ITE (Commercial) applications. Substitute selection is fully supported by the provided regulatory and compliance characteristics.
Frequently Asked Questions (FAQ)
Q1: What parameters must match when selecting a substitute for RAC02-15SC?
A1: Output voltage, output current, output power, input voltage range, package type, mounting method, operating temperature, approval agency compliance, RoHS status, and REACH status are primary considerations.
Q2: Is the RAC02E-15SK/277 a direct mechanical replacement for the RAC02-15SC?
A2: Both parts share the 4-DIP module package and through-hole mounting type. Size/dimension details should be compared directly as provided.
Q3: How does approval and compliance affect substitute selection?
A3: Substitute parts must meet or exceed the same approval agency certifications (e.g., CE, UL, cURus) and maintain current RoHS and REACH compliance.
Q4: Are thermal specifications or efficiency different between RAC02-15SC and RAC02E-15SK/277?
A4: Only the specified efficiency and operating temperature parameters should be considered. Review matching values as documented in the parameter comparison table.
Q5: Can the substitute be used in the same ITE (Commercial) applications?
A5: Provided parameters confirm shared application suitability (ITE, Commercial use) for both main and substitute parts.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts