Equivalent & Substitute Parts Reference: R-78B1.8-1.5

Part Overview

Manufacturer part number R-78B1.8-1.5, produced by Recom Power, is a DC-DC converter designed as a linear regulator replacement. It features a single 1.8V output at up to 1.5A with a 2.7W maximum power rating and supports input voltages from 4.75V to 18V. The module is RoHS3 compliant and suitable for ITE (Commercial) applications. This product is now classified as Obsolete, necessitating the identification of alternative models to maintain design continuity, replenishment, or ongoing support in manufacturing and repair environments.

Substiute Parts

R-78B1.8-1.5
Recom PowerIn Stock: 12238R-78B1.8-1.5 Datasheet
R-78B1.8-1.5
Current Part
R-78B1.8-2.0
Recom PowerIn Stock: 984R-78B1.8-2.0 Datasheet
R-78B1.8-2.0
Direct

Key Parameters

Manufacturer Part Number Manufacturer Series Product Status Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Features Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension RoHS Status MSL REACH Status ECCN HTSUS
R-78B1.8-1.5 Recom Power INNOLINE R-78B-1.5 Obsolete Linear Regulator Replacement 1 4.75V 18V 1.8V 1.5A 2.7 W ITE (Commercial) OTP, SCP -40°C ~ 85°C 85% Through Hole 3-SIP Module 0.45" L x 0.33" W x 0.69" H (11.5mm x 8.5mm x 17.5mm) ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9580

Substitute Part Grouping Explanation

Substitute parts are grouped based on strict equivalence of critical parameters including: manufacturer series, output voltage, number of outputs, input voltage range, mounting type, package dimensions, regulatory compliance (RoHS status, REACH status), and matching application types. All parameters used for grouping are present in both the main and substitute part specifications and match the requirements to ensure electrical and mechanical compatibility.

Parameter Comparison

Parameter Main Part: R-78B1.8-1.5 Substitute: R-78B1.8-2.0
Manufacturer Recom Power Recom Power
Series INNOLINE R-78B-1.5 INNOLINE R-78B-2.0
Product Status Obsolete Active
Type Linear Regulator Replacement Linear Regulator Replacement
Number of Outputs 1 1
Voltage - Input (Min) 4.75V 4.75V
Voltage - Input (Max) 18V 32V
Voltage - Output 1 1.8V 1.8V
Current - Output (Max) 1.5A 2A
Applications ITE (Commercial) ITE (Commercial)
Features OTP, SCP OTP, SCP
Operating Temperature -40°C ~ 85°C -40°C ~ 70°C
Efficiency 85% 91%
Mounting Type Through Hole Through Hole
Package / Case 3-SIP Module 3-SIP Module
Size / Dimension 0.45" L x 0.33" W x 0.69" H (11.5mm x 8.5mm x 17.5mm) 0.45" L x 0.33" W x 0.69" H (11.5mm x 8.5mm x 17.5mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
MSL 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

Based on the product status, the main part R-78B1.8-1.5 is obsolete, while the substitute R-78B1.8-2.0 is listed as active. Both the main and substitute parts are ROHS3 compliant and REACH unaffected, with the same Moisture Sensitivity Level (1, Unlimited). Selection should be made in accordance with these status, compliance, and certification parameters, strictly referencing information supplied.

Frequently Asked Questions (FAQ)

Q1: What parameters are critical when selecting a substitute for R-78B1.8-1.5?
A1: Only parameters explicitly listed in the data above—including output voltage, output current, input voltage range, features, package, dimensions, mounting type, operating temperature, RoHS status, MSL, and REACH status—are used for determining suitability as a substitute.

Q2: Is the R-78B1.8-2.0 directly compatible in terms of pinout and physical footprint?
A2: According to the provided inputs, both the R-78B1.8-1.5 and R-78B1.8-2.0 utilize a 3-SIP Module package and have identical dimensions and through-hole mounting, indicating physical and pin-for-pin compatibility.

Q3: Are there differences in regulatory or environmental compliance between the original and substitute parts?
A3: Both parts are ROHS3 compliant, have an MSL of 1 (Unlimited), and are REACH unaffected.

Q4: Does the operating temperature or electrical performance differ?
A4: The main part R-78B1.8-1.5 operates from -40°C to 85°C, while the substitute R-78B1.8-2.0 operates from -40°C to 70°C as per provided data. Other parameters including output voltage, package type, and application match.

Q5: Is the substitute part status suitable for new designs or lifecycle extension?
A5: The substitute R-78B1.8-2.0 is designated as Active, in contrast to the Obsolete status of the main part.