Equivalent & Substitute Parts Reference: R12P12D/P/R6.4

Part Overview

The Recom Power R12P12D/P/R6.4 is an active isolated module DC-DC converter designed for ITE (Commercial) and Medical applications. It provides dual outputs of +12V and -12V at 41mA each, with a wide input range of 10.8V to 13.2V and high isolation rating of 6.4 kV. The device features short-circuit protection (SCP), through-hole mounting, and is housed in a 7-SIP Module, 5 Leads case. Due to design revisions, supply chain preferences, or inventory fluctuations, it is necessary to identify alternative models that meet the strict electrical, mechanical, and compliance requirements of this product category.

Substiute Parts

R12P12D/P/R6.4
Recom PowerIn Stock: 986R12P12D/P/R6.4 Datasheet
R12P12D/P/R6.4
Current Part
MDD01M-12
MEAN WELL USA Inc.In Stock: 1030MDD01M-12 Datasheet
MDD01M-12
Direct

Key Parameters

Parameter Main Part Value
Manufacturer Part Number R12P12D/P/R6.4
Series ECONOLINE RxxPxx/R (1W)
Description DC DC CONVERTER +/-12V 1W
Type Isolated Module
Number of Outputs 2
Voltage - Input (Min) 10.8V
Voltage - Input (Max) 13.2V
Voltage - Output 1 12V
Voltage - Output 2 -12V
Current - Output (Max) 41mA, 41mA
Power (Watts) 1 W
Voltage - Isolation 6.4 kV
Applications ITE (Commercial), Medical
Features SCP
Operating Temperature -40°C ~ 85°C
Efficiency 82%
Mounting Type Through Hole
Package / Case 7-SIP Module, 5 Leads
Size / Dimension 0.77" L x 0.39" W x 0.49" H (19.7mm x 9.8mm x 12.5mm)
RoHS Status ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
REACH Status REACH Unaffected
ECCN EAR99
HTSUS 8504.40.9580

Substitute Part Grouping Explanation

Substitution is determined strictly according to the following key electrical and mechanical parameters: input voltage range, output voltages and currents, isolation voltage, total output power, mounting type, package/case dimensions, and relevant compliance status. Substitutes must also be active devices that match application suitability and features such as SCP. Only parts matching both performance and compliance parameters are included.

Parameter Comparison

Parameter R12P12D/P/R6.4 (Recom Power) MDD01M-12 (MEAN WELL USA Inc.)
Description DC DC CONVERTER +/-12V 1W DC DC CONVERTER +/-12V 1W
Type Isolated Module Isolated Module
Number of Outputs 2 2
Voltage - Input (Min) 10.8V 10.8V
Voltage - Input (Max) 13.2V 13.2V
Voltage - Output 1 12V 12V
Voltage - Output 2 -12V -12V
Current - Output (Max) 41mA, 41mA 42mA, 42mA
Power (Watts) 1 W 1 W
Voltage - Isolation 6.4 kV 6 kV
Applications ITE (Commercial), Medical Medical
Features SCP SCP
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Efficiency 82% 75%
Mounting Type Through Hole Through Hole
Package / Case 7-SIP Module, 5 Leads 7-SIP Module, 5 Leads
Size / Dimension 0.77" L x 0.39" W x 0.49" H (19.7mm x 9.8mm x 12.5mm) 0.77" L x 0.39" W x 0.49" H (19.5mm x 9.8mm x 12.5mm)
RoHS Status ROHS3 Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

Both R12P12D/P/R6.4 and MDD01M-12 are listed as active products with ROHS3 compliance, REACH unaffected status, ECCN EAR99, and unlimited moisture sensitivity level (MSL 1). This ensures suitability for designs requiring environmental compliance and certification consistency for commercial and medical applications. The substitute offers matching input voltage, output voltages and power rating, and similar mounting and package types.

Frequently Asked Questions (FAQ)

Q1: What parameters must match for substituting R12P12D/P/R6.4?
A1: Input voltage range, output voltages, output currents, isolation voltage, package type, mounting method, compliance status, and operating temperature range must be identical or within specified tolerances.

Q2: Are the package and mounting types compatible between R12P12D/P/R6.4 and MDD01M-12?
A2: Both use the 7-SIP Module, 5 Leads package with through-hole mounting; dimensions are similar, supporting direct mechanical substitution.

Q3: What compliance certifications are present?
A3: Both models are ROHS3 compliant, REACH unaffected, with an unrestricted moisture sensitivity level and ECCN EAR99 classification.

Q4: Do substitute parts provide equivalent output performance?
A4: Substitute parts must provide matching output voltages, currents, and power ratings, as demonstrated in the parameter comparison above.

Q5: What features are ensured with substitute selection in this category?
A5: Required features such as SCP (Short Circuit Protection), specified operating temperature, and dual outputs are preserved in listed substitutes.