PV14-8LFX-C Equivalent & Substitute Parts

Part Overview

The PV14-8LFX-C is a blue insulated spade terminal connector manufactured by Panduit Corp, designed for crimp termination of 14-16 AWG wire onto an 8 stud. This component is classified as obsolete, indicating that direct procurement from original inventory may become unavailable. Substitute parts are necessary to maintain design continuity and ensure uninterrupted supply chain access for applications requiring equivalent electrical and mechanical performance.

Substiute Parts

PV14-8LFX-C
Panduit CorpIn Stock: 648PV14-8LFX-C Datasheet
PV14-8LFX-C
Current Part
P14-8LF-M
Panduit CorpIn Stock: 2503P14-8LF-M Datasheet
P14-8LF-M
MFR Recommended
PV14-8LF-C
Panduit CorpIn Stock: 3004PV14-8LF-C Datasheet
PV14-8LF-C
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number PV14-8LFX-C
Manufacturer Panduit Corp
Category Terminals
Terminal Type Spring, Snap
Stud/Tab Size 8 Stud
Wire Gauge 14-16 AWG
Termination Method Crimp
Insulation Type Insulated
Color Blue
Contact Material Copper
Contact Finish Tin
Product Status Obsolete
RoHS Status ROHS3 Compliant

Substitute Part Grouping Explanation

Substitution eligibility for the PV14-8LFX-C is determined by the following critical parameters:

Core Electrical Parameters:

  • Wire gauge range: 14-16 AWG
  • Stud size: 8 stud
  • Contact material: Copper
  • Contact finish: Tin
  • Termination method: Crimp

Core Mechanical Parameters:

  • Terminal type: Spring, Snap
  • Insulation requirement: Insulated
  • Color specification: Blue
  • Mounting type: Free Hanging (In-Line)

Compliance Parameters:

  • RoHS3 Compliance
  • REACH Unaffected status
  • ECCN: EAR99

Substitute parts must satisfy all core electrical and mechanical parameters while maintaining compliance certifications. Dimensional variations within the specified wire gauge and stud size are permissible when the functional interface remains compatible.

Parameter Comparison

Parameter PV14-8LFX-C (Main) P14-8LF-M (Substitute) PV14-8LF-C (Substitute)
Manufacturer Part Number PV14-8LFX-C P14-8LF-M PV14-8LF-C
Manufacturer Panduit Corp Panduit Corp Panduit Corp
Product Status Obsolete Active Active
Terminal Type Spring, Snap Spring, Snap Spring, Snap
Stud/Tab Size 8 Stud 8 Stud 8 Stud
Wire Gauge 14-16 AWG 14-16 AWG 14-16 AWG
Termination Method Crimp Crimp Crimp
Insulation Type Insulated Non-Insulated Insulated
Color Blue Not Applicable Blue
Contact Material Copper Copper Copper
Contact Finish Tin Tin Tin
Mounting Type Free Hanging (In-Line) Free Hanging (In-Line) Free Hanging (In-Line)
Features Brazed Seam, Serrated Termination Brazed Seam, Serrated Termination Brazed Seam, Serrated Termination
RoHS Status ROHS3 Compliant ROHS3 Compliant ROHS3 Compliant
REACH Status REACH Unaffected REACH Unaffected REACH Unaffected
Length - Overall 1.010" (25.65mm) 0.770" (19.56mm) 0.970" (24.64mm)
Width - Outer Edges 0.290" (7.37mm) 0.290" (7.37mm) 0.290" (7.37mm)

Engineering Selection Recommendations

Primary Substitute: PV14-8LF-C

The PV14-8LF-C is the preferred substitute for the obsolete PV14-8LFX-C. Both components share identical core electrical specifications (14-16 AWG wire gauge, 8 stud size, copper with tin finish), insulation type (insulated vinyl), and color (blue). Both maintain ROHS3 compliance and REACH unaffected status. The PV14-8LF-C is currently in active production status with 2909 units in stock, ensuring supply continuity. The overall length differs by 0.040" (1.01mm), which falls within acceptable dimensional tolerance for free-hanging in-line mounting applications.

Secondary Substitute: P14-8LF-M

The P14-8LF-M is a non-insulated variant that shares the same wire gauge, stud size, contact material, and contact finish as the main part. This substitute is suitable only for applications where insulation is not required or where the terminal will be used in an insulated assembly. The P14-8LF-M is in active production with 2416 units in stock. The absence of insulation and color specification distinguishes this part from the primary substitute.

Both substitute parts maintain full compliance with RoHS3 and REACH requirements, matching the regulatory status of the obsolete main part.

Frequently Asked Questions (FAQ)

Q: Can P14-8LF-M be used as a direct replacement for PV14-8LFX-C?

A: P14-8LF-M is not a direct replacement. While it matches the wire gauge (14-16 AWG), stud size (8), and contact specifications, it is non-insulated. The PV14-8LFX-C is insulated with blue vinyl. Use P14-8LF-M only in applications where insulation is not required or where the terminal will be housed in an insulated connector body.

Q: What is the primary difference between PV14-8LF-C and PV14-8LFX-C?

A: Both are blue insulated 8 stud spade terminals for 14-16 AWG wire. The primary difference is overall length: PV14-8LFX-C measures 1.010" (25.65mm) while PV14-8LF-C measures 0.970" (24.64mm). This 0.040" difference is within acceptable tolerance for free-hanging in-line mounting applications. The PV14-8LF-C is in active production, whereas PV14-8LFX-C is obsolete.

Q: Are all substitute parts RoHS3 compliant?

A: Yes. Both P14-8LF-M and PV14-8LF-C are ROHS3 compliant and REACH unaffected, matching the compliance status of the main part PV14-8LFX-C.

Q: What wire gauges are supported by these terminals?

A: All three parts (main and substitutes) support 14-16 AWG wire gauge. Do not use these terminals with wire gauges outside this range.

Q: Does the 0.040" length difference between PV14-8LFX-C and PV14-8LF-C affect compatibility?

A: The length difference does not affect electrical compatibility or stud interface. For free-hanging in-line mounting applications, this dimensional variation is acceptable. Verify physical clearance in your specific assembly if space constraints exist.

Q: What is the stud size for all these terminals?

A: All three parts feature an 8 stud, which is the mechanical interface point for connection to the mating component.

Q: Can these terminals be used with wire gauges smaller than 14 AWG?

A: No. These terminals are rated for 14-16 AWG wire only. Using smaller gauge wire will result in improper crimp and unreliable electrical connection.

Request Quote (Ships tomorrow)