PV14-6SLF-M Equivalent & Substitute Parts

Part Overview

The PV14-6SLF-M is a blue insulated spade terminal connector manufactured by Panduit Corp, designed for crimp termination of 14-16 AWG wire to a 6 stud configuration. This component is classified as obsolete, necessitating identification of active equivalent parts for ongoing procurement and system maintenance. The terminal features a spring snap mounting type with tin-plated copper contacts and vinyl insulation, suitable for free-hanging in-line applications.

Substiute Parts

PV14-6SLF-M
Panduit CorpIn Stock: 976PV14-6SLF-M Datasheet
PV14-6SLF-M
Current Part
PV14-6LF-M
Panduit CorpIn Stock: 9484PV14-6LF-M Datasheet
PV14-6LF-M
Similar
52955-1
TE Connectivity AMP ConnectorsIn Stock: 3987352955-1 Datasheet
52955-1
Similar

Key Parameters

Parameter Value
Wire Gauge 14-16 AWG
Stud/Tab Size 6 Stud
Terminal Type Spring, Snap
Termination Method Crimp
Insulation Type Insulated
Color Blue
Contact Material Copper
Contact Finish Tin
Mounting Type Free Hanging (In-Line)
Tongue Inside Opening 0.140" (3.56mm)

Substitute Part Grouping Explanation

Substitution eligibility for the PV14-6SLF-M is determined by strict alignment of the following critical parameters:

Primary Compatibility Criteria:

  • Wire gauge range: 14-16 AWG
  • Stud size: 6 stud configuration
  • Terminal type: Spring, snap mechanism
  • Termination method: Crimp
  • Insulation status: Insulated
  • Color: Blue
  • Tongue inside opening: 0.140" (3.56mm)

Both identified substitute parts satisfy these core electrical and mechanical parameters. The PV14-6LF-M maintains identical Panduit Pan-Term® series specifications with active product status. The TE Connectivity 52955-1 provides functional equivalence through the Plasti-Grip series with active availability. Dimensional variations in overall length and insulation diameter remain within acceptable tolerance ranges for the specified stud and wire gauge configuration.

Parameter Comparison

Parameter PV14-6SLF-M (Main) PV14-6LF-M (Substitute) 52955-1 (Substitute)
Manufacturer Panduit Corp Panduit Corp TE Connectivity AMP Connectors
Wire Gauge 14-16 AWG 14-16 AWG 14-16 AWG
Stud/Tab Size 6 Stud 6 Stud 6 Stud
Terminal Type Spring, Snap Spring, Snap Spring, Snap
Termination Crimp Crimp Crimp
Insulation Insulated Insulated Insulated
Color Blue Blue Blue
Contact Material Copper Copper Brass
Contact Finish Tin Tin Tin
Width - Outer Edges 0.250" (6.35mm) 0.250" (6.35mm) 0.250" (6.35mm)
Length - Overall 0.800" (20.32mm) 0.900" (22.86mm) 0.811" (20.60mm)
Mounting Type Free Hanging (In-Line) Free Hanging (In-Line) Free Hanging (In-Line)
Tongue Inside Opening 0.140" (3.56mm) 0.140" (3.56mm) 0.140" (3.56mm)
Product Status Obsolete Active Active
RoHS Status Not applicable ROHS3 Compliant ROHS3 Compliant

Engineering Selection Recommendations

PV14-6LF-M (Panduit Corp): This substitute maintains series continuity within the Pan-Term® product line and is the primary equivalent for the obsolete PV14-6SLF-M. The part is active with ROHS3 compliance and bulk packaging availability. The 0.100" increase in overall length and addition of brazed seam construction represent minor design enhancements. This selection is appropriate for direct replacement in applications where Panduit component standardization is maintained.

52955-1 (TE Connectivity AMP Connectors): This substitute provides functional equivalence through the Plasti-Grip series with active product status and ROHS3 compliance. The contact material differs (brass versus copper), and insulation diameter range is broader (0.118" to 0.193" versus fixed specifications). Overall length of 0.811" closely matches the original PV14-6SLF-M specification. This selection is appropriate for applications where multi-source component qualification is required or where TE Connectivity standardization is established.

Both substitutes satisfy the critical electrical and mechanical parameters. Selection between them depends on existing supply chain qualification, packaging requirements, and manufacturer standardization policies.

Frequently Asked Questions (FAQ)

Q: Can the PV14-6LF-M directly replace the PV14-6SLF-M in existing assemblies?

A: Yes. Both parts share identical wire gauge (14-16 AWG), stud size (6), terminal type (spring snap), termination method (crimp), insulation status, color, and tongue opening (0.140"). The PV14-6LF-M is the active Panduit equivalent with ROHS3 compliance.

Q: What is the significance of the 0.100" length difference between PV14-6SLF-M and PV14-6LF-M?

A: The PV14-6LF-M overall length is 0.900" compared to the original 0.800". This dimensional change reflects design evolution within the Pan-Term® series. Compatibility is maintained for the specified 6 stud configuration and wire gauge range.

Q: Why does the 52955-1 have a brass contact instead of copper?

A: The 52955-1 is manufactured by TE Connectivity using brass contacts within the Plasti-Grip series. Both copper and brass contacts with tin plating provide suitable electrical conductivity for 14-16 AWG crimp termination applications. Contact material selection depends on application-specific requirements and existing qualification standards.

Q: Are there packaging differences between the substitutes?

A: Yes. The PV14-6LF-M is supplied in bulk packaging, while the 52955-1 is supplied in cut tape (CT) packaging. Packaging selection depends on assembly process requirements and inventory management practices.

Q: Do both substitutes meet current compliance standards?

A: Yes. Both PV14-6LF-M and 52955-1 are ROHS3 compliant and carry active product status. The original PV14-6SLF-M is obsolete with not applicable RoHS status. Both substitutes are suitable for applications requiring current regulatory compliance.

Q: Is the insulation diameter variation in the 52955-1 a compatibility concern?

A: The 52955-1 specifies insulation diameter range of 0.118" to 0.193" (3.00mm to 4.90mm), accommodating the 14-16 AWG wire gauge specification. The original PV14-6SLF-M specifies 0.175" (4.45mm), which falls within this range. Compatibility is maintained for the specified wire gauge.

Q: What is the significance of the brazed seam feature in the PV14-6LF-M?

A: The brazed seam construction in the PV14-6LF-M represents a design enhancement in the Pan-Term® series evolution. This feature provides improved structural integrity while maintaining all critical electrical and mechanical parameters for 14-16 AWG crimp termination.

Request Quote (Ships tomorrow)