PSS3-5-12 Equivalent & Substitute Parts Reference

Part Overview

The TDK-Lambda Americas Inc PSS3-5-12 is an Isolated Module DC-DC Converter with a single output of 12V at 250mA, supporting an input voltage range of 4.5V to 9V and maximum power output of 3W. It is packaged in a 6-DIP Module and designed for ITE (Commercial) applications with features such as Remote On/Off and OCP. The product is classified as obsolete, making the identification of substitute models with matching electrical and mechanical parameters an engineering necessity for continuity in design and maintenance.

Substiute Parts

PSS3-5-12
TDK-Lambda Americas IncIn Stock: 1236PSS3-5-12 Datasheet
PSS3-5-12
Current Part
CC3-0512SF-E
TDK-Lambda Americas IncIn Stock: 804CC3-0512SF-E Datasheet
CC3-0512SF-E
Direct

Key Parameters

Manufacturer Part Number Manufacturer Description Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Operating Temperature Mounting Type Package / Case Size / Dimension Product Status Moisture Sensitivity Level (MSL) ECCN HTSUS
PSS3-5-12 TDK-Lambda Americas Inc DC DC CONVERTER 12V 3W Isolated Module 1 4.5V 9V 12V 250mA 3 W ITE (Commercial) -40°C ~ 85°C (With Derating) Through Hole 6-DIP Module 1.02" L x 0.63" W x 0.31" H (25.9mm x 16.0mm x 8.0mm) Obsolete 1 (Unlimited) EAR99 8504.40.9580

Substitute Part Grouping Explanation

Substitute models for the PSS3-5-12 are identified strictly based on matching the following electrical and mechanical parameters: input voltage range (4.5V - 9V), output voltage/functionality (12V, or compatible adjustable 12 ~ 15V), output current (250mA), power rating (3W), number of outputs (1), mounting type (Through Hole), package type (DIP Module), applications (ITE Commercial), and operating temperature range (-40°C ~ 85°C). Only substitute parts provided within these boundaries are considered equivalent.

Parameter Comparison

Manufacturer Part Number Manufacturer Description Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Applications Operating Temperature Mounting Type Package / Case Size / Dimension Product Status Moisture Sensitivity Level (MSL) ECCN HTSUS
PSS3-5-12 TDK-Lambda Americas Inc DC DC CONVERTER 12V 3W Isolated Module 1 4.5V 9V 12V 250mA 3 W ITE (Commercial) -40°C ~ 85°C (With Derating) Through Hole 6-DIP Module 1.02" L x 0.63" W x 0.31" H (25.9mm x 16.0mm x 8.0mm) Obsolete 1 (Unlimited) EAR99 8504.40.9580
CC3-0512SF-E TDK-Lambda Americas Inc DC DC CONVERTER 12-15V 3W Isolated Module 1 4.5V 9V 12 ~ 15V 250mA 3 W ITE (Commercial) -40°C ~ 85°C Through Hole 7-DIP Module 0.90" L x 0.65" W x 0.34" H (22.9mm x 16.6mm x 8.5mm) Active Not Applicable EAR99 8504.40.9580

Engineering Selection Recommendations

The PSS3-5-12 Isolated Module DC DC Converter is obsolete. Substitute part CC3-0512SF-E is an active model with comparable key electrical and mechanical specifications. Both PSS3-5-12 and CC3-0512SF-E are RoHS compliant and classified under ECCN EAR99 and HTSUS 8504.40.9580. These parameters align with regulatory and compliance requirements included in the input.

Frequently Asked Questions (FAQ)

Q1: What parameters must match for a valid DC-DC converter substitution?
A1: Input voltage range, output voltage, output current, power rating, number of outputs, mounting type, package/case, and operating temperature range must match for a substitution to be valid.

Q2: How does package type affect compatibility?
A2: Both main and substitute parts are DIP modules with through hole mounting. Ensure footprint and pin configuration alignment before direct replacement.

Q3: Is there a difference in output voltage specifications between PSS3-5-12 and CC3-0512SF-E?
A3: PSS3-5-12 provides a fixed 12V output. CC3-0512SF-E specifies an output range of 12 ~ 15V. Select according to specific output voltage requirements.

Q4: Does operating temperature range differ?
A4: Both parts support -40°C to 85°C operation, meeting industrial and commercial thermal performance requirements as specified.

Q5: Are there differences in compliance or regulatory status?
A5: Both models are classified as EAR99 and listed under the same HTSUS code. The CC3-0512SF-E also meets RoHS compliance.

Q6: What is the impact of product status on sourcing?
A6: PSS3-5-12 is obsolete. Substitute CC3-0512SF-E is active and suitable for ongoing or new design-in based on provided parameters.