Request Quote
(Ships tomorrow)
PS710CL2-1A-A Equivalent & Substitute Parts
Part Overview
The PS710CL2-1A-A is a solid-state relay (SSR) manufactured by CEL, configured as a SPST-NO (Single Pole Single Throw - Normally Open) switching device. This component provides 2A load switching capability across a 0V to 60V DC/AC output range with a 1.2VDC control input. The PS710CL2-1A-A is classified as obsolete, requiring identification of functionally compatible alternatives for new designs and production continuity.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | PS710CL2-1A-A |
| Manufacturer | CEL |
| Circuit Type | SPST-NO (1 Form A) |
| Output Type | AC, DC |
| Voltage - Input | 1.2VDC |
| Voltage - Load | 0 V ~ 60 V |
| Load Current | 2 A |
| On-State Resistance (Max) | 150 mOhms |
| Mounting Type | Surface Mount |
| Termination Style | Gull Wing |
| Package / Case | 6-SMD (0.300", 7.62mm), 4 Leads |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
The AQY272A from Panasonic Electric Works qualifies as a substitute for the PS710CL2-1A-A based on the following substitution criteria:
Critical Parameters (Must Match):
- Circuit configuration: SPST-NO (1 Form A)
- Output capability: AC and DC switching
- Load current rating: 2 A
- Load voltage range: 0 V ~ 60 V
- Mounting type: Surface Mount
- Termination style: Gull Wing
Compatible Deviations (Within Electrical Tolerance):
- Input voltage: 1.16VDC (substitute) vs. 1.2VDC (original) — operationally compatible
- On-state resistance: 180 mOhms (substitute) vs. 150 mOhms (original) — within acceptable switching performance
- Package footprint: 4-SMD (substitute) vs. 6-SMD (original) — functionally equivalent, potentially board-space favorable
Parameter Comparison
| Parameter | PS710CL2-1A-A (Original) | AQY272A (Substitute) |
|---|---|---|
| Manufacturer | CEL | Panasonic Electric Works |
| Manufacturer Part Number | PS710CL2-1A-A | AQY272A |
| Series | PS, OCMOS | PhotoMOS™ AQY |
| Circuit Type | SPST-NO (1 Form A) | SPST-NO (1 Form A) |
| Output Type | AC, DC | AC, DC |
| Voltage - Input | 1.2VDC | 1.16VDC |
| Voltage - Load | 0 V ~ 60 V | 0 V ~ 60 V |
| Load Current | 2 A | 2 A |
| On-State Resistance (Max) | 150 mOhms | 180 mOhms |
| Mounting Type | Surface Mount | Surface Mount |
| Termination Style | Gull Wing | Gull Wing |
| Package / Case | 6-SMD (0.300", 7.62mm), 4 Leads | 4-SMD (0.300", 7.62mm) |
| Product Status | Obsolete | Active |
| RoHS Status | Not specified | ROHS3 Compliant |
| REACH Status | REACH Affected | REACH Unaffected |
Engineering Selection Recommendations
The AQY272A is the primary substitute for the obsolete PS710CL2-1A-A due to product lifecycle considerations. The original PS710CL2-1A-A has reached end-of-life status, and the AQY272A provides equivalent functional performance across all critical switching parameters.
Regulatory Compliance Advantage: The AQY272A offers improved compliance posture with ROHS3 certification and REACH Unaffected status, whereas the PS710CL2-1A-A carries REACH Affected classification. For applications requiring updated regulatory compliance documentation, the AQY272A is the appropriate selection.
Availability and Supply Chain: The AQY272A is designated as active product status, ensuring continued availability and supplier support. The PS710CL2-1A-A, despite current inventory (831 Pcs), is obsolete and subject to discontinuation.
Electrical Performance: The AQY272A operates at a marginally lower input voltage (1.16VDC vs. 1.2VDC) and exhibits slightly higher on-state resistance (180 mOhms vs. 150 mOhms). These differences remain within acceptable operating parameters for SPST-NO 2A relay applications.
Frequently Asked Questions (FAQ)
Q: Can the AQY272A be used directly in place of the PS710CL2-1A-A without board layout modifications?
A: The AQY272A has a 4-SMD footprint compared to the PS710CL2-1A-A's 6-SMD footprint. PCB pad layouts must be verified for compatibility. Both components use identical termination style (Gull Wing) and identical lead spacing (0.300", 7.62mm), but footprint area differs. Board-level redesign may be required.
Q: What is the impact of the on-state resistance difference (150 mOhms vs. 180 mOhms) on circuit operation?
A: The 30 mOhms difference results in increased voltage drop across the relay during conduction. For a 2A load, this represents an additional 60 mV drop (0.030 Ω × 2 A). System power budgets and thermal management must account for this increased on-state losses.
Q: Are the input control voltage specifications compatible?
A: Yes. The AQY272A operates at 1.16VDC input, compared to the PS710CL2-1A-A at 1.2VDC. This 40 mV difference is operationally compatible with standard microcontroller and signal conditioning circuits. Standard 3.3V and 5V logic signaling remains compatible.
Q: What packaging format is the AQY272A available in?
A: The AQY272A is supplied in Tube packaging. The PS710CL2-1A-A packaging format is not specified in available documentation. Verify packaging requirements for downstream assembly processes.
Q: Does the AQY272A support both AC and DC load switching like the PS710CL2-1A-A?
A: Yes. The AQY272A is rated for both AC and DC output switching across the 0V to 60V load voltage range, identical to the PS710CL2-1A-A specifications.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts