PRG.M0.2GL.LC39G Equivalent & Substitute Parts

Part Overview

The PRG.M0.2GL.LC39G is a 2-position circular connector receptacle manufactured by LEMO, featuring female sockets with solder cup termination and gold-plated contacts. This connector is designed for applications requiring reliable push-pull detent lock fastening in automotive, industrial, medical, and testing equipment environments. The part is currently active in production with 1114 units in stock. Substitute parts are identified to provide alternative sourcing options when the primary part is unavailable or when design flexibility permits component interchange.

Substiute Parts

Key Parameters

Parameter Value
Connector Type Receptacle, Female Sockets
Number of Positions 2
Termination Type Solder Cup
Fastening Type Push-Pull, Detent Lock
Contact Finish Gold
Shell Material Polysulfone (PSU)
Mounting Type Free Hanging (In-Line)
Ingress Protection IP50 - Dust Protected
Cable Opening 0.106" ~ 0.154" (2.70mm ~ 3.90mm)
Current Rating 10A
Operating Temperature -50°C ~ 150°C
RoHS Status ROHS3 Compliant
MSL Rating 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution eligibility for the PRG.M0.2GL.LC39G is determined by strict alignment of the following critical parameters:

  • Connector type: Receptacle with female sockets
  • Position count: 2 positions
  • Termination method: Solder cup
  • Fastening mechanism: Push-pull with detent lock
  • Contact finish: Gold plating
  • Shell material: Polysulfone (PSU)
  • Mounting configuration: Free hanging (in-line)
  • Ingress protection rating: IP50
  • Cable opening range: 0.106" ~ 0.154" (2.70mm ~ 3.90mm)
  • Insert material: Polyetheretherketone (PEEK)
  • Backshell feature: Present
  • Shielding: Unshielded

The identified substitute part K11M07-P02LPH0-3970 (ODU MEDI-SNAP®) meets all critical substitution criteria. Variations in current rating (14A vs. 10A), maximum operating temperature (120°C vs. 150°C), and contact material (brass vs. unspecified) are within acceptable tolerance ranges for component interchange in the specified applications.

Parameter Comparison

Parameter PRG.M0.2GL.LC39G (LEMO) K11M07-P02LPH0-3970 (ODU)
Connector Type Receptacle, Female Sockets Receptacle, Female Sockets
Number of Positions 2 2
Termination Solder Cup Solder Cup
Fastening Type Push-Pull, Detent Lock Push-Pull, Detent Lock
Contact Finish - Mating Gold Gold
Shell Material Polysulfone (PSU) Polysulfone (PSU)
Mounting Type Free Hanging (In-Line) Free Hanging (In-Line)
Ingress Protection IP50 - Dust Protected IP50 - Dust Protected
Cable Opening 0.106" ~ 0.154" (2.70mm ~ 3.90mm) 0.106" ~ 0.154" (2.70mm ~ 3.90mm)
Current Rating (Amps) 10A 14A
Operating Temperature -50°C ~ 150°C -50°C ~ 120°C
Insert Material Polyetheretherketone (PEEK) Polyetheretherketone (PEEK)
Backshell Present Present
Shielding Unshielded Unshielded
RoHS Status ROHS3 Compliant ROHS3 Compliant
MSL Rating 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99

Engineering Selection Recommendations

Both the PRG.M0.2GL.LC39G and K11M07-P02LPH0-3970 are active production parts with ROHS3 compliance and REACH unaffected status, meeting current regulatory requirements for industrial, medical, and automotive applications. The substitute part carries a higher current rating (14A) and supports a narrower maximum operating temperature range (120°C vs. 150°C). Selection between these parts should be based on application-specific thermal and current requirements. Both parts maintain identical mechanical and electrical interface specifications, enabling direct substitution in designs where the operating temperature does not exceed 120°C and current demand does not exceed 10A.

Frequently Asked Questions (FAQ)

Q: Can K11M07-P02LPH0-3970 be used as a direct replacement for PRG.M0.2GL.LC39G?

A: Yes, provided the application operates within the temperature range of -50°C to 120°C and current requirements do not exceed 10A. Both connectors share identical mechanical interfaces, fastening mechanisms, and electrical contact specifications.

Q: What are the key differences between these two parts?

A: The primary differences are the maximum operating temperature (150°C for LEMO vs. 120°C for ODU) and current rating (10A for LEMO vs. 14A for ODU). The ODU part supports higher current capacity but operates within a narrower thermal envelope.

Q: Are both parts suitable for medical applications?

A: Yes. Both the PRG.M0.2GL.LC39G and K11M07-P02LPH0-3970 are listed for medical applications and maintain ROHS3 compliance and REACH unaffected status.

Q: What is the cable opening specification, and does it differ between parts?

A: Both parts support identical cable opening ranges of 0.106" to 0.154" (2.70mm to 3.90mm), ensuring compatibility with the same cable assemblies.

Q: Are these connectors shielded?

A: No. Both the PRG.M0.2GL.LC39G and K11M07-P02LPH0-3970 are unshielded connectors. If electromagnetic shielding is required, alternative connector designs must be evaluated.

Q: What termination method do these connectors use?

A: Both connectors use solder cup termination, requiring direct soldering to PCB pads or wire leads. No crimping or other termination methods are applicable.

Q: Do these parts require special handling or storage conditions?

A: Both parts carry MSL Rating 1 (Unlimited), indicating no moisture sensitivity restrictions during storage or handling.