Request Quote
(Ships tomorrow)
PRD-3AG0-24 Equivalent & Substitute Parts
Part Overview
The PRD-3AG0-24 is a general purpose relay manufactured by TE Connectivity Potter & Brumfield Relays. This SPST-NO (Single Pole Single Throw - Normally Open) relay is rated for 30A at 24VAC coil voltage with chassis mount configuration and screw terminal termination. The part is classified as obsolete, making identification of equivalent substitute components necessary for ongoing system maintenance and new design implementations where this relay specification is required.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | PRD-3AG0-24 |
| Manufacturer | TE Connectivity Potter & Brumfield Relays |
| Contact Form | SPST-NO (DM) (1 Form X) |
| Coil Voltage | 24VAC |
| Contact Rating (Current) | 30 A |
| Switching Voltage | 277VAC - Nom |
| Mounting Type | Chassis Mount |
| Termination Style | Screw Terminal |
| Coil Type | Non Latching |
| Product Status | Obsolete |
| RoHS Status | ROHS3 Compliant |
Substitute Part Grouping Explanation
Substitute parts for the PRD-3AG0-24 are identified based on strict electrical and mechanical parameter matching. The following criteria determine substitution eligibility:
Critical Matching Parameters:
- Contact form configuration: SPST-NO (1 Form X)
- Coil voltage: 24VAC
- Contact current rating: 30 A minimum
- Mounting type: Chassis Mount
- Termination style: Screw Terminal
- Coil type: Non Latching
Operational Compatibility Parameters:
- Must operate voltage: 20.4 VAC or lower
- Coil resistance within acceptable tolerance range
- Operating temperature range that encompasses or exceeds -55°C to 45°C
- Compliance certifications: RoHS and ECCN EAR99
The MGN1X-AC24 from Omron Automation and Safety meets all critical matching parameters and operational compatibility requirements, qualifying it as a direct substitute for the obsolete PRD-3AG0-24.
Parameter Comparison
| Parameter | PRD-3AG0-24 (Main Part) | MGN1X-AC24 (Substitute) |
|---|---|---|
| Manufacturer | TE Connectivity Potter & Brumfield Relays | Omron Automation and Safety |
| Contact Form | SPST-NO (DM) (1 Form X) | SPST-NO (DM) (1 Form X) |
| Coil Voltage | 24VAC | 24VAC |
| Contact Rating (Current) | 30 A | 30 A |
| Switching Voltage | 277VAC - Nom | 600VAC, 28VDC - Max |
| Coil Current | 410 mA | 396 mA |
| Coil Resistance | 12 Ohms | 11.5 Ohms |
| Mounting Type | Chassis Mount | Chassis Mount |
| Termination Style | Screw Terminal | Screw Terminal |
| Coil Type | Non Latching | Non Latching |
| Must Operate Voltage | 20.4 VAC | 20.4 VAC |
| Operate Time | 40 ms | 30 ms |
| Release Time | 20 ms | 30 ms |
| Operating Temperature | -55°C ~ 45°C | -45°C ~ 80°C |
| Coil Insulation | Class B | Class F |
| Product Status | Obsolete | Active |
| RoHS Status | ROHS3 Compliant | RoHS Compliant |
| MSL Rating | 1 (Unlimited) | 1 (Unlimited) |
| ECCN | EAR99 | EAR99 |
Engineering Selection Recommendations
The MGN1X-AC24 is the qualified substitute for the obsolete PRD-3AG0-24 based on the following engineering criteria:
Functional Equivalence: Both relays share identical contact form configuration (SPST-NO), coil voltage (24VAC), current rating (30A), mounting type (Chassis Mount), and termination style (Screw Terminal). Coil resistance values are within 4% tolerance (12 Ohms vs. 11.5 Ohms), ensuring compatible circuit behavior.
Compliance Status: The MGN1X-AC24 maintains active product status with current RoHS compliance certification and EAR99 ECCN classification, matching the regulatory framework of the original part. Both components carry MSL Level 1 (Unlimited) moisture sensitivity rating.
Operational Performance: The MGN1X-AC24 demonstrates superior switching voltage capability (600VAC maximum vs. 277VAC nominal) and extended operating temperature range (-45°C to 80°C vs. -55°C to 45°C). Operate time is improved at 30 ms versus 40 ms. Coil current draw is slightly lower at 396 mA compared to 410 mA, reducing power consumption.
Thermal Characteristics: The substitute part features Class F coil insulation compared to Class B in the original, providing enhanced thermal stability for extended operational life.
Frequently Asked Questions (FAQ)
Q: Can the MGN1X-AC24 directly replace the PRD-3AG0-24 in existing applications?
A: Yes. Both relays meet identical specifications for contact form, coil voltage, current rating, mounting configuration, and termination style. The MGN1X-AC24 is electrically and mechanically compatible for direct substitution in chassis-mounted 24VAC SPST-NO relay applications rated for 30A.
Q: What are the key differences between these two relays?
A: The primary differences are: (1) Switching voltage capability—MGN1X-AC24 supports 600VAC maximum versus 277VAC nominal for PRD-3AG0-24; (2) Operating temperature range—MGN1X-AC24 extends to 80°C versus 45°C maximum; (3) Coil insulation class—MGN1X-AC24 uses Class F versus Class B; (4) Timing characteristics—MGN1X-AC24 operates faster at 30 ms versus 40 ms. These differences represent performance enhancements in the substitute part.
Q: Are there any compatibility concerns with screw terminal connections?
A: No. Both relays use identical screw terminal termination style, ensuring direct mechanical and electrical compatibility without connector modifications.
Q: Does the MGN1X-AC24 meet the same regulatory requirements?
A: Yes. The MGN1X-AC24 is RoHS compliant and carries EAR99 ECCN classification, matching the regulatory compliance profile of the PRD-3AG0-24. Both components have MSL Level 1 (Unlimited) moisture sensitivity rating.
Q: What is the coil current difference between these relays?
A: The MGN1X-AC24 draws 396 mA compared to 410 mA for the PRD-3AG0-24. This 14 mA reduction (3.4% lower) results in decreased power consumption and reduced heat generation in the coil circuit.
Q: Can the MGN1X-AC24 operate in the full temperature range of the original part?
A: The MGN1X-AC24 operates from -45°C to 80°C, which covers the original part's range of -55°C to 45°C except for the lower extreme of -55°C. For applications requiring operation below -45°C, the original PRD-3AG0-24 specification must be maintained.
Q: Is the MGN1X-AC24 currently available?
A: Yes. The MGN1X-AC24 is classified as an active product with current manufacturing status, ensuring ongoing availability and supply chain reliability compared to the obsolete PRD-3AG0-24.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts