PM-Y44P-C3 Equivalent & Substitute Parts

Part Overview

The PM-Y44P-C3 is an optical sensor module manufactured by Panasonic Industrial Automation Sales, designed for through-beam sensing applications with a 0.197" (5mm) sensing distance. This slot-type sensor features PNP output with selectable Dark-ON/Light-ON functionality, wire leads, and chassis mount configuration. The product is currently obsolete, making identification of compatible substitute parts essential for system maintenance and component sourcing.

Substiute Parts

PM-Y44P-C3
Panasonic Industrial Automation SalesIn Stock: 834PM-Y44P-C3 Datasheet
PM-Y44P-C3
Current Part
PM-Y45-P-C3
Panasonic Industrial Automation SalesIn Stock: 1189PM-Y45-P-C3 Datasheet
PM-Y45-P-C3
Similar

Key Parameters

Parameter Value
Manufacturer Part Number PM-Y44P-C3
Manufacturer Panasonic Industrial Automation Sales
Category Optical Sensors
Sensing Method Through-Beam
Sensing Distance 0.197" (5mm)
Output Configuration PNP - Dark-ON/Light-ON - Selectable
Current - DC Forward (Max) 50 mA
Current - Collector (Max) 15 mA
Voltage - Collector Emitter Breakdown (Max) 30 V
Response Time 20µs
Mounting Type Chassis Mount
Package / Case Module, Wire Leads, Slot Type
Type Unamplified
RoHS Status RoHS Compliant
Product Status Obsolete

Substitute Part Grouping Explanation

Substitution of the PM-Y44P-C3 is determined by the following critical parameters:

  • Sensing Method: Through-beam optical sensing capability
  • Output Configuration: PNP output type
  • Mounting Type: Chassis mount with wire leads
  • Response Time: 20µs performance specification
  • Regulatory Compliance: RoHS compliance status

The PM-Y45-P-C3 qualifies as a substitute based on matching sensing method (through-beam), output type (PNP), mounting configuration (chassis mount with wire leads), and response time capability (20µs available). While the sensing distance differs (0.236" versus 0.197"), both operate within the through-beam optical sensor category with compatible electrical and mechanical interfaces.

Parameter Comparison

Parameter PM-Y44P-C3 (Main) PM-Y45-P-C3 (Substitute)
Manufacturer Panasonic Industrial Automation Sales Panasonic Industrial Automation Sales
Category Optical Sensors Optical Sensors
Sensing Method Through-Beam Through-Beam
Sensing Distance 0.197" (5mm) 0.236" (6mm)
Output Configuration PNP - Dark-ON/Light-ON - Selectable PNP - Open Collector
Current - Collector (Max) 15 mA 15 mA
Response Time 20µs 20µs, 80µs
Mounting Type Chassis Mount Chassis Mount
Package / Case Module, Wire Leads, Slot Type Module, Wire Leads
RoHS Status RoHS Compliant ROHS3 Compliant
Product Status Obsolete Active

Engineering Selection Recommendations

The PM-Y45-P-C3 is the designated substitute for the obsolete PM-Y44P-C3. Selection of this substitute is supported by:

  • Product Status: The PM-Y45-P-C3 maintains active product status, ensuring continued availability and supply chain reliability
  • Regulatory Compliance: Both parts meet RoHS requirements; the substitute achieves ROHS3 compliance, meeting current environmental standards
  • Electrical Compatibility: Matching collector current specification (15 mA maximum) and response time capability (20µs) ensure functional equivalence in through-beam sensing applications
  • Mechanical Interface: Both parts feature chassis mount configuration with wire leads, supporting direct integration into existing mechanical assemblies

The primary design consideration is the increased sensing distance of the PM-Y45-P-C3 (0.236" versus 0.197"), which may require validation in applications with tight spatial constraints or specific gap requirements.

Frequently Asked Questions (FAQ)

Q: Can the PM-Y45-P-C3 directly replace the PM-Y44P-C3 in all applications?

A: The PM-Y45-P-C3 is electrically and mechanically compatible as a substitute. However, the increased sensing distance (6mm versus 5mm) must be evaluated for your specific application geometry. If your system requires the exact 5mm sensing distance, physical validation is necessary.

Q: What is the difference between Dark-ON/Light-ON selectable and Open Collector output?

A: The PM-Y44P-C3 offers selectable output logic (Dark-ON or Light-ON), while the PM-Y45-P-C3 provides PNP Open Collector output. Both are PNP configurations; the substitute does not include the selectable logic feature. Verify your application's output logic requirement before substitution.

Q: Are there packaging differences between these parts?

A: Both parts use module packaging with wire leads and chassis mount configuration. The PM-Y44P-C3 specifies slot-type packaging, while the PM-Y45-P-C3 uses standard module packaging. Physical form factor should be verified against your mechanical assembly requirements.

Q: Why is the PM-Y44P-C3 listed as obsolete?

A: The PM-Y44P-C3 has reached end-of-life status. The PM-Y45-P-C3 represents the active product line continuation from Panasonic Industrial Automation Sales for through-beam optical sensing in this category.

Q: Do both parts meet current environmental compliance standards?

A: Yes. The PM-Y44P-C3 is RoHS Compliant, and the PM-Y45-P-C3 achieves ROHS3 Compliant status, meeting current regulatory requirements for electronic components.

Request Quote (Ships tomorrow)