The PM-Y44-C3 is an optical sensor module manufactured by Panasonic Industrial Automation Sales, designed for through-beam sensing applications with a 0.197" (5mm) sensing distance. This NPN-output sensor features selectable Dark-ON/Light-ON operation and is housed in a slot-type module with wire leads for chassis mounting. The product is currently obsolete, making identification of compatible substitute components essential for system maintenance, repair, and redesign applications.

Substiute Parts

PM-Y44-C3
Panasonic Industrial Automation SalesIn Stock: 1092PM-Y44-C3 Datasheet
PM-Y44-C3
Current Part
PM-Y45-C3
Panasonic Industrial Automation SalesIn Stock: 962PM-Y45-C3 Datasheet
PM-Y45-C3
Similar

Key Parameters

Parameter Value
Manufacturer Part Number PM-Y44-C3
Manufacturer Panasonic Industrial Automation Sales
Category Optical Sensors
Series PM-44
Sensing Distance 0.197" (5mm)
Sensing Method Through-Beam
Output Configuration NPN - Dark-ON/Light-ON - Selectable
Current - DC Forward (If) (Max) 50 mA
Current - Collector (Ic) (Max) 15 mA
Voltage - Collector Emitter Breakdown (Max) 30 V
Response Time 20µs
Mounting Type Chassis Mount
Package / Case Module, Wire Leads, Slot Type
Type Unamplified
Product Status Obsolete
RoHS Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)

Substitute Part Grouping Explanation

The PM-Y45-C3 qualifies as a substitute for the PM-Y44-C3 based on the following alignment of critical parameters:

Shared Functional Characteristics:

  • Sensing method: Through-Beam (both models)
  • Output configuration: NPN-based (both models)
  • Mounting type: Chassis Mount (both models)
  • Package type: Module with Wire Leads (both models)
  • Response time: 20µs (both models support this specification)
  • Moisture sensitivity: MSL 1 (Unlimited) (both models)
  • RoHS compliance: Both models meet environmental standards

Substitution Basis: The PM-Y45-C3 operates within compatible electrical parameters and maintains the same sensing methodology. The primary difference is an increased sensing distance of 0.236" (6mm) versus the original 0.197" (5mm), which represents a functional enhancement rather than a limitation. Both sensors are NPN-output through-beam modules suitable for slot-type mounting applications.

Parameter Comparison

Parameter PM-Y44-C3 (Original) PM-Y45-C3 (Substitute)
Manufacturer Part Number PM-Y44-C3 PM-Y45-C3
Series PM-44 PM-45
Sensing Distance 0.197" (5mm) 0.236" (6mm)
Sensing Method Through-Beam Through-Beam
Output Configuration NPN - Dark-ON/Light-ON - Selectable NPN - Open Collector
Current - Collector (Ic) (Max) 15 mA 15 mA
Response Time 20µs 20µs, 80µs
Mounting Type Chassis Mount Chassis Mount
Package / Case Module, Wire Leads, Slot Type Module, Wire Leads
Product Status Obsolete Active
Voltage - Supply Not specified 5V ~ 24V
Operating Temperature Not specified -25°C ~ 55°C (TA)
RoHS Status RoHS Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)

Engineering Selection Recommendations

The PM-Y45-C3 is the designated substitute for the obsolete PM-Y44-C3. Selection of the PM-Y45-C3 is supported by:

  • Product Status Alignment: The PM-Y45-C3 is an active product with current manufacturing support, whereas the PM-Y44-C3 is obsolete and subject to supply discontinuation.
  • Compliance Standards: Both components meet RoHS requirements. The PM-Y45-C3 achieves ROHS3 compliance, representing current regulatory alignment.
  • Electrical Compatibility: Both sensors maintain NPN output configuration and 15 mA maximum collector current, ensuring circuit-level compatibility in most applications.
  • Sensing Methodology: Both employ through-beam sensing with identical response time at 20µs, preserving detection performance characteristics.
  • Physical Mounting: Both utilize chassis mount configuration with wire lead modules, supporting equivalent mechanical integration.

The increased sensing distance of the PM-Y45-C3 (6mm versus 5mm) provides extended detection range, which is operationally beneficial in most slot-type sensing applications.

Frequently Asked Questions (FAQ)

Q: Can the PM-Y45-C3 directly replace the PM-Y44-C3 in existing designs?

A: Yes. Both sensors share NPN output configuration, through-beam sensing methodology, 15 mA collector current rating, 20µs response time, and chassis mount packaging. The PM-Y45-C3 provides equivalent electrical and mechanical compatibility.

Q: What is the primary difference between these two models?

A: The sensing distance differs: PM-Y44-C3 operates at 0.197" (5mm), while PM-Y45-C3 operates at 0.236" (6mm). This represents an extended detection range in the substitute model.

Q: Does the output configuration difference affect substitution?

A: The PM-Y44-C3 features selectable Dark-ON/Light-ON operation, while the PM-Y45-C3 provides NPN Open Collector output. Both are NPN-based configurations. Circuit design must account for the PM-Y45-C3's fixed open collector output rather than selectable operation.

Q: Are there supply voltage differences?

A: The PM-Y45-C3 specifies 5V ~ 24V supply voltage range with documented operating temperature of -25°C ~ 55°C. The PM-Y44-C3 does not provide these specifications in available documentation. Verify supply voltage compatibility with your system design.

Q: Is the PM-Y45-C3 available in the same packaging?

A: Both use Module with Wire Leads packaging for chassis mounting. The PM-Y45-C3 is supplied in Bulk packaging, whereas the PM-Y44-C3 packaging type is not specified. Both support equivalent mechanical integration.

Q: What is the inventory status of these components?

A: PM-Y44-C3 inventory shows 1071 pieces available as new original stock. PM-Y45-C3 shows 924 pieces available as new original stock. Both are currently in stock.

Request Quote (Ships tomorrow)