Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts Reference: PEM1-S12-S12-S
Part Overview
Manufacturer Part Number: PEM1-S12-S12-S is an isolated module DC DC converter with a single 12V output at a maximum current of 83mA, operating within a 10.8V to 13.2V input range, and supporting up to 1W output power. This product is part of the PEM1-S (1W) series from CUI Inc. With an active product status and significant inventory, users may require alternatives due to supply chain management, multi-sourcing requirements, or compliance considerations within the isolated DC DC converter product category.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Type | Isolated Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 10.8V |
| Voltage - Input (Max) | 13.2V |
| Voltage - Output 1 | 12V |
| Current - Output (Max) | 83mA |
| Power (Watts) | 1 W |
| Voltage - Isolation | 3 kV |
| Operating Temperature | -40°C ~ 105°C |
| Efficiency | 80% |
| Mounting Type | Through Hole |
| Package / Case | 7-SIP Module, 4 Leads |
| Size / Dimension | 0.77" L x 0.24" W x 0.37" H (19.5mm x 6.0mm x 9.3mm) |
| RoHS Status | RoHS Compliant |
| MSL | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution logic is determined strictly by the following allowed parameters: type (isolated module), number of outputs (1), input voltage range (10.8V–13.2V), output voltage (12V), output current (≥83mA), output power (≈1 W), voltage isolation (≥3 kV), mounting type (through hole), package/case format (7-SIP Module, 4 Leads), and regulatory compliance status. Only components matching these key engineering parameters qualify as substitutes within the isolated DC DC converter category.
Parameter Comparison
| Parameter | PEM1-S12-S12-S | PEME1-S12-S12-S | RP-1212S |
|---|---|---|---|
| Manufacturer | CUI Inc. | CUI Inc. | Recom Power |
| Type | Isolated Module | Isolated Module | Isolated Module |
| Number of Outputs | 1 | 1 | 1 |
| Voltage - Input (Min) | 10.8V | 10.8V | 10.8V |
| Voltage - Input (Max) | 13.2V | 13.2V | 13.2V |
| Voltage - Output 1 | 12V | 12V | 12V |
| Current - Output (Max) | 83mA | 83mA | 84mA |
| Power (Watts) | 1 W | 996 mW | 1 W |
| Voltage - Isolation | 3 kV | 3 kV | 5.2 kV |
| Operating Temperature | -40°C ~ 105°C | -40°C ~ 105°C (With Derating) | -40°C ~ 85°C |
| Efficiency | 80% | 80% | 78% |
| Mounting Type | Through Hole | Through Hole | Through Hole |
| Package / Case | 7-SIP Module, 4 Leads | 7-SIP Module, 4 Leads | 7-SIP Module, 4 Leads |
| Size / Dimension | 0.77" L x 0.24" W x 0.37" H | 0.77" L x 0.24" W x 0.40" H | 0.77" L x 0.28" W x 0.40" H |
| RoHS Status | RoHS Compliant | RoHS Compliant | ROHS3 Compliant |
| MSL | 1 (Unlimited) | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
All listed substitute parts have active product status, RoHS compliance, and MSL rating of 1 (Unlimited). Both PEM1-S12-S12-S and PEME1-S12-S12-S provide CB Scheme, EN, IEC, UL, CE, and cURus approval agency coverage, while RP-1212S offers ROHS3 compliance and ITE/Medical application suitability. Certification alignment should be verified against system requirements based on the provided information.
Frequently Asked Questions (FAQ)
What key parameters determine substitute eligibility for PEM1-S12-S12-S?
Substitution is based on matching type (isolated module), number of outputs (1), input voltage range (10.8V–13.2V), output voltage (12V), output current (≥83mA), output power (≈1 W), voltage isolation (≥3 kV), mounting style, package/case, RoHS compliance, and moisture sensitivity rating.
Are there significant mechanical differences between these substitutes?
All parts share the 7-SIP Module, 4 Leads package and through-hole mounting, with slight dimensional variations as specified in the key parameter comparison.
What regulatory certifications are covered by these substitutes?
PEM1-S12-S12-S and PEME1-S12-S12-S have CB Scheme, EN, IEC, UL, CE, cURus approvals; RP-1212S specifies ROHS3 compliance and ITE/Medical suitability. Certification should be selected as required by system-level standards.
Is efficiency a consideration in substitution?
Efficiency ranges from 78% to 80% across models, within typical tolerance for this category, and must align with specification requirements as listed.
Do all substitutes support single output at 12V?
Yes. All listed substitutes provide a single 12V output within the allowed current and power specifications.
Is the voltage isolation specification consistent?
PEM1-S12-S12-S and PEME1-S12-S12-S have 3 kV isolation; RP-1212S offers 5.2 kV. All meet or exceed the main part’s specified value.
Are mounting styles or packaging types consistent?
Yes. All substitutes utilize through-hole mounting and the 7-SIP Module, 4 Leads format per specifications provided.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts