Part Overview

The PDQ2-D48-D12-S from CUI Inc. is an isolated DC-DC converter module featuring dual outputs (+12V, -12V) at 2W total power. Designed for ITE (commercial) applications, it supports a wide input range (36V–75V), 1.5 kV isolation, and key protection features including OCP and SCP. With an active product status and RoHS compliance, it is used for demanding applications requiring dual isolated supply rails. Identifying alternative models ensures continuity in case of lead time constraints, supply interruptions, or multi-sourcing requirements.

Substiute Parts

PDQ2-D48-D12-S
CUI Inc.In Stock: 1184PDQ2-D48-D12-S Datasheet
PDQ2-D48-D12-S
Current Part
DPAN02C-12
MEAN WELL USA Inc.In Stock: 962DPAN02C-12 Datasheet
DPAN02C-12
Similar

Key Parameters

Parameter PDQ2-D48-D12-S
Type Isolated Module
Number of Outputs 2
Voltage - Input (Min) 36V
Voltage - Input (Max) 75V
Voltage - Output 1 12V
Voltage - Output 2 -12V
Current - Output (Max) 83mA, 83mA
Power (Watts) 2 W
Voltage - Isolation 1.5 kV
Applications ITE (Commercial)
Features Remote On/Off, OCP, SCP
Operating Temperature -40°C ~ 100°C
Efficiency 82%
Mounting Type Through Hole
Package / Case 8-SIP Module, 7 Leads
Size / Dimension 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm)
RoHS Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
REACH Status REACH Unaffected
Product Status Active

Substitute Part Grouping Explanation

Substitute parts are identified strictly based on matching the following key functional and compliance parameters provided for isolated DC-DC converter modules:

  • Dual output configuration: 12V and -12V
  • Input voltage range: 36V to 75V
  • Output current: 83mA per channel
  • Power rating: 2W
  • Isolation voltage: 1.5 kV
  • Feature set: Remote On/Off, OCP, SCP
  • Package: 8-SIP Module, 7 Leads, Through Hole
  • RoHS and REACH compliance
  • Applications: ITE (commercial)
  • Operating temperature range within provided limits

Only parts matching these specific criteria are considered substitutes.

Parameter Comparison

Parameter PDQ2-D48-D12-S
(CUI Inc.)
DPAN02C-12
(MEAN WELL USA Inc.)
Type Isolated Module Isolated Module
Number of Outputs 2 2
Voltage - Input (Min) 36V 36V
Voltage - Input (Max) 75V 75V
Voltage - Output 1 12V 12V
Voltage - Output 2 -12V -12V
Current - Output (Max) 83mA, 83mA 83mA, 83mA
Power (Watts) 2 W 2 W
Voltage - Isolation 1.5 kV 1.5 kV
Applications ITE (Commercial) ITE (Commercial)
Features Remote On/Off, OCP, SCP Remote On/Off, OCP, SCP, UVLO
Operating Temperature -40°C ~ 100°C -40°C ~ 90°C (With Derating)
Efficiency 82% 82%
Mounting Type Through Hole Through Hole
Package / Case 8-SIP Module, 7 Leads 8-SIP Module, 7 Leads
Size / Dimension 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.1mm x 11.2mm) 0.86" L x 0.36" W x 0.44" H (21.8mm x 9.2mm x 11.1mm)
RoHS Status RoHS Compliant ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
Product Status Active Active

Engineering Selection Recommendations

Both PDQ2-D48-D12-S (CUI Inc.) and DPAN02C-12 (MEAN WELL USA Inc.) are listed as active products with RoHS and REACH compliance, suitable for lead-free and environmentally-regulated applications. Moisture Sensitivity Level is 1 (Unlimited) for both, supporting standard assembly and storage conditions. Both parts are qualified for ITE (commercial) use and the specified regulatory standard for emissions. Selection is determined by product status, regulatory compliance, and availability.

Frequently Asked Questions (FAQ)

Q: What are the primary criteria for substituting the PDQ2-D48-D12-S DC-DC converter?
A: Substitute models must match input voltage range (36V–75V), dual 12V/-12V output configuration, 83mA output current per rail, 2W total power, 1.5 kV isolation, package type (8-SIP Module, 7 Leads), and regulatory compliance (RoHS, REACH).

Q: Are the package size and pinout considered in these substitutions?
A: Yes, only parts with identical or extremely close physical dimensions and through-hole 8-SIP, 7-lead packages are considered substitutes to ensure mechanical and soldering compatibility.

Q: Does product status affect the suitability of substitutes?
A: Only active products are included as substitutes, ensuring ongoing supply chain reliability and long-term support.

Q: Are there differences in compliance or features that impact substitution?
A: Both models meet RoHS and REACH requirements. Variations in optional features are limited to parameters provided; for example, both include Remote On/Off, OCP, and SCP.

Q: Can these substitutes operate in the same temperature range?
A: Provided operating temperature ranges are listed for each part; ensure requirements fall within or match the specified ranges to maintain performance.

Q: Are there restrictions on mounting type when substituting?
A: Only through-hole parts of the same package type are considered, ensuring direct fit into existing PCB designs.