Equivalent & Substitute Parts Reference for PDM2-S5-S5-D

Part Overview

The CUI Inc. PDM2-S5-S5-D is an isolated DC DC converter providing a single 5V output at up to 400mA from a 4.5V – 5.5V input, rated for 2W maximum output power with 1.5 kV isolation. This product is classified as obsolete. When a DC DC converter with identical electrical and mechanical specifications is required and the original part is no longer available, substitution with an approved equivalent is necessary to maintain compatibility and compliance in ITE (Commercial) applications.

Substiute Parts

PDM2-S5-S5-D
CUI Inc.In Stock: 951PDM2-S5-S5-D Datasheet
PDM2-S5-S5-D
Current Part
PDME2-S5-S5-D
CUI Inc.In Stock: 984PDME2-S5-S5-D Datasheet
PDME2-S5-S5-D
MFR Recommended
PDME2-S5-S5-S
CUI Inc.In Stock: 1281PDME2-S5-S5-S Datasheet
PDME2-S5-S5-S
MFR Recommended

Key Parameters

Manufacturer Part Number Series Product Status Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension Approval Agency Standard Number RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS
PDM2-S5-S5-D PDM2-D (2W) Obsolete Isolated Module 1 4.5V 5.5V 5V 400mA 2 W 1.5 kV ITE (Commercial) -40°C ~ 105°C (With Derating) 85% Through Hole 14-DIP Module, 6 Leads 0.80" L x 0.40" W x 0.32" H (20.3mm x 10.2mm x 8.2mm) CB Scheme, EN, IEC, UL 55024; 55032 Class A; 60950-1 RoHS Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9580

Substitute Part Grouping Explanation

Substitute parts for the PDM2-S5-S5-D have been identified exclusively based on matching electrical and mechanical parameters. These key parameters for substitution include: operating input voltage range (4.5V – 5.5V), single 5V output at 400mA, 2W maximum output power, 1.5kV isolation voltage, identical application category (ITE Commercial), through-hole mounting, and RoHS/REACH compliance. Certification and standard alignment is included strictly per provided details. Package style and dimensions are noted for reference to ensure mechanical compatibility.

Parameter Comparison

Manufacturer Part Number Series Product Status Type Number of Outputs Voltage - Input (Min) Voltage - Input (Max) Voltage - Output 1 Current - Output (Max) Power (Watts) Voltage - Isolation Applications Operating Temperature Efficiency Mounting Type Package / Case Size / Dimension Approval Agency Standard Number RoHS Status Moisture Sensitivity Level (MSL) REACH Status ECCN HTSUS
PDM2-S5-S5-D PDM2-D (2W) Obsolete Isolated Module 1 4.5V 5.5V 5V 400mA 2 W 1.5 kV ITE (Commercial) -40°C ~ 105°C (With Derating) 85% Through Hole 14-DIP Module, 6 Leads 0.80" L x 0.40" W x 0.32" H (20.3mm x 10.2mm x 8.2mm) CB Scheme, EN, IEC, UL 55024; 55032 Class A; 60950-1 RoHS Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9580
PDME2-S5-S5-D PDME2-S (2W) Active Isolated Module 1 4.5V 5.5V 5V 400mA 2 W 1.5 kV ITE (Commercial) -40°C ~ 105°C (With Derating) 84% Through Hole 7-SIP Module, 4 Leads 0.77" L x 0.28" W x 0.40" H (19.7mm x 7.1mm x 10.2mm) cURus 62368-1 - - - EAR99 8504.40.9580
PDME2-S5-S5-S PDME2-S (2W) Active Isolated Module 1 4.5V 5.5V 5V 400mA 2 W 1.5 kV ITE (Commercial) -40°C ~ 105°C (With Derating) 84% Through Hole 7-SIP Module, 4 Leads 0.77" L x 0.28" W x 0.40" H (19.7mm x 7.1mm x 10.2mm) cURus 62368-1 ROHS3 Compliant 1 (Unlimited) REACH Unaffected EAR99 8504.40.9580

Engineering Selection Recommendations

Substitute selection for the obsolete PDM2-S5-S5-D should be based on the availability of active products with matching electrical ratings, regulatory compliance, and agency approvals as provided. PDME2-S5-S5-D and PDME2-S5-S5-S are active CUI Inc. DC DC converters offering equivalent input range, output voltage and current, isolation rating, mounting type, and certifications per ITE (Commercial) application requirements. RoHS and REACH compliance, as well as regulatory approvals, are indicated per supplied documentation.

Frequently Asked Questions (FAQ)

Q1: What electrical parameters must match when choosing a substitute for PDM2-S5-S5-D?
A1: Input voltage range (4.5V – 5.5V), single output voltage (5V), output current (400mA), output power (2W), and isolation voltage (1.5kV) must match exactly.

Q2: Are the substitute models compatible with the same application category?
A2: All listed substitutes are classified under ITE (Commercial) applications per manufacturer documentation.

Q3: Are there any compliance or regulatory differences between the original and substitute parts?
A3: Substitute parts provide RoHS and REACH compliance, with alternate agency approvals (cURus vs. CB Scheme, EN, IEC, UL) and standard numbers, as specified in the parameter comparison.

Q4: Do replacement parts use the same mounting method?
A4: Substitutes use through-hole mounting. Package type varies between 14-DIP Module, 6 Leads and 7-SIP Module, 4 Leads. Review mechanical fit based exclusively on provided dimensions.

Q5: Does efficiency vary between the original and substitutes?
A5: The original part (PDM2-S5-S5-D) has an efficiency of 85%. Substitute parts (PDME2-S5-S5-D and PDME2-S5-S5-S) specify 84% efficiency.

Q6: Are environmental and moisture sensitivity ratings maintained in substitutes?
A6: All parts specify Moisture Sensitivity Level (MSL) 1 (Unlimited) and REACH Unaffected status.

Request Quote (Ships tomorrow)