Equivalent & Substitute Parts Reference for PDM2-S5-D12-D

Part Overview

The CUI Inc. PDM2-S5-D12-D is an isolated module DC-DC converter designed for ITE (commercial) applications, delivering two 12V outputs at a maximum of 83mA per channel, with 2W total output power. It operates from a 4.5V to 5.5V input, features short-circuit protection, and is housed in a 14-DIP module case. This product is currently marked as "Obsolete," necessitating identification of alternatives for ongoing design, replacement, or inventory purposes.

Substiute Parts

PDM2-S5-D12-D
CUI Inc.In Stock: 1047PDM2-S5-D12-D Datasheet
PDM2-S5-D12-D
Current Part
PDME2-S5-D12-D
CUI Inc.In Stock: 919PDME2-S5-D12-D Datasheet
PDME2-S5-D12-D
MFR Recommended
PDME2-S5-D12-S
CUI Inc.In Stock: 855PDME2-S5-D12-S Datasheet
PDME2-S5-D12-S
MFR Recommended

Key Parameters

Parameter PDM2-S5-D12-D
Manufacturer CUI Inc.
Series PDM2-D (2W)
Product Status Obsolete
Type Isolated Module
Number of Outputs 2
Voltage - Input (Min) 4.5V
Voltage - Input (Max) 5.5V
Voltage - Output 1 12V
Voltage - Output 2 12V
Current - Output (Max) 83mA, 83mA
Power (Watts) 2 W
Voltage - Isolation 1.5 kV
Applications ITE (Commercial)
Operating Temperature -40°C ~ 105°C (With Derating)
Efficiency 84%
Mounting Type Through Hole
Package / Case 14-DIP Module, 6 Leads
Size / Dimension 0.80" L x 0.40" W x 0.32" H
Approval Agency CB Scheme, EN, IEC, UL
Standard Number 55024; 55032 Class A; 60950-1
RoHS Status RoHS Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited)
ECCN EAR99
HTSUS 8504.40.9580

Substitute Part Grouping Explanation

Substitute selection for DC-DC converters is strictly based on matching input voltage range, output voltage(s), output current, power rating, isolation voltage, number of outputs, mounting type, operating temperature range, and application compliance. Packaging, approvals, and environmental compliance are also considered. Only products meeting these explicit criteria are listed as equivalents or substitutes.

Key substitution parameters:

  • Input voltage range
  • Output voltage(s) and configuration
  • Maximum output current
  • Power rating
  • Isolation voltage
  • Number of outputs
  • Mounting and package/case style
  • Operating temperature range
  • Relevant approvals and certifications
  • Environmental compliance

Parameter Comparison

Parameter PDM2-S5-D12-D PDME2-S5-D12-D PDME2-S5-D12-S
Manufacturer CUI Inc. CUI Inc. CUI Inc.
Product Status Obsolete Active Active
Type Isolated Module Isolated Module Isolated Module
Number of Outputs 2 2 2
Voltage - Input (Min) 4.5V 4.5V 4.5V
Voltage - Input (Max) 5.5V 5.5V 5.5V
Voltage - Output 1 12V 12V 12V
Voltage - Output 2 12V -12V -12V
Current - Output (Max) 83mA, 83mA 83mA, 83mA 83mA, 83mA
Power (Watts) 2 W 1.992 W 2 W
Voltage - Isolation 1.5 kV 1.5 kV 1.5 kV
Applications ITE (Commercial) ITE (Commercial) ITE (Commercial)
Operating Temperature -40°C ~ 105°C (With Derating) -40°C ~ 105°C (With Derating) -40°C ~ 105°C (With Derating)
Efficiency 84% 85% 85%
Mounting Type Through Hole Through Hole Through Hole
Package / Case 14-DIP Module, 6 Leads 7-SIP Module, 5 Leads 7-SIP Module, 5 Leads
Size / Dimension 0.80" L x 0.40" W x 0.32" H 0.77" L x 0.28" W x 0.40" H 0.77" L x 0.28" W x 0.40" H
Approval Agency CB Scheme, EN, IEC, UL cURus cURus
Standard Number 55024; 55032 Class A; 60950-1 62368-1 62368-1
RoHS Status RoHS Compliant Not Provided ROHS3 Compliant
Moisture Sensitivity Level (MSL) 1 (Unlimited) Not Provided 1 (Unlimited)
ECCN EAR99 EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580 8504.40.9580

Engineering Selection Recommendations

Substitute selection for the PDM2-S5-D12-D is based directly on product status and explicit compliance information. Both PDME2-S5-D12-D and PDME2-S5-D12-S are designated as active products and maintain key regulatory and environmental standards such as RoHS compliance, MSL 1, and EAR99 classification. Approval agency credentials and certification numbers are provided for each part.

Package style and physical dimension differences must be considered based solely on the provided data. Output configuration differs for substitutes (12V, -12V versus dual 12V); select strictly based on system voltage requirements. Use the environmental and certification details for compliance verification.

Frequently Asked Questions (FAQ)

Q1: What are the critical electrical parameters for substituting PDM2-S5-D12-D?
A1: Allowed substitutes must match input voltage range (4.5V–5.5V), output current (83mA per channel), power (2 W), voltage isolation (1.5 kV), number of outputs (2), mounting type, and application type (ITE-commercial).

Q2: Are there differences in output voltage configuration between the main part and substitutes?
A2: Yes. The PDM2-S5-D12-D provides dual 12V outputs; PDME2-S5-D12-D and PDME2-S5-D12-S provide +12V and -12V outputs.

Q3: How do the substitute packages compare?
A3: The main part is housed in a 14-DIP module (6 leads), while substitutes use a 7-SIP module (5 leads) case. This impacts footprint and pinout considerations.

Q4: Do substitutes maintain environmental and regulatory compliance?
A4: PDME2-S5-D12-S lists ROHS3 and REACH Unaffected; MSL, ECCN, and HTSUS match the main part. Verify all required certifications per provided data.

Q5: Is the efficiency or operating temperature range different in substitutes?
A5: Both substitutes specify 85% efficiency and an operating temperature range of -40°C to 105°C (with derating), compared to 84% for the main part.

Q6: What is the approved application for the substitutes?
A6: All listed products specify ITE (Commercial) applications per the input parameters.

Q7: Can substitutes be interchanged directly regarding mechanical and electrical design?
A7: Interchange is determined strictly by matching key parameters as listed. Mechanical footprint and output voltage configuration differences must be reviewed against design requirements.

Request Quote (Ships tomorrow)