Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts for PBO-10C-3
Part Overview
The PBO-10C-3 (Manufacturer Part Number: PBO-10C-3; Manufacturer: CUI Inc.) is an open frame AC/DC converter with a single 3.3V output at up to 2A, providing 6.6W power. Its input range is 85 ~ 305 VAC or 100 ~ 430 VDC. The converter features through-hole mounting in a 6-SIP module case. Primary applications include household appliances and ITE (Commercial). The product is listed as obsolete, necessitating the identification of equivalent or substitute models for continued design or maintenance compatibility.
Substiute Parts
Key Parameters
| Parameter | PBO-10C-3 |
|---|---|
| Manufacturer | CUI Inc. |
| Series | PBO-10C |
| Product Status | Obsolete |
| Type | Open Frame |
| Number of Outputs | 1 |
| Voltage - Input | 85 ~ 305 VAC, 100 ~ 430 VDC |
| Voltage - Output 1 | 3.3V |
| Current - Output (Max) | 2A |
| Power (Watts) | 6.6 W |
| Applications | Household Appliances, ITE (Commercial) |
| Operating Temperature | -40°C ~ 85°C (With Derating) |
| Efficiency | 73% |
| Mounting Type | Through Hole |
| Package / Case | 6-SIP Module |
| Size / Dimension | 1.26" L x 0.59" W x 0.68" H (32.0mm x 15.0mm x 17.2mm) |
| Approval Agency | CE, cURus |
| Standard Number | 60335-1; 62368-1 |
| Line Regulation | ±1% |
| Load Regulation | ±1.5% |
| RoHS Status | RoHS Compliant |
| Moisture Sensitivity Level (MSL) | Not Applicable |
| ECCN | EAR99 |
| HTSUS | 8504.40.9510 |
Substitute Part Grouping Explanation
The substitute part group is defined strictly by conformity to the following key parameters from the AC/DC converter product category: single output configuration, identical input voltage range, matching output voltage of 3.3V, open frame type, suitable mounting method (through hole), applicable regulatory approvals (CE, cURus), and RoHS compliance. The substitute part included is strictly listed as a manufacturer-recommended alternative, meeting these criteria.
Key parameters for substitution:
- Voltage - Input
- Voltage - Output 1
- Number of Outputs
- Type
- Mounting Type
- Approval Agency
- RoHS Status
- Applications
- Operating Temperature Range
Parameter Comparison
| Parameter | PBO-10C-3 | PBO-15C-3 |
|---|---|---|
| Manufacturer | CUI Inc. | CUI Inc. |
| Series | PBO-10C | PBO-15C |
| Product Status | Obsolete | Active |
| Type | Open Frame | Open Frame |
| Number of Outputs | 1 | 1 |
| Voltage - Input | 85 ~ 305 VAC, 100 ~ 430 VDC | 85 ~ 305 VAC, 100 ~ 430 VDC |
| Voltage - Output 1 | 3.3V | 3.3V |
| Current - Output (Max) | 2A | 3A |
| Power (Watts) | 6.6 W | 9.9 W |
| Applications | Household Appliances, ITE (Commercial) | Household Appliances, ITE (Commercial) |
| Operating Temperature | -40°C ~ 85°C (With Derating) | -40°C ~ 85°C (With Derating) |
| Efficiency | 73% | 75% |
| Mounting Type | Through Hole | Through Hole |
| Package / Case | 6-SIP Module | 16-SIP Module, 6 Leads |
| Size / Dimension | 1.26" L x 0.59" W x 0.68" H | 1.75" L x 0.59" W x 0.94" H |
| Approval Agency | CE, cURus | CE, cURus, UL |
| Line Regulation | ±1% | ±0.5% |
| Load Regulation | ±1.5% | ±2% |
| RoHS Status | RoHS Compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | Not Applicable | Not Applicable |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9510 | 8504.40.9510 |
Engineering Selection Recommendations
Selection between PBO-10C-3 and PBO-15C-3 is determined by product status, available certifications, and compliance standards. PBO-10C-3 is obsolete, while PBO-15C-3 is active and ROHS3 Compliant, meeting CE and cURus agency approvals with added UL certification. Both products offer the required input/output parameters, operating temperature range, and mounting configuration for household appliances or ITE (Commercial) applications. Substitute selection is permitted within these strictly matched criteria.
Frequently Asked Questions (FAQ)
Q: What substitute is available for the obsolete PBO-10C-3 AC/DC converter?
A: The manufacturer-recommended substitute is PBO-15C-3, which matches core electrical and mechanical specifications for the product category.
Q: Are the input and output voltage specifications identical between these models?
A: Both PBO-10C-3 and PBO-15C-3 provide an input range of 85 ~ 305 VAC, 100 ~ 430 VDC and a single output voltage of 3.3V.
Q: Is mechanical compatibility maintained in terms of mounting and package type?
A: Both models feature through-hole mounting; PBO-15C-3 package dimensions and case configuration differ in length and height, requiring assessment for PCB layout conformity.
Q: Which approvals and compliance certifications do the substitute part offer?
A: PBO-15C-3 is CE, cURus, and UL certified and is ROHS3 compliant.
Q: What parameter differences should be considered when substituting?
A: Key differences include output current (PBO-15C-3 provides 3A max versus 2A for the original) and package dimension. Dimensions and regulatory certification should be verified against target application and mechanical requirements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts