P3002AB Equivalent & Substitute Parts
Part Overview
The P3002AB is a Transient Voltage Suppressor (TVS) thyristor manufactured by Littelfuse Inc. in the SIDACtor® series. This component is designed for overvoltage protection applications, featuring dual-element configuration with 140V/280V off-state voltage ratings and 250A peak pulse current capability in a 3-SIP TO-220 Modified package. The P3002AB is currently classified as obsolete, making identification of suitable substitute components essential for ongoing system support and new design implementations.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Voltage - Breakover | 180V, 360V |
| Voltage - Off State | 140V, 280V |
| Voltage - On State | 4 V |
| Current - Peak Pulse (8/20µs) | 250 A |
| Current - Peak Pulse (10/1000µs) | 80 A |
| Current - Hold (Ih) | 150 mA |
| Number of Elements | 2 |
| Capacitance | 55pF, 95pF |
| Package / Case | 3-SIP |
| Mounting Type | Through Hole |
Substitute Part Grouping Explanation
Substitution of the P3002AB is determined by electrical and mechanical parameter equivalence. The following criteria establish valid substitute relationships:
- Voltage ratings must match exactly: Breakover voltage (180V, 360V), Off-State voltage (140V, 280V), and On-State voltage (4V)
- Peak pulse current specifications must be identical: 250A at 8/20µs and 80A at 10/1000µs
- Hold current (Ih) must equal 150 mA
- Number of elements must remain 2
- Capacitance values must match: 55pF and 95pF
- Package configuration must be 3-SIP with Through Hole mounting
- Supplier Device Package must be TO-220 Modified
The P3002ABL meets all these criteria and qualifies as a direct substitute for the obsolete P3002AB.
Parameter Comparison
| Parameter | P3002AB (Main) | P3002ABL (Substitute) |
|---|---|---|
| Manufacturer | Littelfuse Inc. | Littelfuse Inc. |
| Series | SIDACtor® | SIDACtor® |
| Category | Transient Voltage Suppressors (TVS) | Transient Voltage Suppressors (TVS) |
| Voltage - Breakover | 180V, 360V | 180V, 360V |
| Voltage - Off State | 140V, 280V | 140V, 280V |
| Voltage - On State | 4 V | 4 V |
| Current - Peak Pulse (8/20µs) | 250 A | 250 A |
| Current - Peak Pulse (10/1000µs) | 80 A | 80 A |
| Current - Hold (Ih) | 150 mA | 150 mA |
| Number of Elements | 2 | 2 |
| Capacitance | 55pF, 95pF | 55pF, 95pF |
| Package / Case | 3-SIP | 3-SIP |
| Mounting Type | Through Hole | Through Hole |
| Supplier Device Package | TO-220 Modified | TO-220 Modified |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS non-compliant | ROHS3 Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) | 1 (Unlimited) |
Engineering Selection Recommendations
The P3002ABL is the direct substitute for the obsolete P3002AB. Both components share identical electrical and mechanical specifications, ensuring functional equivalence in circuit applications. The primary distinction between these parts is product status and regulatory compliance.
The P3002AB is classified as obsolete and carries RoHS non-compliant status. The P3002ABL is an active product with ROHS3 compliance and REACH Unaffected designation, making it suitable for applications subject to current environmental and regulatory requirements. Both components maintain identical Moisture Sensitivity Level (MSL) classification of 1 (Unlimited), indicating no special moisture handling requirements during storage or assembly.
Selection of the P3002ABL over the P3002AB is appropriate for new designs, system upgrades, and long-term component availability assurance.
Frequently Asked Questions (FAQ)
Q: Can the P3002ABL be used as a direct replacement for the P3002AB in existing designs?
A: Yes. The P3002ABL provides complete electrical and mechanical equivalence to the P3002AB. All voltage ratings, current specifications, element count, capacitance values, and package configuration are identical. Direct substitution is possible without circuit modification.
Q: What is the primary reason to transition from P3002AB to P3002ABL?
A: The P3002AB is obsolete. The P3002ABL is an active product from the same manufacturer and series, ensuring ongoing availability and supply chain continuity. Additionally, the P3002ABL meets ROHS3 compliance standards, whereas the P3002AB does not.
Q: Are there any differences in thermal or mechanical handling between these parts?
A: Both components share identical Moisture Sensitivity Level (MSL) classification of 1 (Unlimited), indicating equivalent handling requirements. No special moisture control measures are necessary during storage or assembly for either part.
Q: Does the P3002ABL maintain the same 3-SIP TO-220 Modified package configuration?
A: Yes. The P3002ABL uses the identical 3-SIP package with TO-220 Modified supplier device package designation. Through-hole mounting compatibility is maintained.
Q: What certifications and compliance standards apply to the P3002ABL?
A: The P3002ABL is ROHS3 compliant and REACH Unaffected. The P3002AB is RoHS non-compliant. Both components carry EAR99 ECCN classification and 8541.30.0080 HTSUS code.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts