OKY-T/10-W5P-C Equivalent & Substitute Parts

Part Overview

The Murata Power Solutions Inc. OKY-T/10-W5P-C is a Non-Isolated PoL Module DC DC Converter. It features a single programmable output voltage range of 0.75 V to 3.63 V, a 10 A maximum output current, and supports a 2.4 V to 5.5 V input. This model is obsolete; therefore, it is essential to identify suitable alternative DC-DC converter modules with compatible parameters for continued designs and component sourcing.

Substiute Parts

OKY-T/10-W5P-C
Murata Power Solutions Inc.In Stock: 714OKY-T/10-W5P-C Datasheet
OKY-T/10-W5P-C
Current Part
YS05S10-0G
Bel Power SolutionsIn Stock: 1192YS05S10-0G Datasheet
YS05S10-0G
MFR Recommended

Key Parameters

ParameterOKY-T/10-W5P-C Value
TypeNon-Isolated PoL Module
Number of Outputs1
Voltage - Input (Min)2.4V
Voltage - Input (Max)5.5V
Voltage - Output 10.75 ~ 3.63V
Current - Output (Max)10A
Power (Watts)33 W
ApplicationsITE (Commercial)
FeaturesRemote On/Off, OCP, OTP, SCP, UVLO
Operating Temperature-40°C ~ 85°C
Efficiency95%
Mounting TypeSurface Mount
Package / Case7-SMD Module, 6 Leads
Size / Dimension1.30" L x 0.53" W x 0.33" H (33.0mm x 13.5mm x 8.4mm)
Control FeaturesEnable, Active High
RoHS StatusRoHS Compliant
MSL2 (1 Year)
REACH StatusREACH Unaffected
ECCNEAR99
HTSUS8504.40.9580
Product StatusObsolete

Substitute Part Grouping Explanation

Substitute parts for the OKY-T/10-W5P-C DC DC converter are determined by matching the following key parameters: module type (Non-Isolated PoL), output configuration (1 output), input voltage range, output voltage range, maximum output current, application range, feature set, surface-mount packaging, thermal performance (operating temperature), and compliance (RoHS, REACH, ECCN, HTSUS, MSL). Only parts matching or exceeding these parameters are considered for substitution.

Parameter Comparison

Parameter OKY-T/10-W5P-C YS05S10-0G
Manufacturer Murata Power Solutions Inc. Bel Power Solutions
Type Non-Isolated PoL Module Non-Isolated PoL Module
Number of Outputs 1 1
Voltage - Input (Min) 2.4V 3V
Voltage - Input (Max) 5.5V 5.5V
Voltage - Output 1 0.75 ~ 3.63V 0.75 ~ 3.63V
Current - Output (Max) 10A 10A
Power (Watts) 33 W 36 W
Applications ITE (Commercial) ITE (Commercial)
Features Remote On/Off, OCP, OTP, SCP, UVLO Remote On/Off, OCP, OTP, UVLO
Operating Temperature -40°C ~ 85°C -40°C ~ 85°C
Efficiency 95% 94.5%
Mounting Type Surface Mount Surface Mount
Package / Case 7-SMD Module, 6 Leads 6-SMD Module
Size / Dimension 1.30" L x 0.53" W x 0.33" H (33.0mm x 13.5mm x 8.4mm) 1.30" L x 0.53" W x 0.31" H (33.0mm x 13.5mm x 7.9mm)
Control Features Enable, Active High Enable, Active High
RoHS Status RoHS Compliant ROHS3 Compliant
MSL 2 (1 Year) 1 (Unlimited)
REACH Status REACH Unaffected REACH Unaffected
ECCN EAR99 EAR99
HTSUS 8504.40.9580 8504.40.9580
Product Status Obsolete Active

Engineering Selection Recommendations

The OKY-T/10-W5P-C is classified as obsolete, while the YS05S10-0G is currently active. Both units comply with RoHS and REACH requirements and are classified under ECCN EAR99 and HTSUS 8504.40.9580. For RoHS and REACH-compliant designs, or where MSL and supply continuity are critical, YS05S10-0G is an eligible substitute in matching package and application conditions.

Frequently Asked Questions (FAQ)

Q1: What criteria are used to determine substitute compatibility for OKY-T/10-W5P-C?
A1: Substitute compatibility is established solely on identical module type, single output, matching input and output voltage ranges, current capacity, package type, mounting method, and compliance standards.

Q2: Are the physical package and mounting type equivalent between OKY-T/10-W5P-C and YS05S10-0G?
A2: Both are surface-mount modules with near-identical dimensions. Review of layout compatibility is required based strictly on provided package dimensions and lead arrangement.

Q3: Is there a difference in environmental and compliance certifications between the part numbers?
A3: Both OKY-T/10-W5P-C and YS05S10-0G are RoHS and REACH compliant, and are classified under ECCN EAR99 and HTSUS 8504.40.9580.

Q4: Are there differences in the electrical feature set?
A4: The primary feature set is consistent across both models (Remote On/Off, OCP, OTP, UVLO). SCP is present in OKY-T/10-W5P-C and not listed for YS05S10-0G. All other features align per provided data.

Q5: What is the importance of Product Status in substitutions?
A5: Product status distinguishes availability; the original part is obsolete, while the substitute is active, ensuring ongoing supply for new designs or replacements.

Request Quote (Ships tomorrow)