Request Quote
(Ships tomorrow)
OKY-T/10-W5P-C Equivalent & Substitute Parts
Part Overview
The Murata Power Solutions Inc. OKY-T/10-W5P-C is a Non-Isolated PoL Module DC DC Converter. It features a single programmable output voltage range of 0.75 V to 3.63 V, a 10 A maximum output current, and supports a 2.4 V to 5.5 V input. This model is obsolete; therefore, it is essential to identify suitable alternative DC-DC converter modules with compatible parameters for continued designs and component sourcing.
Substiute Parts
Key Parameters
| Parameter | OKY-T/10-W5P-C Value |
|---|---|
| Type | Non-Isolated PoL Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 2.4V |
| Voltage - Input (Max) | 5.5V |
| Voltage - Output 1 | 0.75 ~ 3.63V |
| Current - Output (Max) | 10A |
| Power (Watts) | 33 W |
| Applications | ITE (Commercial) |
| Features | Remote On/Off, OCP, OTP, SCP, UVLO |
| Operating Temperature | -40°C ~ 85°C |
| Efficiency | 95% |
| Mounting Type | Surface Mount |
| Package / Case | 7-SMD Module, 6 Leads |
| Size / Dimension | 1.30" L x 0.53" W x 0.33" H (33.0mm x 13.5mm x 8.4mm) |
| Control Features | Enable, Active High |
| RoHS Status | RoHS Compliant |
| MSL | 2 (1 Year) |
| REACH Status | REACH Unaffected |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
| Product Status | Obsolete |
Substitute Part Grouping Explanation
Substitute parts for the OKY-T/10-W5P-C DC DC converter are determined by matching the following key parameters: module type (Non-Isolated PoL), output configuration (1 output), input voltage range, output voltage range, maximum output current, application range, feature set, surface-mount packaging, thermal performance (operating temperature), and compliance (RoHS, REACH, ECCN, HTSUS, MSL). Only parts matching or exceeding these parameters are considered for substitution.
Parameter Comparison
| Parameter | OKY-T/10-W5P-C | YS05S10-0G |
|---|---|---|
| Manufacturer | Murata Power Solutions Inc. | Bel Power Solutions |
| Type | Non-Isolated PoL Module | Non-Isolated PoL Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 2.4V | 3V |
| Voltage - Input (Max) | 5.5V | 5.5V |
| Voltage - Output 1 | 0.75 ~ 3.63V | 0.75 ~ 3.63V |
| Current - Output (Max) | 10A | 10A |
| Power (Watts) | 33 W | 36 W |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | Remote On/Off, OCP, OTP, SCP, UVLO | Remote On/Off, OCP, OTP, UVLO |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Efficiency | 95% | 94.5% |
| Mounting Type | Surface Mount | Surface Mount |
| Package / Case | 7-SMD Module, 6 Leads | 6-SMD Module |
| Size / Dimension | 1.30" L x 0.53" W x 0.33" H (33.0mm x 13.5mm x 8.4mm) | 1.30" L x 0.53" W x 0.31" H (33.0mm x 13.5mm x 7.9mm) |
| Control Features | Enable, Active High | Enable, Active High |
| RoHS Status | RoHS Compliant | ROHS3 Compliant |
| MSL | 2 (1 Year) | 1 (Unlimited) |
| REACH Status | REACH Unaffected | REACH Unaffected |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
| Product Status | Obsolete | Active |
Engineering Selection Recommendations
The OKY-T/10-W5P-C is classified as obsolete, while the YS05S10-0G is currently active. Both units comply with RoHS and REACH requirements and are classified under ECCN EAR99 and HTSUS 8504.40.9580. For RoHS and REACH-compliant designs, or where MSL and supply continuity are critical, YS05S10-0G is an eligible substitute in matching package and application conditions.
Frequently Asked Questions (FAQ)
Q1: What criteria are used to determine substitute compatibility for OKY-T/10-W5P-C?
A1: Substitute compatibility is established solely on identical module type, single output, matching input and output voltage ranges, current capacity, package type, mounting method, and compliance standards.
Q2: Are the physical package and mounting type equivalent between OKY-T/10-W5P-C and YS05S10-0G?
A2: Both are surface-mount modules with near-identical dimensions. Review of layout compatibility is required based strictly on provided package dimensions and lead arrangement.
Q3: Is there a difference in environmental and compliance certifications between the part numbers?
A3: Both OKY-T/10-W5P-C and YS05S10-0G are RoHS and REACH compliant, and are classified under ECCN EAR99 and HTSUS 8504.40.9580.
Q4: Are there differences in the electrical feature set?
A4: The primary feature set is consistent across both models (Remote On/Off, OCP, OTP, UVLO). SCP is present in OKY-T/10-W5P-C and not listed for YS05S10-0G. All other features align per provided data.
Q5: What is the importance of Product Status in substitutions?
A5: Product status distinguishes availability; the original part is obsolete, while the substitute is active, ensuring ongoing supply for new designs or replacements.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts