Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts for OKY-T/10-D12P-C
Part Overview
The Murata Power Solutions Inc. OKY-T/10-D12P-C is a Non-Isolated PoL Module DC-DC converter with an output voltage range of 0.75V to 5.5V at 10A and an input voltage range of 8.3V to 14V. It is capable of delivering up to 50W and includes standard features such as Remote On/Off, OCP, OTP, SCP, and UVLO. The OKY-T/10-D12P-C is categorized as obsolete, making finding equivalent substitute parts essential to support ongoing designs, replacement needs, or continued manufacturing where this model was previously used.
Substiute Parts
Key Parameters
| Parameter | OKY-T/10-D12P-C |
|---|---|
| Type | Non-Isolated PoL Module |
| Number of Outputs | 1 |
| Voltage - Input (Min) | 8.3V |
| Voltage - Input (Max) | 14V |
| Voltage - Output 1 | 0.75 ~ 5.5V |
| Current - Output (Max) | 10A |
| Power (Watts) | 50 W |
| Applications | ITE (Commercial) |
| Features | Remote On/Off, OCP, OTP, SCP, UVLO |
| Operating Temperature | -40°C ~ 85°C |
| Efficiency | 94.5% |
| Mounting Type | Surface Mount |
| Package / Case | 7-SMD Module, 6 Leads |
| Size / Dimension | 1.30" L x 0.53" W x 0.33" H (33.0mm x 13.5mm x 8.4mm) |
| Control Features | Enable, Active High |
| RoHS Status | RoHS Compliant |
| MSL | 2 (1 Year) |
| ECCN | EAR99 |
| HTSUS | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitute DC-DC converters are selected by matching the following key parameters: type (Non-Isolated PoL Module), number of outputs (1), input voltage range, output voltage range, output current rating, features (Remote On/Off, OCP, OTP, SCP, UVLO), mounting style (Surface Mount), package type, operational temperature range, and compliance standards. Only parts that strictly match or exceed all listed input and output specifications, operational features, limits, and certifications are included as substitutes.
Key parameters used for substitution:
- Type
- Number of Outputs
- Input Voltage (Min/Max)
- Output Voltage Range
- Output Current (Max)
- Features
- Operating Temperature Range
- Mounting Type
- Package / Case
- Control Features
- RoHS Status
Parameter Comparison
| Parameter | OKY-T/10-D12P-C Murata Power Solutions Inc. |
AXA010A0X3-SRZ OmniOn Power |
|---|---|---|
| Type | Non-Isolated PoL Module | Non-Isolated PoL Module |
| Number of Outputs | 1 | 1 |
| Voltage - Input (Min) | 8.3V | 10V |
| Voltage - Input (Max) | 14V | 14V |
| Voltage - Output 1 | 0.75 ~ 5.5V | 0.8 ~ 5.5V |
| Current - Output (Max) | 10A | 10A |
| Power (Watts) | 50 W | 55 W |
| Applications | ITE (Commercial) | ITE (Commercial) |
| Features | Remote On/Off, OCP, OTP, SCP, UVLO | Remote On/Off, OCP, OTP, UVLO |
| Operating Temperature | -40°C ~ 85°C | -40°C ~ 85°C |
| Efficiency | 94.5% | 93% |
| Mounting Type | Surface Mount | Surface Mount |
| Package / Case | 7-SMD Module, 6 Leads | 6-SMD Module |
| Size / Dimension | 1.30" L x 0.53" W x 0.33" H (33.0mm x 13.5mm x 8.4mm) | 1.30" L x 0.43" W x 0.33" H (33.0mm x 10.9mm x 8.3mm) |
| Control Features | Enable, Active High | Enable, Active High |
| RoHS Status | RoHS Compliant | RoHS Compliant |
| MSL | 2 (1 Year) | 2A (4 Weeks) |
| ECCN | EAR99 | EAR99 |
| HTSUS | 8504.40.9580 | 8504.40.9580 |
Engineering Selection Recommendations
As the Murata OKY-T/10-D12P-C is obsolete, selection of substitute DC-DC converters must be based on matching the electrical and mechanical parameters, documented operational features, and compliance criteria provided. Substitute options such as the OmniOn Power AXA010A0X3-SRZ are considered based exclusively on RoHS compliance, product status, MSL ratings, and other certification equivalence as listed.
Frequently Asked Questions (FAQ)
Q1: What electrical parameters are most critical when selecting a DC-DC converter substitute?
A1: The most critical parameters are number of outputs, input voltage range, output voltage range, maximum output current, and essential features (such as Remote On/Off, OCP, OTP, SCP, UVLO).
Q2: Are the control features and package type important for drop-in replacement?
A2: Yes. Control features (such as Enable, Active High) and matching package/case type and pin count are crucial for mechanical and functional compatibility.
Q3: How does operating temperature range impact substitution?
A3: The operating temperature range must match to ensure the substitute part performs reliably in the same environmental envelope.
Q4: What compliance and certification standards are required in the selection process?
A4: RoHS compliance, MSL rating, and matching ECCN and HTSUS codes are required for regulatory and supply chain compatibility.
Q5: Can mounting differences affect compatibility?
A5: Surface mount configuration is required for mechanical compatibility. Differences in size or lead count may affect board re-layout or qualification.
Q6: Is it necessary to consider efficiency differences between substitutes?
A6: Efficiency is a key parameter when matching substitute DC-DC converters and must be within acceptable ranges specified in the input.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts