Request Quote
(Ships tomorrow)
Equivalent & Substitute Parts Reference for NCM6S4812C
Part Overview
The Murata Power Solutions Inc. NCM6S4812C is an isolated DC-DC converter module with a single 12V output at up to 500mA, supporting input voltages from 18V to 75V and rated for 6W total output power. This module features a 5.2kV isolation voltage, remote on/off control, over-temperature protection (OTP), short circuit protection (SCP), and under-voltage lockout (UVLO). It is designed for ITE (Commercial) and Medical applications and utilizes a through-hole 24-DIP module package. The product is currently categorized as obsolete, making it necessary to identify suitable substitute models for ongoing or new designs requiring comparable electrical and mechanical performance.
Substiute Parts
Key Parameters
| Manufacturer Part Number | Series | Status | Type | Number of Outputs | Input Voltage Min (V) | Input Voltage Max (V) | Output Voltage 1 (V) | Output Current Max (mA) | Power (W) | Isolation Voltage (kV) | Applications | Features | Operating Temp (°C) | Efficiency (%) | Mounting Type | Package / Case | Dimensions (mm) | RoHS Status | MSL | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| NCM6S4812C | NCM6 (6W) | Obsolete | Isolated Module | 1 | 18 | 75 | 12 | 500 | 6 | 5.2 | ITE (Commercial), Medical | Remote On/Off, OTP, SCP, UVLO | -40 ~ 85 | 82 | Through Hole | 24-DIP Module, 7 Leads | 32.0 x 20.0 x 10.8 | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 |
| NCS6S4812C | NCS6 (6W) | Active | Isolated Module | 1 | 18 | 75 | 12 | 500 | 6 | 1.5 | ITE (Commercial) | - | -40 ~ 85 | 84 | Through Hole | 24-DIP Module (600 mil, 7 Leads) | 32.0 x 20.1 x 9.9 | ROHS3 Compliant | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 |
Substitute Part Grouping Explanation
Substitution for the Murata Power Solutions Inc. NCM6S4812C is limited to modules matching the following explicit parameters: single output channel, input voltage range of 18V to 75V, output voltage of 12V, maximum output current of 500mA, power rating of 6W, through-hole mounting, 24-DIP module package, and comparable operating temperature range. Additional criteria include matching RoHS compliance and moisture sensitivity level. Only parts with all specified parameters are considered direct substitutes.
Parameter Comparison
| Manufacturer Part Number | Status | Type | Number of Outputs | Input Voltage Min (V) | Input Voltage Max (V) | Output Voltage 1 (V) | Output Current Max (mA) | Power (W) | Isolation Voltage (kV) | Applications | Operating Temp (°C) | Efficiency (%) | Mounting Type | Package / Case | Dimensions (mm) | RoHS Status | MSL | REACH Status | ECCN | HTSUS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| NCM6S4812C | Obsolete | Isolated Module | 1 | 18 | 75 | 12 | 500 | 6 | 5.2 | ITE (Commercial), Medical | -40 ~ 85 | 82 | Through Hole | 24-DIP Module, 7 Leads | 32.0 x 20.0 x 10.8 | ROHS3 Compliant | Not Applicable | REACH Unaffected | EAR99 | 8504.40.9580 |
| NCS6S4812C | Active | Isolated Module | 1 | 18 | 75 | 12 | 500 | 6 | 1.5 | ITE (Commercial) | -40 ~ 85 | 84 | Through Hole | 24-DIP Module (600 mil, 7 Leads) | 32.0 x 20.1 x 9.9 | ROHS3 Compliant | Not Applicable | REACH Affected | EAR99 | 8504.40.9580 |
Engineering Selection Recommendations
Selection of NCS6S4812C as a substitute for the obsolete NCM6S4812C should be based exclusively on matching product status (active), RoHS3 compliance, and the specified moisture sensitivity level. Both parts are rated as “ROHS3 Compliant” and “Not Applicable” for MSL. For regulatory requirements, review the provided REACH and other certifications before final selection if mandated by end-use application.
Frequently Asked Questions (FAQ)
Q1: What parameters must exactly match when substituting the NCM6S4812C?
A1: Substitute modules must match number of outputs, input and output voltage range, output current, power rating, mounting type, package/case, size, and feature comparable RoHS and MSL status.
Q2: Are there differences in isolation voltage between NCM6S4812C and NCS6S4812C?
A2: Yes. NCM6S4812C specifies a 5.2 kV isolation voltage; NCS6S4812C specifies 1.5 kV. All other key electrical and mechanical parameters as listed are equivalent.
Q3: Is the package form factor the same for both parts?
A3: Both devices use a 24-DIP module with 7 leads and through-hole mounting, with similar but not identical dimensions.
Q4: Are there differences in compliance status?
A4: Both parts are RoHS3 compliant. Refer to the REACH status if that is a requirement for the product or application.
Q5: Which substitute part is directly listed by the manufacturer?
A5: NCS6S4812C is listed as the manufacturer-recommended substitute for NCM6S4812C.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts