NBPDANS150PGUNV Equivalent & Substitute Parts

Part Overview

The NBPDANS150PGUNV is a pressure sensor manufactured by Honeywell Sensing and Productivity Solutions, designed for board mount applications requiring vented gauge pressure measurement. This component operates across a 150 PSI (1034.21 kPa) range with a Wheatstone Bridge output configuration. The part is currently classified as obsolete, making identification of equivalent substitute components essential for ongoing system support and procurement planning. Active equivalent models are available to ensure design continuity and supply chain reliability.

Substiute Parts

NBPDANS150PGUNV
Honeywell Sensing and Productivity SolutionsIn Stock: 1105NBPDANS150PGUNV Datasheet
NBPDANS150PGUNV
Current Part
NBPDANN150PGUNV
Honeywell Sensing and Productivity SolutionsIn Stock: 1024NBPDANN150PGUNV Datasheet
NBPDANN150PGUNV
Parametric Equivalent

Key Parameters

Parameter Value
Operating Pressure Range 150 PSI (1034.21 kPa)
Pressure Type Vented Gauge
Output Type Wheatstone Bridge
Output Signal 0 mV ~ 130 mV (5V)
Accuracy ±0.25%
Supply Voltage 1.8V ~ 12V
Port Configuration Male - 0.08" (1.91mm) Tube, Barbed
Maximum Pressure 240 PSI (1654.74 kPa)
Operating Temperature -40°C ~ 125°C
Package Type 4-DIP (0.453", 11.50mm), Top Port
Mounting Type Through Hole
Termination Style PC Pin
RoHS Compliance RoHS Compliant
Moisture Sensitivity Level 1 (Unlimited)

Substitute Part Grouping Explanation

Substitution of the NBPDANS150PGUNV is determined by strict equivalence across all critical electrical and mechanical parameters. The substitute component must maintain identical specifications in the following areas:

Pressure Specifications: Operating pressure of 150 PSI (1034.21 kPa) and maximum pressure rating of 240 PSI (1654.74 kPa) are non-negotiable for system compatibility.

Signal Characteristics: Output type (Wheatstone Bridge), output range (0 mV ~ 130 mV at 5V), and accuracy (±0.25%) must be preserved to ensure signal integrity in existing circuit designs.

Electrical Interface: Supply voltage range (1.8V ~ 12V) and termination style (PC Pin) must match to enable direct board-level integration.

Physical Configuration: Port size (Male - 0.08" / 1.91mm Tube), port style (Barbed), package type (4-DIP with 0.453" / 11.50mm dimensions), and mounting method (Through Hole) must be identical for mechanical fit and installation compatibility.

Environmental Compliance: RoHS compliance and moisture sensitivity level (MSL 1) must be maintained for regulatory and reliability requirements.

Parameter Comparison

Parameter NBPDANS150PGUNV (Main Part) NBPDANN150PGUNV (Substitute) Match Status
Manufacturer Honeywell Sensing and Productivity Solutions Honeywell Sensing and Productivity Solutions Identical
Operating Pressure 150 PSI (1034.21 kPa) 150 PSI (1034.21 kPa) Identical
Pressure Type Vented Gauge Vented Gauge Identical
Output Type Wheatstone Bridge Wheatstone Bridge Identical
Output Signal 0 mV ~ 130 mV (5V) 0 mV ~ 130 mV (5V) Identical
Accuracy ±0.25% ±0.25% Identical
Supply Voltage 1.8V ~ 12V 1.8V ~ 12V Identical
Port Size Male - 0.08" (1.91mm) Tube Male - 0.08" (1.91mm) Tube Identical
Port Style Barbed Barbed Identical
Maximum Pressure 240 PSI (1654.74 kPa) 240 PSI (1654.74 kPa) Identical
Operating Temperature -40°C ~ 125°C -40°C ~ 125°C Identical
Package Type 4-DIP (0.453", 11.50mm), Top Port 4-DIP (0.453", 11.50mm), Top Port Identical
Mounting Type Through Hole Through Hole Identical
Termination Style PC Pin PC Pin Identical
RoHS Status RoHS Compliant RoHS Compliant Identical
Moisture Sensitivity Level 1 (Unlimited) 1 (Unlimited) Identical
Product Status Obsolete Active Substitute is Active

Engineering Selection Recommendations

The NBPDANN150PGUNV is a direct parametric equivalent to the obsolete NBPDANS150PGUNV. All electrical, mechanical, and environmental specifications are identical across both components. The primary distinction is product status: NBPDANS150PGUNV is classified as obsolete, while NBPDANN150PGUNV maintains active status with current manufacturing support.

For new designs or system replacements, NBPDANN150PGUNV is the appropriate selection. Both components are manufactured by Honeywell Sensing and Productivity Solutions and carry identical RoHS compliance certification. The substitute part maintains full compatibility with existing circuit designs, PCB layouts, and pressure system interfaces without requiring design modifications.

Current inventory availability shows 991 pieces of NBPDANN150PGUNV in stock, supporting immediate procurement requirements.

Frequently Asked Questions (FAQ)

Q: Can NBPDANN150PGUNV be used as a direct replacement for NBPDANS150PGUNV?

A: Yes. NBPDANN150PGUNV is a parametric equivalent with identical electrical output (0 mV ~ 130 mV Wheatstone Bridge), pressure range (150 PSI), accuracy (±0.25%), supply voltage (1.8V ~ 12V), physical package (4-DIP Through Hole), and port configuration (Male 0.08" Barbed). No circuit or mechanical modifications are required.

Q: What is the difference between these two part numbers?

A: The primary difference is product status. NBPDANS150PGUNV is obsolete, while NBPDANN150PGUNV is active with current manufacturing support. All technical specifications, performance characteristics, and compliance certifications are identical.

Q: Are there any packaging differences?

A: Both components use identical 4-DIP (0.453", 11.50mm) packages with Through Hole mounting and PC Pin termination. The main part was supplied with standard packaging, while the substitute is available in bulk packaging. This does not affect component functionality or board-level integration.

Q: Is RoHS compliance maintained with the substitute?

A: Yes. Both NBPDANS150PGUNV and NBPDANN150PGUNV are RoHS Compliant with Moisture Sensitivity Level 1 (Unlimited). Regulatory and environmental requirements are fully preserved.

Q: What is the operating temperature range?

A: Both components operate across -40°C to 125°C, supporting applications in industrial, automotive, and environmental extremes within this specification.

Q: Can I use this sensor for absolute pressure measurement?

A: No. Both components are configured for vented gauge pressure measurement only. Vented gauge configuration means atmospheric pressure is referenced through a vent port, making these sensors unsuitable for absolute or sealed gauge applications.

Request Quote (Ships tomorrow)