Request Quote
(Ships tomorrow)
MY4N-GS DC6 Equivalent & Substitute Parts
Part Overview
The MY4N-GS DC6 is a general purpose relay manufactured by Omron Automation and Safety, featuring a 4PDT (4 Form C) contact configuration with a 6VDC coil. This component is classified as obsolete, though 852 pieces remain available in new original stock. Due to its obsolete status, identifying functionally equivalent substitute parts is essential for ongoing system maintenance, repair, and new design implementations where this relay type is specified.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer | Omron Automation and Safety |
| Series | MY |
| Coil Voltage | 6VDC |
| Contact Form | 4PDT (4 Form C) |
| Switching Voltage | 250VAC, 220VDC - Max |
| Coil Type | Non Latching |
| Relay Type | General Purpose |
| Product Status | Obsolete |
| RoHS Status | RoHS Compliant |
| MSL Rating | 1 (Unlimited) |
Substitute Part Grouping Explanation
Substitution of the MY4N-GS DC6 is determined by the following critical parameters:
- Coil Voltage: Must be 6VDC to maintain circuit compatibility
- Contact Form: Must be 4PDT (4 Form C) to preserve switching functionality
- Switching Voltage Rating: Must support 250VAC, 220VDC maximum to ensure safe operation in the target application
- Coil Type: Must be Non Latching to match operational behavior
- Relay Type: Must be General Purpose to align with application requirements
- RoHS Compliance: Must maintain RoHS Compliant status for regulatory adherence
The MY4N-GS-R DC6 satisfies all these criteria while offering an active product status and enhanced features including socketable mounting, mechanical and lighted indicators, and documented electrical performance specifications.
Parameter Comparison
| Parameter | MY4N-GS DC6 (Main Part) | MY4N-GS-R DC6 (Substitute) |
|---|---|---|
| Manufacturer | Omron Automation and Safety | Omron Automation and Safety |
| Series | MY | MY |
| Coil Voltage | 6VDC | 6VDC |
| Contact Form | 4PDT (4 Form C) | 4PDT (4 Form C) |
| Switching Voltage | 250VAC, 220VDC - Max | 250VAC, 220VDC - Max |
| Coil Type | Non Latching | Non Latching |
| Relay Type | General Purpose | General Purpose |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS Compliant | RoHS Compliant |
| MSL Rating | 1 (Unlimited) | Not specified |
| Contact Rating (Current) | Not specified | 6 A |
| Coil Current | Not specified | 151 mA |
| Must Operate Voltage | Not specified | 4.8 VDC |
| Must Release Voltage | Not specified | 0.6 VDC |
| Operate Time | Not specified | 20 ms |
| Release Time | Not specified | 20 ms |
| Operating Temperature | Not specified | -40°C ~ 70°C |
| Contact Material | Not specified | Silver (Ag) |
| Coil Resistance | Not specified | 39.8 Ohms |
| Mounting Type | Not specified | Socketable |
| Termination Style | Not specified | Plug In, Quick Connect - 0.110" (2.8mm) |
Engineering Selection Recommendations
The MY4N-GS-R DC6 is the designated manufacturer-recommended substitute for the obsolete MY4N-GS DC6. Both components share identical core electrical specifications: 6VDC coil voltage, 4PDT contact configuration, and 250VAC/220VDC maximum switching voltage rating. Both maintain RoHS Compliance status, satisfying regulatory requirements.
The MY4N-GS-R DC6 offers the advantage of active product status, ensuring continued availability and manufacturer support. The socketable mounting design and documented electrical performance parameters (coil current, operate/release times, operating temperature range) provide enhanced design flexibility and system integration clarity compared to the obsolete variant.
Selection of the MY4N-GS-R DC6 is appropriate for applications requiring direct functional replacement of the MY4N-GS DC6, particularly in new designs or system upgrades where long-term component availability is a consideration.
Frequently Asked Questions (FAQ)
Q: Can the MY4N-GS-R DC6 directly replace the MY4N-GS DC6 in existing circuits?
A: Yes. Both relays share identical coil voltage (6VDC), contact form (4PDT), and maximum switching voltage (250VAC, 220VDC). The MY4N-GS-R DC6 is the manufacturer-recommended substitute and maintains functional equivalence for general purpose relay applications.
Q: What is the primary difference between these two part numbers?
A: The MY4N-GS-R DC6 features socketable mounting with plug-in termination, whereas the MY4N-GS DC6 mounting type is not specified. The substitute also includes mechanical and lighted indicator features and is classified as an active product, compared to the obsolete status of the original part.
Q: Are there packaging differences between these parts?
A: The MY4N-GS DC6 is listed with unspecified packaging, while the MY4N-GS-R DC6 is supplied in bulk packaging. Confirm packaging requirements with your procurement specifications.
Q: Do both relays meet RoHS compliance requirements?
A: Yes. Both the MY4N-GS DC6 and MY4N-GS-R DC6 are RoHS Compliant, satisfying regulatory requirements for restricted substance use.
Q: What coil current should be expected in circuit design?
A: The MY4N-GS-R DC6 operates at 151 mA coil current with a coil resistance of 39.8 Ohms. Use these specifications for power supply and control circuit calculations. The original MY4N-GS DC6 coil current is not documented.
Q: What is the operating temperature range for these relays?
A: The MY4N-GS-R DC6 operates across -40°C to 70°C. The operating temperature range for the MY4N-GS DC6 is not specified in available documentation.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts