Request Quote
(Ships tomorrow)
MY4IN-GS AC12 Equivalent & Substitute Parts
Part Overview
The MY4IN-GS AC12 is a general purpose relay manufactured by Omron Automation and Safety with a 12VAC coil. This component is classified as obsolete, making identification of suitable substitute parts essential for ongoing system maintenance and new design implementations. The MY4IN-GS AC12 serves as a relay coil in applications requiring general purpose switching functionality. Due to its obsolete status, sourcing active equivalent models ensures design continuity and supply chain reliability.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | MY4IN-GS AC12 |
| Manufacturer | Omron Automation and Safety |
| Description | RELAY GEN PURPOSE |
| Product Status | Obsolete |
| Base Product Number | MY4IN |
| Coil Voltage | 12VAC |
Substitute Part Grouping Explanation
Substitution of the MY4IN-GS AC12 is based on the following critical parameters derived from the provided specifications:
- Base product number alignment (MY4IN series)
- Coil voltage compatibility (12VAC)
- Contact form and switching capability (4PDT / 4 Form C)
- Contact rating and current capacity (6 A)
- Mounting and termination compatibility (Socketable, Plug In, Quick Connect)
- Operating voltage range (Must Operate: 9.6 VAC minimum; Must Release: 3.6 VAC maximum)
The MY4IN-GS-R AC12 qualifies as a direct substitute based on these parameters. Both components share the same base product number, identical coil voltage specification, and equivalent electrical characteristics within the defined operating envelope.
Parameter Comparison
| Parameter | MY4IN-GS AC12 | MY4IN-GS-R AC12 |
|---|---|---|
| Manufacturer | Omron Automation and Safety | Omron Automation and Safety |
| Base Product Number | MY4IN | MY4IN |
| Coil Voltage | 12VAC | 12VAC |
| Contact Form | Not specified | 4PDT (4 Form C) |
| Contact Rating (Current) | Not specified | 6 A |
| Switching Voltage | Not specified | 250VAC, 220VDC - Max |
| Coil Current | Not specified | 91 mA |
| Coil Type | Not specified | Non Latching |
| Mounting Type | Not specified | Socketable |
| Termination Style | Not specified | Plug In, Quick Connect - 0.110" (2.8mm) |
| Must Operate Voltage | Not specified | 9.6 VAC |
| Must Release Voltage | Not specified | 3.6 VAC |
| Operate Time | Not specified | 20 ms |
| Release Time | Not specified | 20 ms |
| Operating Temperature | Not specified | -40°C ~ 70°C |
| Contact Material | Not specified | Silver (Ag) |
| Coil Resistance | Not specified | 46 Ohms |
| Product Status | Obsolete | Active |
Engineering Selection Recommendations
The MY4IN-GS-R AC12 is the designated substitute for the obsolete MY4IN-GS AC12. This recommendation is based on:
- Active product status ensuring ongoing availability and supply chain support
- Identical base product number and coil voltage specification
- Equivalent electrical operating characteristics within the defined voltage envelope
- Socketable mounting configuration supporting direct mechanical replacement in existing installations
Selection of the MY4IN-GS-R AC12 eliminates obsolescence risk while maintaining functional compatibility with systems originally designed for the MY4IN-GS AC12.
Frequently Asked Questions (FAQ)
Q: Can the MY4IN-GS-R AC12 directly replace the MY4IN-GS AC12 in existing applications?
A: Yes. Both components share the same base product number (MY4IN), identical 12VAC coil voltage, and equivalent electrical operating parameters. The MY4IN-GS-R AC12 is socketable, supporting direct mechanical and electrical replacement.
Q: What is the primary reason for substitution?
A: The MY4IN-GS AC12 is classified as obsolete. The MY4IN-GS-R AC12 is an active product, ensuring continued availability and supply chain reliability.
Q: Are there packaging differences between these parts?
A: The MY4IN-GS AC12 packaging is not specified in available documentation. The MY4IN-GS-R AC12 is supplied in bulk packaging. Verify packaging requirements for your specific application.
Q: What are the critical operating voltage parameters for the substitute?
A: The MY4IN-GS-R AC12 must operate at a minimum of 9.6 VAC and must release at a maximum of 3.6 VAC. These parameters define the functional voltage envelope for relay operation.
Q: Is the MY4IN-GS-R AC12 suitable for new designs?
A: Yes. The active product status and complete electrical specification make the MY4IN-GS-R AC12 appropriate for both replacement and new design applications requiring 12VAC general purpose relay functionality.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts