The Omron MY4-GS DC48 is a general purpose relay featuring a 4PDT (4 Form C) contact configuration with a 48VDC coil. This relay is classified as obsolete, making identification of suitable substitute components essential for system maintenance, repair, and redesign applications. The MY4-GS series provides reliable switching capability for industrial control circuits requiring multiple independent switching paths.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Manufacturer Part Number | MY4-GS DC48 |
| Manufacturer | Omron Automation and Safety |
| Series | MY |
| Relay Type | General Purpose |
| Contact Form | 4PDT (4 Form C) |
| Coil Voltage | 48VDC |
| Switching Voltage | 250VAC, 220VDC - Max |
| Coil Type | Non Latching |
| Product Status | Obsolete |
| RoHS Status | RoHS Compliant |
| Moisture Sensitivity Level (MSL) | 1 (Unlimited) |
Substitute Part Grouping Explanation
The MY4-GS-R DC48 qualifies as a direct substitute for the MY4-GS DC48 based on the following critical parameters:
- Contact Configuration: Both parts maintain identical 4PDT (4 Form C) contact form
- Coil Voltage: Both operate at 48VDC
- Relay Type: Both are general purpose relays with non-latching coil type
- Switching Voltage Rating: Both support 250VAC and 220VDC maximum switching voltage
- Series Compatibility: Both belong to the Omron MY series
- Compliance: The substitute part maintains RoHS3 compliance, exceeding the original RoHS requirement
The primary distinction is the mounting configuration: the MY4-GS-R DC48 is socketable with plug-in quick connect termination, whereas the original MY4-GS DC48 mounting type is not specified. The substitute part is currently in active production status, ensuring long-term availability.
Parameter Comparison
| Parameter | MY4-GS DC48 (Original) | MY4-GS-R DC48 (Substitute) |
|---|---|---|
| Manufacturer Part Number | MY4-GS DC48 | MY4-GS-R DC48 |
| Manufacturer | Omron Automation and Safety | Omron Automation and Safety |
| Series | MY | MY |
| Relay Type | General Purpose | General Purpose |
| Contact Form | 4PDT (4 Form C) | 4PDT (4 Form C) |
| Coil Voltage | 48VDC | 48VDC |
| Switching Voltage | 250VAC, 220VDC - Max | 250VAC, 220VDC - Max |
| Coil Type | Non Latching | Non Latching |
| Product Status | Obsolete | Active |
| RoHS Status | RoHS Compliant | ROHS3 Compliant |
| Contact Rating (Current) | Not specified | 6 A |
| Coil Current | Not specified | 18.8 mA |
| Must Operate Voltage | Not specified | 38.4 VDC |
| Must Release Voltage | Not specified | 4.8 VDC |
| Operating Temperature | Not specified | -55°C ~ 70°C |
| Contact Material | Not specified | Silver (Ag) |
Engineering Selection Recommendations
The MY4-GS-R DC48 is the appropriate substitute for the obsolete MY4-GS DC48 based on the following factors:
- Product Continuity: The substitute part is in active production status, ensuring availability for current and future procurement cycles
- Compliance Enhancement: The MY4-GS-R DC48 meets ROHS3 compliance, providing improved environmental and regulatory alignment compared to the original RoHS Compliant designation
- Functional Equivalence: All critical electrical parameters—contact form, coil voltage, switching voltage, and coil type—are identical between the original and substitute parts
- Series Consistency: Both parts maintain the same Omron MY series designation, ensuring compatibility with existing relay base sockets and control circuit designs
Selection of the MY4-GS-R DC48 eliminates obsolescence risk while maintaining full functional compatibility with applications originally designed for the MY4-GS DC48.
Frequently Asked Questions (FAQ)
Q: Can the MY4-GS-R DC48 be used as a direct replacement for the MY4-GS DC48?
A: Yes. Both relays share identical contact form (4PDT), coil voltage (48VDC), switching voltage rating (250VAC, 220VDC max), and coil type (non-latching). The MY4-GS-R DC48 is the manufacturer-recommended substitute.
Q: What is the primary difference between these two relay models?
A: The MY4-GS-R DC48 features socketable mounting with plug-in quick connect termination (0.110" / 2.8mm), whereas the original MY4-GS DC48 mounting type is not specified. The substitute part also provides documented electrical specifications including coil current (18.8 mA), contact rating (6 A), and operating temperature range (-55°C ~ 70°C).
Q: Why is the original MY4-GS DC48 listed as obsolete?
A: The MY4-GS DC48 has reached end-of-life status in Omron's product portfolio. The MY4-GS-R DC48 represents the active production alternative within the same series.
Q: Are there any compliance differences between the two parts?
A: The MY4-GS DC48 carries RoHS Compliant status, while the MY4-GS-R DC48 meets the more stringent ROHS3 Compliant standard. Both parts satisfy environmental and regulatory requirements for industrial applications.
Q: What termination style does the substitute part use?
A: The MY4-GS-R DC48 uses plug-in quick connect termination with 0.110" (2.8mm) connectors, enabling rapid installation and removal from relay bases.
Q: Is the contact material specified for the original part?
A: The original MY4-GS DC48 contact material is not specified in the available documentation. The MY4-GS-R DC48 uses silver (Ag) contact material, which is standard for general purpose relays in this voltage and current class.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts