Request Quote
(Ships tomorrow)
Omron MY4-AC24 General Purpose Relay - Equivalent & Substitute Parts
Part Overview
The Omron MY4-AC24 is a general purpose 4PDT (4 Form C) relay with 24VAC coil voltage and 3A contact rating, designed for socketable mounting applications. This part is classified as obsolete, making equivalent and substitute parts necessary for ongoing system maintenance and new designs. The MY4-AC24 operates with 46mA coil current, 20ms operate/release times, and supports switching voltages up to 250VAC and 125VDC maximum.
Substiute Parts
Key Parameters
| Parameter | Value |
|---|---|
| Coil Voltage | 24VAC |
| Contact Form | 4PDT (4 Form C) |
| Contact Rating (Current) | 3 A |
| Switching Voltage | 250VAC, 125VDC - Max |
| Coil Current | 46 mA |
| Mounting Type | Socketable |
| Termination Style | Plug In |
| Operating Temperature Range | -55°C ~ 70°C |
| Contact Material | Silver (Ag) |
| Coil Resistance | 180 Ohms |
| Must Operate Voltage | 19.2 VAC |
| Must Release Voltage | 7.2 VAC |
Substitute Part Grouping Explanation
Substitute parts for the MY4-AC24 are classified based on the following critical parameters that determine functional compatibility:
Direct Equivalent (Identical Electrical and Mechanical Specifications):
- Coil voltage: 24VAC
- Contact form: 4PDT (4 Form C)
- Contact rating: 3A minimum
- Mounting type: Socketable
- Termination style: Plug In
- Operating temperature range: -55°C to 70°C minimum
- Must operate voltage: 19.2 VAC
- Must release voltage: 7.2 VAC
Parametric Equivalent (Same electrical function, minor specification variations allowed):
- Coil voltage: 24VAC
- Contact form: 4PDT (4 Form C)
- Mounting type: Socketable
- Termination style: Plug In
- Contact rating: 3A or higher
- Operating temperature range: -45°C to 70°C minimum
Similar Parts (Same contact form and coil voltage, higher current ratings or different contact materials):
- Coil voltage: 24VAC
- Contact form: 4PDT (4 Form C)
- Mounting type: Socketable
- Contact rating: 5A or 6A (suitable for applications requiring higher current capacity)
Parameter Comparison
| Parameter | MY4-AC24 | MY4 AC24 (S) | MY4Z AC24 (S) | KHAU-17A11-24 | KHAU-17A12-24 | PT570524 |
|---|---|---|---|---|---|---|
| Manufacturer | Omron | Omron | Omron | TE Connectivity | TE Connectivity | TE Connectivity |
| Product Status | Obsolete | Active | Active | Active | Active | Active |
| Coil Voltage | 24VAC | 24VAC | 24VAC | 24VAC | 24VAC | 24VAC |
| Contact Form | 4PDT | 4PDT | 4PDT | 4PDT | 4PDT | 4PDT |
| Contact Rating (Current) | 3 A | 3 A | 3 A | 3 A | 5 A | 6 A |
| Switching Voltage (Max) | 250VAC, 125VDC | 250VAC, 125VDC | 250VAC, 125VDC | 240VAC | 240VAC | 240VAC |
| Coil Current | 46 mA | 46 mA | 46 mA | 52 mA | 52 mA | Not Specified |
| Mounting Type | Socketable | Socketable | Socketable | Socketable | Socketable | Socketable |
| Termination Style | Plug In | Plug In | Plug In | Plug In | Plug In | Plug In, Quick Connect |
| Operating Temperature | -55°C ~ 70°C | -55°C ~ 70°C | -55°C ~ 70°C | -45°C ~ 70°C | -45°C ~ 70°C | -40°C ~ 70°C |
| Contact Material | Silver (Ag) | Silver (Ag) | Silver (Ag) | Silver (Ag) | Silver Cadmium Oxide (AgCdO) | Silver Nickel (AgNi) |
| Coil Resistance | 180 Ohms | 180 Ohms | 180 Ohms | 160 Ohms | 160 Ohms | 192 Ohms |
| Must Operate Voltage | 19.2 VAC | 19.2 VAC | 19.2 VAC | 20.4 VAC | 20.4 VAC | 19.2 VAC |
| Must Release Voltage | 7.2 VAC | 7.2 VAC | 7.2 VAC | Not Specified | Not Specified | 7.2 VAC |
| Operate Time | 20 ms | 20 ms | 20 ms | 13 ms | 13 ms | Not Specified |
| Release Time | 20 ms | 20 ms | 20 ms | 6 ms | 6 ms | Not Specified |
| RoHS Status | Not Specified | RoHS Compliant | RoHS Compliant | RoHS non-compliant | ROHS3 Compliant | ROHS3 Compliant |
| Packaging | Bulk | Bulk | Bulk | Tray | Tray | Bulk |
Engineering Selection Recommendations
For Direct Replacement (Obsolete Part Elimination): Select MY4 AC24 (S) or MY4Z AC24 (S) from Omron. Both parts are active products with identical electrical specifications to the MY4-AC24, including 3A contact rating, 24VAC coil voltage, 4PDT contact form, and socketable mounting. Both are RoHS compliant, addressing regulatory requirements for new designs and procurement.
For Higher Current Applications: KHAU-17A12-24 (5A rating) or PT570524 (6A rating) are suitable when the application requires contact ratings exceeding 3A. Both maintain 24VAC coil voltage, 4PDT contact form, and socketable mounting. KHAU-17A12-24 is ROHS3 compliant. PT570524 includes mechanical indicator and test button features with ROHS3 compliance.
For Extended Temperature Range: The MY4-AC24 operates from -55°C to 70°C. Substitute parts from TE Connectivity (KHAU series and PT570524) operate from -40°C to -45°C minimum, which may not be suitable for applications requiring the full -55°C lower temperature limit.
For Regulatory Compliance: MY4 AC24 (S) and MY4Z AC24 (S) are RoHS compliant. KHAU-17A11-24 is RoHS non-compliant and should not be selected for new designs subject to RoHS requirements. KHAU-17A12-24 and PT570524 are ROHS3 compliant.
Frequently Asked Questions (FAQ)
Q: Can MY4 AC24 (S) directly replace MY4-AC24? A: Yes. MY4 AC24 (S) is a direct equivalent with identical electrical and mechanical specifications, including 3A contact rating, 24VAC coil voltage, 4PDT contact form, socketable mounting, and plug-in termination. The primary difference is product status: MY4-AC24 is obsolete while MY4 AC24 (S) is active.
Q: What is the difference between MY4Z AC24 (S) and MY4 AC24 (S)? A: Both parts are parametric equivalents with identical electrical specifications. The difference lies in the base product number designation (MY4Z versus MY4), but all critical parameters including coil voltage, contact form, current rating, and operating characteristics are identical.
Q: Can KHAU-17A11-24 replace MY4-AC24 in all applications? A: KHAU-17A11-24 maintains the same 3A contact rating, 24VAC coil voltage, and 4PDT contact form. However, it has a higher must-operate voltage (20.4 VAC versus 19.2 VAC), faster switching times (13ms operate, 6ms release versus 20ms each), and operates only to -45°C (versus -55°C). It is also RoHS non-compliant. Verify application requirements before substitution.
Q: When should KHAU-17A12-24 or PT570524 be selected? A: These parts are suitable when the application requires higher contact current ratings (5A or 6A respectively) while maintaining 24VAC coil voltage and 4PDT contact form. Both are active products with RoHS compliance. PT570524 includes mechanical indicator and test button features.
Q: What packaging options are available? A: MY4-AC24, MY4 AC24 (S), MY4Z AC24 (S), and PT570524 are supplied in bulk packaging. KHAU-17A11-24 and KHAU-17A12-24 are supplied in tray packaging. Verify packaging requirements for procurement and assembly processes.
Q: Are there temperature range limitations when substituting? A: Yes. The MY4-AC24 operates from -55°C to 70°C. TE Connectivity substitutes (KHAU series) operate from -45°C minimum, and PT570524 operates from -40°C minimum. Applications requiring full -55°C operation must use Omron MY4 AC24 (S) or MY4Z AC24 (S).
Q: What is the coil resistance difference between substitutes? A: MY4-AC24, MY4 AC24 (S), and MY4Z AC24 (S) have 180 Ohm coil resistance. KHAU-17A11-24 and KHAU-17A12-24 have 160 Ohm coil resistance. PT570524 has 192 Ohm coil resistance. Verify circuit design compatibility when coil resistance differs.
Alternative Parts
SJ6012L2TP
Littelfuse Inc.
6 Alternative Parts
JMK107BBJ476MA-RE
Taiyo Yuden
10 Alternative Parts
GMK107BBJ475MA-T
Taiyo Yuden
5 Alternative Parts
SJ6020N2ARP
Littelfuse Inc.
3 Alternative Parts
SJ6025R2ATP
Littelfuse Inc.
4 Alternative Parts
2474-05L
API Delevan Inc.
1 Alternative Parts
4590R-684K
API Delevan Inc.
1 Alternative Parts
CM6560R-334
API Delevan Inc.
1 Alternative Parts
CM6460-104
API Delevan Inc.
1 Alternative Parts
5526-12
API Delevan Inc.
1 Alternative Parts