MY2N-GS-ML DC6 Equivalent & Substitute Parts

Part Overview

The MY2N-GS-ML DC6 is a general purpose relay manufactured by Omron Automation and Safety with a 6VDC coil. This component is classified as Obsolete, making identification of suitable substitute parts essential for ongoing system maintenance and new design implementations. The obsolete status necessitates sourcing of functionally equivalent alternatives to maintain operational continuity.

Substiute Parts

MY2N-GS-ML DC6
Omron Automation and SafetyIn Stock: 1168MY2N-GS-ML DC6 Datasheet
MY2N-GS-ML DC6
Current Part
MY2N-GS-R DC6
Omron Automation and SafetyIn Stock: 953MY2N-GS-R DC6 Datasheet
MY2N-GS-R DC6
MFR Recommended

Key Parameters

Parameter Value
Manufacturer Part Number MY2N-GS-ML DC6
Manufacturer Omron Automation and Safety
Description RELAY GEN PURPOSE
Product Status Obsolete
Base Product Number MY2N-GS
Series MY
Coil Voltage 6VDC

Substitute Part Grouping Explanation

Substitution of the MY2N-GS-ML DC6 is determined by the following critical parameters derived from the provided specifications:

  • Coil Voltage: 6VDC (must match exactly)
  • Relay Type: General Purpose
  • Manufacturer: Omron Automation and Safety (same manufacturer lineage)
  • Base Product Series: MY series compatibility

The substitute part MY2N-GS-R DC6 maintains these core electrical characteristics while offering Active product status, ensuring continued availability and manufacturer support.

Parameter Comparison

Parameter MY2N-GS-ML DC6 MY2N-GS-R DC6
Manufacturer Omron Automation and Safety Omron Automation and Safety
Description RELAY GEN PURPOSE RELAY GEN PURPOSE DPDT 5A 6V
Product Status Obsolete Active
Coil Voltage 6VDC 6VDC
Relay Type General Purpose General Purpose
Series MY MY
Contact Form - DPDT (2 Form C)
Contact Rating (Current) - 10 A
Switching Voltage - 250VAC, 220VDC - Max
Coil Current - 151 mA
Coil Type - Non Latching
Mounting Type - Socketable
Termination Style - Plug In, Quick Connect - 0.110" (2.8mm)
Coil Resistance - 39.8 Ohms
Must Operate Voltage - 4.8 VDC
Must Release Voltage - 0.6 VDC
Operate Time - 20 ms
Release Time - 20 ms
Operating Temperature - -40°C ~ 70°C
Contact Material - Silver (Ag)
Features - Lighted Indicator, Mechanical Indicator
Inventory Status 1062 Pcs New Original In Stock 858 Pcs New Original In Stock

Engineering Selection Recommendations

The MY2N-GS-R DC6 is the designated manufacturer-recommended substitute for the obsolete MY2N-GS-ML DC6. Both components share identical coil voltage specifications (6VDC) and belong to the same MY series general purpose relay family from Omron Automation and Safety. The substitute part maintains Active product status, ensuring manufacturer support, continued availability, and compliance with current supply chain requirements. Selection of the MY2N-GS-R DC6 is appropriate for applications requiring direct replacement of the obsolete MY2N-GS-ML DC6 variant.

Frequently Asked Questions (FAQ)

Q: What makes MY2N-GS-R DC6 a suitable substitute for MY2N-GS-ML DC6?

A: Both parts share the same 6VDC coil voltage, general purpose relay classification, and MY series designation from Omron Automation and Safety. The substitute maintains electrical compatibility while offering Active product status.

Q: Are there mechanical compatibility considerations between these parts?

A: The MY2N-GS-R DC6 features Socketable mounting with Plug In and Quick Connect termination (0.110" / 2.8mm). Verify that your application's socket and termination interface accommodate these specifications.

Q: What is the operational difference in coil current between these relays?

A: The MY2N-GS-R DC6 operates at 151 mA coil current with a coil resistance of 39.8 Ohms. Confirm that your power supply and control circuitry can deliver this current level.

Q: Why is the MY2N-GS-ML DC6 listed as Obsolete?

A: Obsolete status indicates the manufacturer has discontinued this specific variant. The MY2N-GS-R DC6 represents the current active equivalent within the MY2N-GS product line.

Q: Can I use MY2N-GS-R DC6 in existing designs without modification?

A: Direct substitution is possible if your application's socket, termination interface, and electrical requirements align with the specifications of the MY2N-GS-R DC6. Verify mounting type and termination style compatibility with your PCB or relay socket.